1 / 12

FIDA Diagnostic

FIDA Diagnostic. Diagnostic for FAST IONS : it measures the vertical component of perpendicular energy Processes generating fast ions Beam ICRH heating Nuclear reaction. beam + plasma ions. beam + plasma e. CXRS. Collisional ionization. beam ion. + beam. plasma neutrals

gates
Télécharger la présentation

FIDA Diagnostic

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FIDA Diagnostic Diagnostic for FAST IONS : it measures the vertical component of perpendicular energy Processes generating fast ions Beam ICRH heating Nuclear reaction

  2. beam + plasma ions beam + plasma e CXRS Collisional ionization beam ion + beam plasma neutrals (halo neutrals) CXRS Re- neutrals Beam-Plasma Interaction 2

  3. Da emission from neutrals

  4. Radiation signal Da from Re-neutrals ONLY signal to analyze

  5. PROTOTYPE INSTRUMENT Wavelenght range is  = 6470 - 6630 Å Spectral Resolution: 5 Å 5

  6. CONTAMINANTS IN THE SPECTRUM

  7. Fitting of a theoretical response function • The theoretical response function radiated by the impurity is the convolution of: • the Gaussian line shape radiated by the impurity • the instrumental response (taken by illuminating the fibers with a neon lamp and represented by the sum of three Gaussians)

  8. Spectrum from re-neutrals • Born by CXRS fast ions-beam • Not Maxwellain distribution function • Da spectrum much broader with a non- Gaussian shape

  9. Rotational velocity • Measurement vector with parallel and orthogonal direction to magnetic field • Doppler shift • Ion energy con • For view line orthogonal to B

  10. vz vz a) b) Fast ion Fast ion j B B For view line orthogonal to B • For vz = 2.4 106 m/s --> Ez = 60 KeV a) b) Any value of Any ion with energy

  11. The success of FIDA is based on • Vertical views ( Doppler shift only due to gyromotion of fast ions) • Blocking bar ( avoiding CCD saturation) • Beam modulation ( for substructing background) • High quantum efficiency CCD ( for good S/N)

  12. Spectrometers + CCD: characteristics

More Related