1 / 14

Methanol and Ethanol Analysis/

Methanol and Ethanol Analysis/. J. Picker. The Ultimate Gourmet Martini. Objective. Analyze methanol and ethanol at 100-1000 ug/L or lower Use standard or modified EPA Methods Provide adequate Turnaround and pricing to meet client needs Make a profit.

genevieve
Télécharger la présentation

Methanol and Ethanol Analysis/

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Methanol and Ethanol Analysis/ J.Picker The Ultimate Gourmet Martini HP Labs Escondido, CA

  2. Objective • Analyze methanol and ethanol at 100-1000 ug/L or lower • Use standard or modified EPA Methods • Provide adequate Turnaround and pricing to meet client needs • Make a profit HP Labs Escondido, CA

  3. Warning • Methanol is “wood alcohol” minimum lethal dose 1g/kg but toxic effects as low as 10g. toxicity is due to metabolic production of formic acid • Ethanol is less toxic HP Labs Escondido, CA

  4. Problems • Very Poor purging efficiency (i.e., NO 5030/5035) • Allowed Prep. Techniques • 5031 Azeotropic distillation • 5032 Vacuum distillation • 5021 Equilibrium Headspace =nd • 5041 VOST train = nd • Direct Inject HP Labs Escondido, CA

  5. Problems II • Low sensitivity on FID and MS • Interferences by HCs and other compounds on FID HP Labs Escondido, CA

  6. HP Labs’ Solution • Direct Aqueous injection/EPA Method 8260B • GC Column and conditions to separate MeOH, EtOH from water • Stable Labeled isotope internal standards (CD3OH,CD3CH2OH) • Modified with Selected Ion Monitoring Mass Spectrometry (SIM) HP Labs Escondido, CA

  7. HP Labs Escondido, CA

  8. HP Labs Escondido, CA

  9. HP Labs Escondido, CA

  10. HP Labs Escondido, CA

  11. Sample Preparation: water • Sample Size 1 mL • Add Labeled IS Solution • Inject HP Labs Escondido, CA

  12. Sample Preparation: Soil • Ultrasonic extraction (EPA 3550) 10 g/10 mL • Remove 1mL • Add IS • Inject HP Labs Escondido, CA

  13. Detection LimitsWater and Soil • MDLs < 100 ug/L (ug/kg) • EQLs 250 ug/L (ug/kg) HP Labs Escondido, CA

  14. What This Means • Methanol and Ethanol on site or off site • Rapid turnaround • All levels of QC • Price as low as fixed base HP Labs Escondido, CA

More Related