1 / 17

V. Egorov

V. Egorov. JINR + LSM. =. V. Egorov. The love story. 1991 Orsay S.Jullian and D.Lalanne proposed to bring our 2 β -spectrometer to Modane 1993 TGV . TGV-1 (1994 – 2000).

genero
Télécharger la présentation

V. Egorov

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. V. Egorov

  2. JINR+LSM = V. Egorov

  3. The love story • 1991 Orsay S.Jullian and D.Lalanne proposed to bring our 2β-spectrometer to Modane • 1993 TGV

  4. TGV-1 (1994 – 2000) • Stack of 16 HPGe planar detectors58mm (sensitive area = 12 cm2) Total area of samples  100 cm2 • 7 samples of natCa • 8 samples of enriched 48Ca: 1.08 g  1.35•1022 atoms CaCO3 ( 41 mg/cm2 ) • NIM A372 (1996) 222 $ 250 000

  5. TGV-1 results T1/2 (22) = =(2.97.5)•1019 y T1/2 (20)   1.5•1021 y (90%CL) Zero

  6. The love story • 1994 We had produced one (of two) scintillator wall for the NEMO-2 Started to prepare NEMO-3

  7. Participation of JINR in NEMO-3 • 6 tons of plastic scintillator (both internal and external walls) • Big-dimensional Cu and Fe details of the sectors • Fe shielding • Enriched isotopes: 48Ca 96Zr 150Nd • Mounting, cabling, tuning, … • Software for the data analysis • Calibration, analysis

  8. The love story • 2000 Dramatic upgrade of TGV (TGV-2)

  9. TGV-2(2000 – …)

  10. TGV-2 (2000 – …) • Stack of 32 HPGe planar detectors60 mm (sensitive area : 20 cm2) Total area of samples : 330 cm2 Total mass of sample(s) : 10  20 g Total efficiency : 40  50 % E-resolution : 3  4 keV @ 60Co LE-threshold : 40  50 keV (5  6 keV) • 16 samples of 48Ca (10 g) : 20 g CaF2 + CH2 ( 60 mg / cm2 ) • 16 samples of 106Cd: 10 g Cd( 30 mg / cm2 )

  11. Nuclei - candidates T1/2(5-forbidden ) 0.187% 1.25% 2 X-rays Purification procedure (ion-exchange technique). 20 g of 48Ca have been purified: k (Co, Ra, Eu) = (1.310)•103

  12. The love story • 2005 E.Yakushev → EDELWEISS

  13. Participation of JINR in EDELWIESS-2 • Background environment control - Rn detector - Low-background n-detectors (internal background ≈ 0.4 counts per day) • Assembling, commissioning, running(calibrations, tests, etc) • Direct beta calibrations(MC and interpretation)

  14. The love story • 2005 Super-Heavy In Nature (SHIN) looking for multi-neutron events • 2010 eka-Os → eka-Xe

  15. The love story (be continued) • NEMO → SuperNEMO (+BiPo) calorimeter calibration system software

  16. The love story (be continued) • TGV 2010: finish 2EC of 106Cd Search for Solar Axion with 57Fe • Low-threshold Ge detectors (coherent -e scattering, NMM, etc.) 2.9 – 3.0 keV threshold is not enough low… 250 g ~400 eV (→250 eV) 450 g stack Σ10 kg (TGV cryostat is perfectly suited for the low-background tests)

  17. Relic neutrino?...

More Related