690 likes | 1.81k Vues
Gie Cable Gland (Suryoday Enterprise) is a one of the leading Brass Double Cable Gland Manufacturers, Suppliers & Exporters in India, Based in Jamnagar, Gujarat.
E N D
SURYODAY ENTERPRISE CABLE GLANDS, CONNECTORS & CABLING ACCESSORIES
TM “Thinking Larger, Moving Faster” Creating The Momentum To Reach Our Goal. Momentum is defined as the energy of a moving body measured by its mass and speed. At Suryoday, we have combined extensive capabilities and development with an ability to move with remarkable speed and accuracy. In doing so, we have created a significant momentum. The Company Suryoday Enterprise, on the leading edge of technology, is Technical competence and creativity marks co-operation with SuryodayEnterprise(SEP) and their partners. engaged in manufacturing of cable glands & electrical accessories since last two decades. We are operating in steps with the advances of CNC technology, automated systems and advance manufacturing processes and techniques. Suryoday known in the Indian market as manufacturers of premium quality At SEP we embarked upon a massive restoration of our plant & its facilities during late 90's when sate-of-the-art machinery and testing equipment were acquired. Thereafter, new machines are recurrently being introduced to enhance our product capacity and product range. The new machines and equipment have numerous built-in functions and features assuring precision and consistency of the highest standard. products in the field of Electrical accessories. As a family business in the 2nd generation, we are well aware of the inter-relationships between creative ideas, their flexible realisation and partner-like dealings with employees, suppliers and customers. This leaves its mark on how we think and act. We provide backing for trusting co-operation on all levels. Doing this together, the upshot is success across the board, so that we are capable of maintaining ourselves in the global market. From the very first idea and then construction on state-of-the-art 3D CAD installations, from production on a flexible fleet of machines right up to on-time delivery,SEP does not leave anything to chance. It is our company goal to translate ideas that are ready to come into the market for cable gland management into quality products made of high-grade materials. To this end, we implement ecologically-friendly production processes and draw up detailed documentation on the products manufactured and the processes involved. This gives our customers the safety and reliable functioning they need. Our extensive experience, together with the latest technology enables us to manufacture Cable Glands which cover the whole spectrum of armoured and unarmoured cable and applications from general industrial through increased safety, deluge, flameproof and explosion proof. Our products have to be capable of withstanding mechanical stress and must reliably protect electrical installations from damp and dirt, so that power can flow without hindrance, thus providing complete solution of cable termination to the industry in both hazardous and non-hazardous area of electrical installations. The Cable Glands are available in Brass as standard with Stainless Steel, Aluminium and Plastic as an optional material on certain designs. An Ambitious Strategy While there is no defined path to success for any business, we firmly believe that there are certain principles that are essential: put the customer first, let their requirements be your guide, do the job right the first time and never allow conventional wisdom to stand in the way of innovation. GIE Cable Glands are designed, manufactured and tested to satisfy the demands of the various testing bodies and authorities like CIMFR (erstwhile CMRI) and others. AtSEP, we live these ideals daily, and we are committed to making our company one of the top in our industry. Our strategy for attaining this level of success, while ambitious, is simple. Simple, however, does not mean easy, and we understand the challenges that are ahead of us. Since our inception, we have worked diligently to assemble the team and technology we need to address those challenges and maintain our momentum. SEP is directly represented throughout INDIA by experienced partners, well known authorised dealers and distributors. This proximity leads to intensive talks with users from the most varied branches and markets. The results of such interchanges form the basis for our products and services of tomorrow.
TM Our Vision Our Values "Our vision has always been to excel in our performance and achieve perfection in what we are doing. Flawless production, timely delivery and competitive pricing are the characteristics of our organisation." To continuously improve our products and service, we believe that a perfect understanding of the clients need is of crucial importance and also adhere to the concept of corporate social responsibility. Quality Policy Suryoday Enterprise is committed to supply timely quality Our Commitment Our commitment is to understand and exceed the expectations of our valued customers, while delivering high quality product, services, and solutions to their most demanding requirements. product to our valued customers. We ensure to supply complaint free product to achieve complete customer satisfaction through continual improvement. Business Philosophy Our philosophy is to find the best engineering solution for the Health and Safety Policy SuryodayEnterprise firmly believes in its workplace being safe customer's particular requirement or requirements which results from hazards, and wants its employees to work in an injury-free in the creation of long standing commercial relationships built on mutual trust and understanding. SEP prides itself in having a very environment, produce safe and accurate products, commit to pollution prevention, and protect the natural environment. close working relationship with its customers and has a much focused market driven philosophy.
TM List of Contents Page 001 Field of Applications & Our Reputed Clients Page 002 Single Compression Heavy Duty Cable Glands Page 004 Double Compression Weather Proof Cable Glands Page 006 Double Compression Flame Proof (Gas Group I, IIA & IIB) Cable Glands Page 008 Double Compression Flame Proof (Gas Group IIC) Cable Glands Page 010 Single Compression Medium Duty Cable Glands Page 011 Double Compression Medium Duty Cable Glands Page 012 Flange Type Cable Glands Page 013 Other Types of Cable Glands Page 014 Accessories Page 016 Cable Glands Selection Chart for Unarmoured Power Cable Page 018 Cable Glands Selection Chart for Unarmoured Control Cable Page 019 Cable Glands Selection Chart for Armoured Power Cable Page 022 Cable Glands Selection Chart for Armoured Control Cable Page 023 Cable Glands Selection Chart on the Basis of Cable Overall Dia.
TM Field of Applications Electric Power Generation & Distribution Industries Control Panels, Switch gears, Transformers Mining Industries Cement Industries Iron & Steel Industries Petroleum Industries Chemical Industries Fertilizer Industries Sugar Industries Satellite & Communication Industries Aeronautic Industries Automobile Industries Railways Shipping Industries Textile Industries Defence Industries & Other Industries Page 01
Single Compression Heavy Duty Cable Glands TM Technical Data: Material Plating Entry Threads Sealing Rubber Ring Gland Standard Ingress Protection : Brass (IS-319) Standard (Al. / S.S. / M.S. also available) : Nickle Plated Standard (Chrome also available) : Metric threads with 1.5 pitch as per IS 4218 standard : Synthetic / Natural : IS 12943 : 1990 : IP 60 as per IS 12063 Application: Single Compression Glands are weather proof and dust proof (IP-60) which can be used in normal climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere. These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores. Designation: Single Compression Glands are designated as below : SCGn, where SC Single Compression G Gland n(n=1, 2,....20) Gland Size For eg.(SCG1, SCG2,...... SCG20) Accessories: PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately. Fitting Sequence: (a) Pass the Compression Nut (Part-5), one Metal Washer (Part-3) & Outer Seal Ring (Part-4) in succession order over the outer sheath of the cable before commencing to strip the cable (b) Remove the outer sheath to the desired length depending on the length of the beds required. (c) Pass the 2nd Metal Washer (Part-3) over the exposed armour and then splay out the armour wire one by one. Now cut the armour wire according to the size of the metal washer and bend the same. Pass the 3rd Metal Washer (Part-3) over the inner sheath and place it over the bended armour, so that the armour wires are now secured between the two Metal Washer. (d) Push the assembly through the Gland Body (Part-2) and tighten the Compression Nut (Part-5). While doing so the outer seal ring will expand in radial direction and will grip the cable. This will ensure dust proof entry of the cable. (e) Finally apply the fitted gland assembly to the extreme with the entry thread provided, if the enclosure does not have threaded entry than tight the gland assembly with the Check Nut (Part-1). Page 02
Single Compression Heavy Duty Cable Glands TM L1 D3 D5 D1 D2 D4 1 2 3 3 4 3 5 Check Nut Gland Body Metal Washer Metal Washer Outer Sealing Ring Metal Washer Compression Nut Size Code D1 Suitable Cable Overall Dia D2 Dia. D3 Dia. D4 (A/F) D5 (A/C) L1 Nipple Entry Threads in Metrics Length From To SCG mm Ø mm Ø mm mm mm mm 12.0 12.0 15.0 16.0 20.0 24.0 28.0 33.0 37.0 43.0 49.0 55.0 61.0 67.0 73.0 79.0 84.5 93.0 101.0 Tolerance ± 1mm 9.0 12.0 15.0 15.0 18.0 20.0 24.0 28.0 32.0 37.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 92.0 100.0 115.0 SCG 1 SCG 2 SCG 3 SCG 4 SCG 5 SCG 6 SCG 7 SCG 8 SCG 9 SCG 10 SCG 11 SCG 12 SCG 13 SCG 14 SCG 15 SCG 16 SCG 17 SCG 18 SCG 19 SCG 20 16 x 1.5 16 x 1.5 20 x 1.5 20 x 1.5 25 x 1.5 25 x 1.5 32 x 1.5 40 x 1.5 40 x 1.5 50 x 1.5 50 x 1.5 63 x 1.5 63 x 1.5 75 x 1.5 75 x 1.5 82 x 1.5 90 x 1.5 100 x 1.5 110 x 1.5 125 x 1.5 12.0 12.0 15.0 15.0 20.5 20.5 27.0 34.0 34.0 44.0 44.0 55.0 55.0 68.0 67.0 73.0 81.0 91.0 100.0 113.0 16.0 18.5 18.5 24.0 24.0 28.5 33.0 37.0 41.0 47.0 52.0 61.5 65.0 71.0 76.0 82.0 91.0 98.0 107.0 118.0 22.0 25.0 25.0 30.0 31.5 35.0 40.0 46.0 50.0 58.0 65.0 73.0 77.0 85.0 90.0 97.0 108.0 117.0 127.0 142.0 25.5 29.0 29.0 34.5 36.0 40.0 46.0 53.0 57.5 67.0 75.0 84.0 89.0 98.0 104.0 112.0 124.0 135.0 146.0 164.0 9.0 9.0 9.0 9.5 9.5 10.0 12.0 12.0 12.0 13.0 13.0 14.0 14.0 15.0 15.0 17.0 19.0 20.0 25.0 25.0 Page 03
Double Compression Weather Proof Cable Glands TM Technical Data: Material Plating Entry Threads Sealing Rubber Ring Gland Standard Ingress Protection : Brass (IS-319) Standard (Al. / S.S. / M.S. also available) : Nickle Plated Standard (Chrome also available) : BSC Standard (PG / Metric / NPT / BSP / also available) : Nitrile / Neoprene : BS 6121 : IP 66 as per IS 12063 Application: Weather Proof Double Compression Glands are weather proof and dust proof (IP-66) which can be used in normal climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere. These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores. Accessories: PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately. Fitting Sequence: (a) Insert Part No. 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour. (b) After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour. (c) Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it. (d) Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 9 with Part No. 7. (e) Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have threaded entry than tight the Gland with the Part No. 1 provided. Page 04
Double Compression Weather Proof Cable Glands TM B E A D F 3 1 2 4 5 6 7 8 9 C 1 2 3 4 5 6 7 8 9 Check Nut Entry Seal Ring Nipple Entry Part Inner Seal Ring Armour Clamping Cone Armour Clamping Ring Main Gland Body Outer Seal Ring Compression Nut Suitable Cable A B C D E F Overall Dia Code Nipple Entry Length (A/F) (A/C) Dia. Dia. From To MCW Series Inches mm mm mm Ø mm Ø mm Tolerance ± 1mm 6.0 12.0 16.5 16.5 18.5 18.5 20.0 23.0 23.0 26.0 26.0 30.0 30.0 33.0 37.0 41.0 46.0 46.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 12.0 16.5 18.5 18.5 20.0 20.0 23.0 26.0 26.0 30.0 30.0 33.0 33.0 37.0 41.0 46.0 52.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 104.0 MCW 01SS MCW 01S MCW 01 MCW 01A MCW 02 MCW 02A MCW 03 MCW 04 MCW 04A MCW 05 MCW 05A MCW 06 MCW 06A MCW 07 MCW 08 MCW 09 MCW 010 MCW 010A MCW 011S MCW 011 MCW 012 MCW 013A MCW 013 MCW 014 MCW 015 MCW 016 3/4" 3/4" 3/4" 1" 1" 3/4" 1" 1" 1.1/4" 1.1/4" 1.1/2" 1.1/2" 1.1/4" 1.1/2" 2" 2" 2" 2.1/2" 2.1/2" 2.1/2" 3" 3" 3.1/4" 3.1/2" 4" 4.1/2" 13.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 21.0 25.0 27.5 27.5 30.0 30.0 31.5 36.0 36.0 41.0 41.0 47.0 47.0 50.0 56.0 59.0 67.0 67.0 74.0 80.0 85.0 90.0 99.0 105.0 114.0 130.0 24.0 29.0 31.5 31.5 34.5 34.5 36.0 41.5 41.5 47.0 47.0 54.0 54.0 57.0 64.0 67.0 77.0 77.0 85.0 92.0 98.0 103.0 113.0 121.0 132.0 149.0 13.0 18.0 19.0 19.0 21.0 21.0 23.5 27.0 27.0 31.0 31.0 34.5 34.5 38.0 42.5 47.0 53.0 53.0 57.0 62.0 68.0 73.0 80.0 85.0 98.0 106.0 14.5 14.5 14.5 14.5 18.0 14.5 19.0 20.5 22.0 25.5 27.0 31.0 27.0 32.0 38.5 40.0 44.0 48.0 51.0 56.5 64.0 67.0 74.0 78.0 90.5 101.0 Page 05
Double Compression Flame Proof Cable Glands TM (Gas Group I, IIA & IIB) Technical Data: Material Plating Entry Threads Sealing Rubber Ring Gland Standard Ingress Protection : Brass (IS-319) Standard, (Al. / S.S. / M.S. also available) : Nickle Plated Standard, (Chrome also available) : BSC Standard (PG / Metric / NPT / BSP / also available) : Neoprene : BS 6121, IS 2148: 2004 : IP 65 as per IS 12063 - 1987 Application: Flame Proof Double Compression Glands are generally used in flammable gas / vapours area (for gas group I, IIA & IIB) as well as in normal climatic conditions also which are weather proof, water proof and dust proof (IP-65) which can be used in Hazardous climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere. These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores. Accessories: PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately. Fitting Sequence: (a) Insert Part No. 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour. (b) After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour. (c) Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it. (d) Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 9 with Part No. 7. (e) Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have threaded entry than tight the Gland with the Part No. 1 provided. Page 06
Double Compression Flame Proof Cable Glands TM (Gas Group I, IIA & IIB) B E A D F 3 1 2 4 5 6 7 8 9 C 1 2 3 4 5 6 7 8 9 Check Nut Neoprene Entry Seal Ring Nipple Entry Part Neoprene Inner Seal Ring Armour Clamping Cone Armour Clamping Ring Main Gland Body Neoprene Outer Seal Ring Compression Nut Suitable Cable Overall Dia MCF Code A B C D E F Nipple Entry Length (A/F) (A/C) Dia. Dia. From To MCF Series Inches mm mm mm Ø mm Ø mm 6.0 12.0 16.5 16.5 18.5 18.5 20.0 23.0 23.0 26.0 26.0 30.0 30.0 33.0 37.0 41.0 46.0 46.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 12.0 16.5 18.5 18.5 20.0 20.0 23.0 26.0 26.0 30.0 30.0 33.0 33.0 37.0 41.0 46.0 52.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 104.0 MCF 01SS MCF 01S MCF 01 MCF 01A MCF 02 MCF 02A MCF 03 MCF 04 MCF 04A MCF 05 MCF 05A MCF 06 MCF 06A MCF 07 MCF 08 MCF 09 MCF 010 MCF 010A MCF 011S MCF 011 MCF 012 MCF 013A MCF 013 MCF 014 MCF 015 MCF 016 3/4" 3/4" 3/4" 1" 1" 3/4" 1" 1" 1.1/4" 1.1/4" 1.1/2" 1.1/2" 1.1/4" 1.1/2" 2" 2" 2" 2.1/2" 2.1/2" 2.1/2" 3" 3" 3.1/4" 3.1/2" 4" 4.1/2" 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 21.0 25.0 27.5 27.5 30.0 30.0 31.5 36.0 36.0 41.0 41.0 47.0 47.0 50.0 56.0 59.0 67.0 67.0 74.0 80.0 85.0 90.0 99.0 105.0 114.0 130.0 24.0 29.0 31.5 31.5 34.5 34.5 36.0 41.5 41.5 47.0 47.0 54.0 54.0 57.0 64.0 67.0 77.0 77.0 85.0 92.0 98.0 103.0 113.0 121.0 132.0 149.0 13.0 18.0 19.0 19.0 21.0 21.0 23.5 27.0 27.0 31.0 31.0 34.5 34.5 38.0 42.5 47.0 53.0 53.0 57.0 62.0 68.0 73.0 80.0 85.0 97.0 106.0 14.5 14.5 14.5 14.5 18.0 14.5 19.0 20.5 22.0 25.5 27.0 31.0 27.0 32.0 38.5 40.0 44.0 48.0 51.0 56.5 64.0 67.0 74.0 78.0 90.5 101.0 Tolerance ± 1mm Page 07
Double Compression Flame Proof Cable Glands TM (Gas Group IIC) Technical Data: Material Plating Entry Threads Sealing Rubber Ring : Neoprene Gland Standard Standard Ref. : Brass (IS-319) Standard (Al. / S.S. / M.S. also available) : Nickle Plated Standard (Chrome also available) : BSC Standard (PG / Metric / NPT / BSP / also available) : BS 6121 : (a) As to general requirement IS:13346-2004 (b) As to flameproof construction IS:2148:2004 (c) As to weatherproof construction IP-65: IS:12063-1987 Application: Flame Proof Double Compression Glands are generally used in hydrogen gas/vapours area (for gas group IIC) as well as in normal climatic conditions also which are weather proof, water proof and dust proof (IP-65) which can be used in Hazardous climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere. These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores. Accessories: PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately. Fitting Sequence: (a) Insert Part No. 10, 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour. (b) After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour. (c) Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it. (d) Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 10 with Part No. 7. (e) Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have thread than tight the Gland with the Part No. 1 provided. Page 08
Double Compression Flame Proof Cable Glands TM (Gas Group IIC) L1 L2 D2 D1 D C1 3 1 2 4 5 6 7 8 9 10 C 1 2 3 4 5 6 7 8 9 10 Check Nut Neoprene Entry Seal Ring Nipple Entry Part Neoprene Inner Seal Ring Armour Armour Clamping Ring Main Gland Body Neoprene Outer Seal Ring Nylon Skid Washer Compression Nut Clamping Cone Suitable Cable D1 D2 L1 L2 C D C1 Overall Dia Code Nipple Entry Dia. Length Length (A/F) (A/C) Dia. From To MCF IIC Series Inches Ø mm mm mm mm mm Ø mm 6.0 12.0 16.5 16.5 18.5 18.5 20.0 23.0 23.0 26.0 26.0 30.0 30.0 33.0 37.0 41.0 46.0 46.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 12.0 16.5 18.5 18.5 20.0 20.0 23.0 26.0 26.0 30.0 30.0 33.0 33.0 37.0 41.0 46.0 52.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 104.0 MCF IIC 01SS MCF IIC 01S MCF IIC 01 MCF IIC 01A MCF IIC 02 MCF IIC 02A MCF IIC 03 MCF IIC 04 MCF IIC 04A MCF IIC 05 MCF IIC 05A MCF IIC 06 MCF IIC 06A MCF IIC 07 MCF IIC 08 MCF IIC 09 MCF IIC 010 MCF IIC 010A MCF IIC 011S MCF IIC 011 MCF IIC 012 MCF IIC 013A MCF IIC 013 MCF IIC 014 MCF IIC 015 MCF IIC 016 3/4" 3/4" 3/4" 1" 1" 3/4" 1" 1" 1.1/4" 1.1/4" 1.1/2" 1.1/2" 1.1/4" 1.1/2" 2" 2" 2" 2.1/2" 2.1/2" 2.1/2" 3" 3" 3.1/4" 3.1/2" 4" 4.1/2" 13.0 18.0 19.0 19.0 21.0 21.0 23.5 27.0 27.0 31.0 31.0 34.5 34.5 38.0 42.5 47.0 53.0 53.0 57.0 62.0 68.0 73.0 80.0 85.0 97.0 106.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 21.0 25.0 27.5 27.5 30.0 30.0 31.5 36.0 36.0 41.0 41.0 47.0 47.0 50.0 56.0 59.0 67.0 67.0 74.0 80.0 85.0 90.0 99.0 105.0 114.0 130.0 24.0 29.0 31.5 31.5 34.5 34.5 36.0 41.5 41.5 47.0 47.0 54.0 54.0 57.0 64.0 67.0 77.0 77.0 85.0 92.0 98.0 103.0 113.0 121.0 132.0 149.0 14.5 14.5 14.5 14.5 18.0 14.5 19.0 20.5 22.0 25.5 27.0 31.0 27.0 32.0 38.5 40.0 44.0 48.0 51.0 56.5 64.0 67.0 74.0 78.0 90.5 101.0 Tolerance ± 1mm Page 09
Single Compression Medium Duty Cable Glands TM Technical Data: Material Plating Entry Threads Sealing Rubber Ring : Natural : Brass : Nickle Plated : BSC Standard (Metric also available) Application: Used in normal climatic condition for armoured & unarmoured cables. L1 D3 D5 D1 D2 D4 Check Nut Gland Body Metal Washer Outer Metal Washer Compression Nut Sealing Ring Suitable Cable Overall Dia Size D1 D2 Dia. D3 Dia. D4 (A/F) D5 (A/C) L1 Nipple Entry Length From To mm inches Inches Ø mm Ø mm mm mm mm 12.0 14.0 16.0 18.0 21.5 26.0 31.0 34.0 38.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 6.0 9.0 9.0 12.0 14.0 16.0 18.0 21.5 26.0 31.0 34.0 38.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 92.0 10 12 16 19 22 25 28 32 35 38 45 50 57 63 70 75 82 88 100 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 5/8" 5/8" 3/4" 3/4" 3/4" 1" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 12.0 12.5 15.0 15.0 15.0 21.0 24.5 27.0 29.5 33.0 38.5 45.0 51.0 57.0 63.0 69.0 76.0 77.0 90.5 12.5 15.5 16.0 18.0 20.5 23.5 27.5 31.5 35.5 38.0 44.5 52.0 57.5 63.0 69.0 75.0 81.5 84.0 99.0 18.0 20.5 20.5 23.0 25.0 28.5 33.0 37.0 42.0 45.0 52.0 58.0 65.0 70.0 77.0 83.0 90.5 96.0 110.0 20.5 23.5 23.5 26.0 29.0 32.5 38.0 43.0 48.0 52.0 60.0 67.0 75.0 81.0 89.0 96.0 104.0 110.0 126.0 7.0 7.0 7.0 * 7.0 * 7.0 * 8.0 * 8.5 * 11.0 * 11.0 * 11.0 * 11.0 * 11.0 * 13.0 13.5 13.5 13.5 14.0 15.0 16.0 2" 2" 2 1/4" 2 1/2" 2 3/4" 2 1/4" 2 1/2" 2 3/4" 3" 3" 3 1/4" 3 1/2" 3 1/4" 3 1/2" 4" 4" Page 10 * Gland body with long nipple length also available | Tolerance ± 1mm
Double Compression Medium Duty Cable Glands TM Technical Data: Material Plating Entry Threads Sealing Rubber Ring : Natural : Brass : Nickle Plated : BSC Standard (Metric / NPT also available) Application: Used in normal climatic condition for armoured & unarmoured cables. Armour Clamping Ring Entry Seal Ring Inner Seal Ring Outer Seal Ring B E A D F Nipple Entry Part Check Nut Armour Clamping Cone Main Compression Nut Gland Body C Suitable Cable Overall Dia Size A B C D E F Nipple Entry Length (A/F) (A/C) Dia. Dia. From To mm inches Inches mm mm mm Ø mm Ø mm 12.0 16.5 18.5 20.0 23.0 26.0 30.0 33.0 37.0 41.0 46.0 52.0 54.0 61.0 72.0 78.0 84.0 Tolerance ± 1mm 6.0 6.0 9.0 12.0 16.5 18.5 20.0 23.0 26.0 30.0 33.0 37.0 41.0 46.0 52.0 54.0 61.0 72.0 78.0 84.0 94.0 10 12 16 19 22 25 28 32 35 38 45 50 57 63 70 75 82 88 100 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 5/8" 5/8" 3/4" 3/4" 3/4" 1" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 20.5 23.0 23.0 25.5 28.0 31.5 35.5 41.0 44.0 46.0 57.0 61.0 67.0 79.0 82.0 90.0 95.0 106.0 116.0 23.5 26.0 26.0 29.5 32.0 36.0 41.0 47.0 50.5 53.0 65.5 70.5 77.0 91.0 95.0 105.0 109.0 123.0 135.0 10.0 13.5 16.5 19.0 20.0 23.5 27.0 32.0 35.0 38.0 44.5 51.0 57.0 63.0 69.5 75.0 82.0 88.0 98.0 7.0 11.0 14.0 14.0 14.0 19.0 22.5 25.5 27.5 31.0 42.0 42.0 50.0 54.5 62.0 65.0 74.5 78.0 87.0 2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 2 1/4" 2 1/2" 2 3/4" 3" 3" 3 1/4" 3 1/2" 3 1/4" 3 1/2" 4" 4" Page 11
Flange Type Cable Glands TM E Check Nut L Gland Plate M.S. Nut Gland Body Taper Cone M.S. Stud Technical Data: Size E L Suitable Cable Overall Dia. Material Finish Entry Threads : Brass : Brass : ET / BSC Dia. Length Code Ø mm mm From To FL 5 FL 4 FL 3 FL 2 FL 1 FL 11 FL 0 FL 00 FL 38 FL 001 FL 002 FL 003 FL 0033 FL 004 FL 005 15.0 19.0 19.5 25.0 31.0 31.0 37.5 37.5 42.0 49.0 53.5 60.0 65.0 75.0 99.0 13.0 13.0 13.0 16.5 15.5 15.0 21.0 20.0 21.5 20.5 21.5 23.0 25.5 22.5 22.5 12.0 15.0 18.5 20.5 24.0 29.5 32.5 34.5 37.0 40.5 43.5 51.0 56.5 66.0 75.0 16.5 19.0 20.5 24.5 30.0 34.0 35.0 38.0 42.0 44.0 52.0 58.0 67.0 76.0 83.0 Application: Generally for armoured cable and outdoor use. Flange Type Cable Glands are made out of brass castings and are machined accurately to the required sizes. These glands are suitable for armoured cables and are called mechanical glands hence suitable for outdoor application. The gland comprises of brass body ( flange type oval shape ) and plate clamped with galvanised mild steel studs and nuts for clamping the armour. Tapered cone and nut are provided for termination of cable. The cone and body taper is designed for giving a firm grip to the armour of the cable. Tolerance ± 1mm Page 12
Other Types of Cable Glands TM PG Type Cable Glands Wiping Glands BW Type Cable Glands A1/A2 Type Cable Glands CW Type Cable Glands Alco Type Cable Glands E1W Type Cable Glands Marine Type Cable Glands Page 13
Accessories TM Stopping Plug GIE Range of Stopping plugs are designed to close any unused entries of an electrical equipments without revoking existing certification. The range covers three design types: Material Plating Threads Sealing Rubber Ring : Neoprene Ref. Standard Ingress Protection : Brass (IS - 319) Standard (Al. / M.S. / S.S. also available) : Nickle Plated - Standard (Chrome also available) : BSC - Standard (PG / Metric / NPT / BSP also available) Flame Proof Stopping Plug : IS 2148 : 2004 : IP 65 as per IS 12063 - 1987 Application Size (MCS) : Used in flammable gas vapour area. (Group I, IIA & IIB) : 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3" Weather Proof Stopping Plug Material Plating Threads Application Size : Brass (IS - 319) Standard : Nickle Plated - Standard (Chrome also available) : BSC - Standard (PG / Metric / NPT / BSP also available) : Used in normal climatic condition. : 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3" Tamper Proof Stopping Plug Material Plating Threads Application Size : Brass (IS - 319) Standard : Nickle Plated - Standard (Chrome also available) : BSC - Standard (PG / Metric / NPT / BSP also available) : Used to prevent unauthorised removal. : 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3" Adaptor GIE Adaptors provide a means of connection between dissimilar thread forms or sizes. Material Plating Threads Application : Brass (IS - 319) Standard : Nickle Plated - Standard (Chrome also available) : BSC - Standard (PG / Metric / NPT / BSP also available) : Used in normal climatic condition. Page 14
Accessories TM Reducer GIE Reducers effectively reduce the threaded entry diameter of an enclosure to accept a gland or fitting with a smaller thread. The range covers two design types: Material Plating Threads Sealing Rubber Ring : Neoprene Ref. Standard Ingress Protection : Brass (IS - 319) Standard (Al. / M.S. / S.S. also available) : Nickle Plated - Standard (Chrome also available) : BSC - Standard (PG / Metric / NPT / BSP also available) Flame Proof Reducer : IS 2148 : 2004 : IP 65 as per IS 12063 - 1987 Application Size (MCR) : Used in flammable gas vapour area. (Group I, IIA & IIB) : 1" x 3/4", 1 1/4" x 1", 1 1/2" x 1 1/4", 2" x 1 1/2", 2 1/2" x 2" , 3" x 2 1/2" Weather Proof Reducer Material Plating Threads Application Size : Brass (IS - 319) Standard : Nickle Plated - Standard (Chrome also available) : BSC - Standard (PG / Metric / NPT / BSP also available) : Used in normal climatic condition. : 1" x 3/4", 1 1/4" x 1", 1 1/2" x 1 1/4", 2" x 1 1/2", 2 1/2" x 2" , 3" x 2 1/2" Earth Tag GIE Earth Tag ensures earthing continuity between Gland and Enclosure. Material Plating Application : Brass : Nickle Plated : Used with cable gland, adaptor & reducer to provide a means of conneting a flexible earth bond. PVC Shroud GIE PVC Shroud are used for covering the Cable Glands as additional protection against weather conditions and corrosion. Material Application : PVC : Minimises the risk of dirt or foreign substances gathering on the cable gland body and / or point of cable to the gland interface. Page 15
Cable Glands Selection Chart TM For Unarmoured Single Core Power Cables Type AYY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Inches Size Inches 1 x 4 1 x 6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 1 x 400 1 x 500 1 x 630 1 x 800 1 x 1000 8.3 8.8 9.7 11.5 12.5 14.0 15.5 17.0 19.5 21.5 23.5 25.5 28.5 32.0 36.0 40.0 45.0 49.0 54.0 3/8" 3/8" 1/2" 5/8" 3/4" 3/4" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2" 2 1/4" 2 1/2" 5/8" 5/8" 5/8" 5/8" 3/4" 3/4" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2" 2 1/4" 2 1/2" SCG 1 SCG 1 SCG 1 SCG 2 SCG 3 SCG 3 SCG 5 SCG 5 SCG 5 SCG 7 SCG 7 SCG 7 SCG 8 SCG 8 SCG 10 SCG 10 SCG 12 SCG 12 SCG 13 16 16 16 16 20 20 25 25 25 32 32 32 40 40 50 50 63 63 63 MCW 01SS MCW 01SS MCW 01SS MCW 01S MCW 01S MCW 01S MCW 01A MCW 01A MCW 02 MCW 03A MCW 04A MCW 04A MCW 05A MCW 06 MCW 07A MCW 08 MCW 09 MCW 010A MCW 011S MCF 01SS MCF 01SS MCF 01SS MCF 01S MCF 01S MCF 01S MCF 01A MCF 01A MCF 02 MCF 03A MCF 04A MCF 04A MCF 05A MCF 06 MCF 07A MCF 08 MCF 09 MCF 010A MCF 011S 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 28 mm 1 1/4" 1 1/4" 1 1/2" 1 1/2" 42 mm 2" 2" 2 1/2" 2 1/2" 3/8" 3/8" 1/2" 5/8" 3/4" 3/4" 3/4" 7/8" 7/8" 1" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" For Unarmoured Twin Core Power Cables Type AYY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Inches Size Inches 2 x 4 2 x 6 2 x 10 2 x 16 2 x 25 2 x 35 2 x 50 2 x 70 2 x 95 2 x 120 2 x 150 2 x 185 2 x 240 2 x 300 2 x 400 2 x 500 2 x 630 14.0 15.0 17.0 20.0 22.0 24.0 27.0 28.5 32.0 33.0 36.0 40.0 45.0 50.0 55.0 62.0 69.0 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" SCG 3 SCG 3 SCG 5 SCG 5 SCG 7 SCG 7 SCG 7 SCG 8 SCG 8 SCG 8 SCG 10 SCG 10 SCG 12 SCG 12 SCG 13 SCG 14 SCG 16 20 20 25 25 32 32 32 40 40 40 50 50 63 63 63 75 82 MCW 01S MCW 01A MCW 01A MCW 02 MCW 03A MCW 04A MCW 05A MCW 05A MCW 06 MCW 06 MCW 07A MCW 08 MCW 09 MCW 010A MCW 011 MCW 012 MCW 013A MCF 01S MCF 01A MCF 01A MCF 02 MCF 03A MCF 04A MCF 05A MCF 05A MCF 06 MCF 06 MCF 07A MCF 08 MCF 09 MCF 010A MCF 011 MCF 012 MCF 013A 3/4" 1" 1" 1" 28 mm 1 1/4" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 42 mm 2" 2" 2 1/2" 2 1/2" 3" 3" 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 3/8" 1 3/4" 1.3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" Page 16
Cable Glands Selection Chart TM For Unarmoured Three Core Power Cables Type AYY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 3 x 150 3 x 185 3 x 240 3 x 300 3 x 400 3 x 500 3 x 630 15.0 16.0 17.5 21.0 22.0 23.5 27.5 31.0 35.0 37.0 41.0 45.0 51.5 58.0 65.0 74.0 79.0 3/4" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 2" 2" 2 1/2" 2 3/4" 3" 3 1/4" 3 1/2" 3/4" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 2" 2" 2 1/2" 2 3/4" 3" 3 1/4" 3 1/2" SCG 3 SCG 5 SCG 5 SCG 5 SCG 7 SCG 7 SCG 8 SCG 8 SCG 10 SCG 10 SCG 10 SCG 12 SCG 12 SCG 14 SCG 14 SCG 16 SCG 17 20 25 25 25 32 32 40 40 50 50 50 63 63 75 75 82 90 MCW 01A MCW 01A MCW 01A MCW 03A MCW 03A MCW 04A MCW 05A MCW 06 MCW 07A MCW 08 MCW 08 MCW 09 MCW 010A MCW 012 MCW 012 MCW 013 MCW 014 MCF 01A MCF 01A MCF 01A MCF 03A MCF 03A MCF 04A MCF 05A MCF 06 MCF 07A MCF 08 MCF 08 MCF 09 MCF 010A MCF 012 MCF 012 MCF 013 MCF 014 1" 1" 1" 28 mm 28 mm 1 1/4" 1 1/2" 1 1/2" 42 mm 2" 2" 2" 2 1/2" 3" 3" 3 1/4" 3 1/2" 3/4" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 2" 2" 2 1/2" 2 3/4" 3" 3 1/4" 3 1/2" 3/4" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/2" 1 1/2" 2" 2" 2" 2" 2 1/2" 2 3/4" 3" 3 1/4" 3 1/2" For Unarmoured Three & Half Core Power Cables Type AYY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Inches Size Inches 3 1/2x25/16 3 1/2x35/16 3 1/2x50/25 3 1/2x70/35 3 1/2x95/50 3 1/2x120/70 3 1/2x150/70 3 1/2x185/95 3 1/2x240/120 3 1/2x300/150 3 1/2x400/185 3 1/2x500/240 3 1/2x630/300 24.0 25.0 29.0 33.0 38.0 41.0 44.0 50.0 57.0 63.0 70.0 80.0 87.0 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" 4" 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" 4" SCG 7 SCG 7 SCG 8 SCG 8 SCG 10 SCG 10 SCG 11 SCG 12 SCG 14 SCG 14 SCG 16 SCG 17 SCG 18 32 32 40 40 50 50 50 63 75 75 82 90 100 MCW 04A MCW 04A MCW 05A MCW 06 MCW 08 MCW 08 MCW 09 MCW 010A MCW 012 MCW 012 MCW 013 MCW 014 MCW 015 MCF 04A MCF 04A MCF 05A MCF 06 MCF 08 MCF 08 MCF 09 MCF 010A MCF 012 MCF 012 MCF 013 MCF 014 MCF 015 1 1/4" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2 1/2" 3" 3" 3 1/4" 3 1/2" 4" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" 4" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" 4" Page 17
Cable Glands Selection Chart TM For Unarmoured Four Core Power Cables Type AYY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches 4 x 4 4 x 6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 4 x 120 4 x 150 4 x 185 4 x 240 4 x 300 4 x 400 16.0 18.0 19.0 23.5 24.0 27.0 32.0 36.0 41.0 43.0 48.0 53.0 59.0 66.0 74.0 1" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 1" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" SCG 5 SCG 5 SCG 5 SCG 7 SCG 7 SCG 7 SCG 8 SCG 10 SCG 10 SCG 10 SCG 12 SCG 12 SCG 14 SCG 14 SCG 16 25 25 25 32 32 32 40 50 50 50 63 63 75 75 82 MCW 01A MCW 01A MCW 02 MCW 04A MCW 04A MCW 05A MCW 06 MCW 07A MCW 08 MCW 09 MCW 010A MCW 011S MCW 012 MCW 012 MCW 013 MCF 01A MCF 01A MCF 02 MCF 04A MCF 04A MCF 05A MCF 06 MCF 07A MCF 08 MCF 09 MCF 010A MCF 011S MCF 012 MCF 012 MCF 013 1" 1" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 42 mm 2" 2" 2 1/2" 2 1/2" 3" 3" 3 1/4" 1" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/4" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 1" 1" 1" 1 1/8" 1 1/4" 1 1/4" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" For Unarmoured 1.5 sq. mm. Multi Core Control Cables Type YY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 6 x 1.5 7 x 1.5 10 x 1.5 12 x 1.5 14 x 1.5 16 x 1.5 19 x 1.5 24 x 1.5 27 x 1.5 30 x 1.5 37 x 1.5 44 x 1.5 52 x 1.5 61 x 1.5 11.5 12.0 13.0 14.0 15.0 15.5 17.0 17.5 18.5 19.5 21.0 24.0 24.5 25.5 27.0 30.5 33.0 34.0 1/2" 5/8" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 5/8" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 3/4" SCG 2 SCG 3 SCG 3 SCG 3 SCG 3 SCG 5 SCG 5 SCG 5 SCG 5 SCG 5 SCG 7 SCG 7 SCG 7 SCG 7 SCG 7 SCG 8 SCG 8 SCG 9 16 20 20 20 20 25 25 25 25 25 32 32 32 32 32 40 40 40 MCW 01SS MCW 01S MCW 01S MCW 01S MCW 01A MCW 01A MCW 01A MCW 01A MCW 02 MCW 02 MCW 03A MCW 04A MCW 04A MCW 04A MCW 05A MCW 06 MCW 06 MCW 07A MCF 01SS MCF 01S MCF 01S MCF 01S MCF 01A MCF 01A MCF 01A MCF 01A MCF 02 MCF 02 MCF 03A MCF 04A MCF 04A MCF 04A MCF 05A MCF 06 MCF 06 MCF 07A 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1" 28 mm 1 1/4" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 42 mm 1/2" 5/8" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 3/4" 5/8" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 2" Page 18
Cable Glands Selection Chart TM For Unarmoured 2.5 sq. mm. Multi Core Control Cables Type YY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area Heavy Duty (SCG) as per IS 12943 Nipple Entry Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric BS 6121 Medium Duty Nipple Entry for Medium Duty for for of Cable Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Size Inches 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 6 x 2.5 7 x 2.5 10 x 2.5 12 x 2.5 14 x 2.5 16 x 2.5 19 x 2.5 24 x 2.5 27 x 2.5 30 x 2.5 37 x 2.5 44 x 2.5 52 x 2.5 61 x 2.5 13.0 13.5 14.5 15.5 17.0 17.5 19.5 20.5 22.0 23.0 24.0 28.0 28.5 29.5 33.0 35.0 37.0 39.0 5/8" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" SCG 3 SCG 3 SCG 3 SCG 3 SCG 5 SCG 5 SCG 5 SCG 5 SCG 7 SCG 7 SCG 7 SCG 8 SCG 8 SCG 8 SCG 8 SCG 10 SCG 10 SCG 10 20 20 20 20 25 28 25 25 32 32 32 40 40 40 40 50 50 50 MCW 01S MCW 01S MCW 01S MCW 01A MCW 01A MCW 01A MCW 02 MCW 02 MCW 03A MCW 03A MCW 04A MCW 05A MCW 05A MCW 05A MCW 06 MCW 07A MCW 08 MCW 08 MCF 01S MCF 01S MCF 01S MCF 01A MCF 01A MCF 01A MCF 02 MCF 02 MCF 03A MCF 03A MCF 04A MCF 05A MCF 05A MCF 05A MCF 06 MCF 07A MCF 08 MCF 08 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 28 mm 28 mm 1 1/4" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 42 mm 2" 2" 5/8" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/4" 1 3/4" 2" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" For Armoured Single Core Power Cables Type AYFY & AYWY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Sectional Area of Cable Heavy Duty (SCG) as per IS 12943 Nipple Entry Flange Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per in Metric Type BS 6121 Nipple Entry for Medium Duty Medium Duty for for Duty Medium Duty IS 2148 WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 1 x 4 1 x 6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 225 1 x 240 1 x 300 1 x 400 1 x 500 1 x 630 1 x 800 1 x 1000 12.3 12.8 13.5 15.0 16.0 17.0 19.0 20.0 22.0 24.0 25.0 27.0 30.0 33.0 35.0 39.0 41.0 45.0 52.0 55.0 5/8" 5/8" 5/8" 3/4" 3/4" 7/8" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" SCG 2 SCG 2 SCG 2 SCG 3 SCG 3 SCG 4 SCG 5 SCG 5 SCG 6 SCG 6 SCG 6 SCG 7 SCG 8 SCG 8 SCG 9 SCG 10 SCG 10 SCG 11 SCG 12 SCG 13 16 16 16 20 20 20 25 25 25 25 25 32 40 40 50 50 50 50 63 63 FL 5 FL 5 FL 5 FL 5 FL 5 FL 5 FL 4 FL 3 FL 2 FL 2 FL 1 FL 1 FL 11 FL 11 FL 00 FL 38 FL 001 FL 002 FL 003 FL 003 MCW 01S MCW 01S MCW 01S MCW 01S MCW 01S MCW 01 MCW 02 MCW 02 MCW 03 MCW 04 MCW 04 MCW 05 MCW 05 MCW 06 MCW 07 MCW 08 MCW 08 MCW 09 MCW 010 MCW 011 MCF 01S MCF 01S MCF 01S MCF 01S MCF 01S MCF 01 MCF 02 MCF 02 MCF 03 MCF 04 MCF 04 MCF 05 MCF 05 MCF 06 MCF 07 MCF 08 MCF 08 MCF 09 MCF 010 MCF 011 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2" 2 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" Page 19
Cable Glands Selection Chart TM For Armoured Twin Core Power Cables Type AYFY & AYWY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Sectional Area of Cable Nipple Entry for Medium Duty Heavy Duty (SCG) as per IS 12943 Flange Type Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per BS 6121 IS 2148 Nipple Entry for Medium Duty Nipple Entry in Metric Medium Duty for Duty WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 2 x 4 2 x 6 2 x 10 2 x 16 2 x 25 2 x 35 2 x 50 2 x 70 2 x 95 2 x 120 2 x 150 2 x 185 2 x 240 2 x 300 2 x 400 17.5 18.5 20.0 22.5 25.0 27.0 29.0 31.0 33.0 34.0 38.0 41.0 46.0 51.0 57.0 3/4" 7/8" 1" 1" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 3/8" 1 1/2" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 3/8" 1 1/2" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" SCG 4 SCG 5 SCG 5 SCG 5 SCG 6 SCG 7 SCG 8 SCG 8 SCG 8 SCG 9 SCG 9 SCG 10 SCG 11 SCG 12 SCG 13 20 25 25 25 25 32 40 40 40 40 40 50 50 63 63 FL 4 FL 4 FL 3 FL 2 FL 1 FL 1 FL 11 FL 11 FL 11 FL 11 FL 00 FL 001 FL 002 FL 003 FL 003 MCW 01 MCW 01 MCW 02 MCW 03 MCW 04 MCW 05 MCW 05 MCW 06 MCW 06 MCW 07 MCW 08 MCW 08 MCW 09 MCW 010 MCW 011 MCF 01 MCF 01 MCF 02 MCF 03 MCF 04 MCF 05 MCF 05 MCF 06 MCF 06 MCF 07 MCF 08 MCF 08 MCF 09 MCF 010 MCF 011 3/4" 3/4" 1" 1" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2" 2 1/2" 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 3/8" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 3/4" 3/4" 1" 1" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" For Armoured Three Core Power Cables Type AYFY & AYWY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Sectional Area of Cable Nipple Entry for Medium Duty Heavy Duty (SCG) as per IS 12943 Flange Type Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per BS 6121 IS 2148 Nipple Entry for Medium Duty Nipple Entry in Metric Medium Duty for Duty WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 3 x 150 3 x 185 3 x 240 3 x 300 3 x 400 3 x 500 18.0 19.5 21.0 23.5 24.0 25.5 29.0 33.0 37.0 39.0 43.0 47.0 53.0 59.0 66.0 76.0 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" SCG 5 SCG 5 SCG 5 SCG 6 SCG 6 SCG 7 SCG 8 SCG 9 SCG 9 SCG 10 SCG 11 SCG 11 SCG 12 SCG 13 SCG 14 SCG 16 25 25 25 25 25 32 40 40 40 50 50 50 63 63 75 82 FL 4 FL 3 FL 3 FL 2 FL 1 FL 1 FL 1 FL 0 FL 00 FL 38 FL 001 FL 002 FL 003 FL 003 FL 0033 FL 004 MCW 01 MCW 02 MCW 03 MCW 04 MCW 04 MCW 04 MCW 05 MCW 06 MCW 07 MCW 08 MCW 09 MCW 010 MCW 011S MCW 011 MCW 012 MCW 01 MCF 01 MCF 02 MCF 03 MCF 04 MCF 04 MCF 04 MCF 05 MCF 06 MCF 07 MCF 08 MCF 09 MCF 010 MCF 011S MCF 011 MCF 012 MCF 013 3/4" 1" 1" 1" 1" 1" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2 1/2" 2 1/2" 3" 3 1/4" 3/4" 7/8" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 3/4" 3/4" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" Page 20
Cable Glands Selection Chart TM For Armoured Three & Half Core Power Cables Type AYFY & AYWY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Nipple Entry Heavy Duty Sectional Area of Cable Duty Flange Type Weather Proof Flame Proof Nipple Entry Medium Nipple Entry (MCW) as per (MCF) as per BS 6121 IS 2148 WP . & FLP . Nipple Entry in Metric for (SCG) as per IS 12943 for for Duty Medium Duty Medium Duty No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 3 1/2x25/16 3 1/2x35/16 3 1/2x50/25 3 1/2x70/35 3 1/2x95/50 3 1/2x120/70 3 1/2x150/70 3 1/2x185/95 3 1/2x240/120 3 1/2x300/150 3 1/2x400/185 3 1/2x500/240 26.0 27.0 31.0 34.0 39.0 42.0 47.0 52.0 58.0 65.0 72.0 82.0 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" SCG 7 SCG 7 SCG 8 SCG 9 SCG 10 SCG 10 SCG 11 SCG 12 SCG 13 SCG 14 SCG 15 SCG 17 32 32 40 40 50 50 50 63 63 75 75 90 FL 1 FL 11 FL 11 FL 00 FL 38 FL 001 FL 002 FL 002 FL 003 FL 0033 FL 004 FL 005 MCW 04 MCW 05 MCW 06 MCW 07 MCW 08 MCW 09 MCW 010 MCW 010 MCW 011 MCW 012 MCW 013A MCF 013A MCW 014 MCF 04 MCF 05 MCF 06 MCF 07 MCF 08 MCF 09 MCF 010 MCF 010 MCF 011 MCF 012 1" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2" 2 1/2" 3" 3" 3 1/2" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/2" MCF 014 For Armoured Four Core Power Cables Type AYFY & AYWY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Sectional Area of Cable Nipple Entry for Medium Duty Heavy Duty (SCG) as per IS 12943 Flange Type Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per BS 6121 IS 2148 Nipple Entry for Medium Duty Nipple Entry in Metric Medium Duty for Duty WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 4 x 4 4 x 6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 4 x 120 4 x 150 4 x 185 4 x 240 4 x 300 4 x 400 19.0 20.5 21.5 25.5 26.0 28.0 33.0 37.0 42.0 45.0 50.0 55.0 62.0 68.0 76.0 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" SCG 5 SCG 5 SCG 6 SCG 6 SCG 7 SCG 7 SCG 8 SCG 9 SCG 10 SCG 11 SCG 12 SCG 13 SCG 14 SCG 15 SCG 16 25 25 25 25 32 32 40 40 50 50 63 63 75 75 82 FL 3 FL 3 FL 2 FL 1 FL 1 FL 11 FL 11 FL 00 FL 001 FL 002 FL 002 FL 003 FL 0033 FL 0033 FL 004 MCW 02 MCW 02 MCW 03 MCW 04 MCW 04 MCW 05 MCW 06 MCW 07 MCW 09 MCW 09 MCW 010 MCW 011 MCW 012 MCW 013A MCW 013 MCF 02 MCF 02 MCF 03 MCF 04 MCF 04 MCF 05 MCF 06 MCF 07 MCF 09 MCF 09 MCF 010 MCF 011 MCF 012 MCF 013A MCF 013 1" 1" 1" 1" 1" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2" 2 1/2" 3" 3" 3 1/4" 7/8" 7/8" 1" 1 1/8" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 3/4" 3/4" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/2" 1 1/2" 2" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" Page 21
Cable Glands Selection Chart TM For Armoured 1.5 sq. mm. Multi Core Control Cables Type YWY / YFY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Sectional Area of Cable Nipple Entry for Medium Duty Heavy Duty (SCG) as per IS 12943 Flange Type Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per BS 6121 IS 2148 Nipple Entry for Medium Duty Nipple Entry in Metric Medium Duty for Duty WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 6 x 1.5 7 x 1.5 10 x 1.5 12 x 1.5 14 x 1.5 16 x 1.5 19 x 1.5 24 x 1.5 27 x 1.5 30 x 1.5 37 x 1.5 44 x 1.5 52 x 1.5 61 x 1.5 15.0 15.5 16.0 16.5 17.0 17.5 20.5 21.0 21.5 21.5 22.0 25.5 26.0 27.0 29.0 33.0 34.0 36.0 5/8" 5/8" 3/4" 7/8" 7/8" 7/8" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" SCG 3 SCG 3 SCG 3 SCG 4 SCG 4 SCG 4 SCG 5 SCG 5 SCG 5 SCG 5 SCG 5 SCG 6 SCG 6 SCG 7 SCG 7 SCG 8 SCG 9 SCG 9 20 20 20 20 20 20 25 25 25 25 25 25 25 32 32 40 40 40 FL 5 FL 5 FL 5 FL 4 FL 4 FL 4 FL 3 FL 3 FL 2 FL 2 FL 2 FL 1 FL 1 FL 1 FL 1 FL 11 FL 0 FL 00 MCW 01S MCW 01S MCW 01S MCW 01S MCW 01 MCW 01 MCW 02 MCW 03 MCW 03 MCW 03 MCW 03 MCW 04 MCW 04 MCW 05 MCW 05 MCW 06 MCW 07 MCW 07 MCF 01S MCF 01S MCF 01S MCF 01S MCF 01 MCF 01 MCF 02 MCF 03 MCF 03 MCF 03 MCF 03 MCF 04 MCF 04 MCF 05 MCF 05 MCF 06 MCF 06 MCF 07 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 5/8" 5/8" 3/4" 3/4" 7/8" 7/8" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 1/2" 1 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" For Armoured 2.5 sq. mm. Multi Core Control Cables Type YWY / YFY 650 / 1100 V Cable Specifications Single Compression Type Double Compression Type Cores & Cross Overall Dia. Medium Sectional Area of Cable Nipple Entry for Medium Duty Heavy Duty (SCG) as per IS 12943 Flange Type Weather Proof Flame Proof Nipple Entry (MCW) as per (MCF) as per BS 6121 IS 2148 Nipple Entry for Medium Duty Nipple Entry in Metric Medium Duty for Duty WP . & FLP . No. Approx. Size Inches Size Code mm Size Code Size Code Size Code Size Size Inches 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 6 x 2.5 7 x 2.5 10 x 2.5 12 x 2.5 14 x 2.5 16 x 2.5 19 x 2.5 24 x 2.5 27 x 2.5 30 x 2.5 37 x 2.5 44 x 2.5 52 x 2.5 61 x 2.5 16.5 17.0 17.5 17.8 19.0 19.5 22.0 22.0 23.5 24.5 25.5 29.5 30.0 32.0 34.0 37.0 38.0 40.0 3/4" 3/4" 7/8" 7/8" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" SCG 3 SCG 4 SCG 4 SCG 4 SCG 5 SCG 5 SCG 5 SCG 5 SCG 6 SCG 6 SCG 6 SCG 7 SCG 7 SCG 8 SCG 9 SCG 9 SCG 10 SCG 10 20 20 20 20 25 25 25 25 25 25 25 32 32 40 40 40 50 50 FL 5 FL 5 FL 4 FL 4 FL 3 FL 3 FL 2 FL 2 FL 2 FL 2 FL 2 FL 1 FL 1 FL 1 FL 11 FL 00 FL 38 FL 38 MCW 01S MCW 01 MCW 01 MCW 01 MCW 02 MCW 02 MCW 03 MCW 03 MCW 04 MCW 04 MCW 04 MCW 05 MCW 05 MCW 06 MCW 07 MCW 07 MCW 08 MCW 08 MCF 01S MCF 01 MCF 01 MCF 01 MCF 02 MCF 02 MCF 03 MCF 03 MCF 04 MCF 04 MCF 04 MCF 05 MCF 05 MCF 06 MCF 07 MCF 07 MCF 08 MCF 08 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 2" 2" 3/4" 3/4" 7/8" 7/8" 7/8" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 1 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1 1/8" 1 1/8" 1 1/8" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 2" 2" Page 22
Cable Glands Selection Chart TM On The Basis of Cable Overall Diameter For Armoured Cables For Armoured Cables Single Compression Heavy Duty SCG Series as per IS12943 Single Compression Medium Duty Type Cable Overall Dia. (mm) Suitable for Suitable Gland Type Old SIBG Nipple Thread in Metric Cable Overall Dia. (mm) Suitable for Suitable Gland Type and Thread From 9.0 12.0 12.0 15.0 16.0 20.0 24.0 28.0 33.0 37.5 43.0 49.0 55.0 61.0 67.0 73.0 79.0 84.5 93.0 101.0 To 12.0 15.0 15.0 18.0 20.0 24.0 28.0 32.0 37.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 92.0 100.0 115.0 Code -- (1616) (1619) (2119) (2125) (2925) (2932) (2938) (3638) (4251) (5451) (5463) (6063) (6675) -- (7882) -- -- -- -- mm 16 x 1.5 16 x 1.5 20 x 1.5 20 x 1.5 25 x 1.5 25 x 1.5 32 x 1.5 40 x 1.5 40 x 1.5 50 x 1.5 50 x 1.5 63 x 1.5 63 x 1.5 75 x 1.5 75 x 1.5 82 x 1.5 90 x 1.5 100 x 1.5 110 x 1.5 125 x 1.5 From 6.0 9.0 12.0 14.0 16.0 18.0 21.5 26.0 31.0 34.0 38.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 To 9.0 12.0 14.0 16.0 18.0 21.5 26.0 31.0 34.0 38.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 92.0 Size 3/8" 1/2" 5/8" 3/4" 7/8" Size Code SCG 1 SCG 2 SCG 3 SCG 4 SCG 5 SCG 6 SCG 7 SCG 8 SCG 9 SCG 10 SCG 11 SCG 12 SCG 13 SCG 14 SCG 15 SCG 16 SCG 17 SCG 18 SCG 19 SCG 20 1" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 2 3/4" 3" 3 1/4" 3 1/2" 4" For Unarmoured Cables For Armoured Cables For Double Compression Weather Proof & Flame Proof Cable Glands For Double Compression Weather Proof & Flame Proof Cable Glands Cable Overall Dia. (mm) Suitable for Weather Proof as per BS 6121 Flame Proof as per IS 2148 Nipple Thread Cable Overall Dia. (mm) Suitable for Weather Proof as per BS 6121 Flame Proof as per IS 2148 Nipple Thread From To Size Code Size Code Size From To Size Code Size Code Size 5.0 11.0 14.1 18.1 20.1 23.1 26.1 30.1 33.1 36.1 41.1 44.1 52.1 55.1 60.1 66.1 75.0 81.0 90.0 11.0 14.0 18.0 20.0 23.0 26.0 30.0 33.0 36.0 41.0 44.0 52.0 55.0 60.0 66.0 75.0 80.0 90.0 100.0 MCW 01SS MCW 01S MCW 01A MCW 02 MCW 03A MCW 04A MCW 05A MCW 06 MCW 07A MCW 08 MCW 09 MCW 010A MCW 011S MCW 011 MCW 012 MCW 013 MCW 014 MCW 015 MCW 016 MCF 01SS MCF 01S MCF 01A MCF 02 MCF 03A MCF 04A MCF 05A MCF 06 MCF 07A MCF 08 MCF 09 MCF 010A MCF 011S MCF 011 MCF 012 MCF 013 MCF 014 MCF 015 MCF 016 3/4" 3/4" 1" 1" 12.0 16.5 16.5 18.5 18.5 20.0 23.0 23.0 26.0 26.0 30.0 30.0 33.0 37.0 41.0 46.0 46.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 6.0 12.0 16.5 18.5 18.5 20.0 20.0 23.0 26.0 26.0 30.0 30.0 33.0 33.0 37.0 41.0 46.0 52.0 52.0 54.0 61.0 66.0 72.0 78.0 84.0 94.0 104.0 MCW 01SS MCW 01S MCW 01 MCW 01A MCW 02 MCW 02A MCW 03 MCW 04 MCW 04A MCW 05 MCW 05A MCW 06 MCW 06A MCW 07 MCW 08 MCW 09 MCW 010 MCW 010A MCW 011S MCW 011 MCW 012 MCW 013A MCW 013 MCW 014 MCW 015 MCW 016 MCF 01SS MCF 01S MCF 01 MCF 01A MCF 02 MCF 02A MCF 03 MCF 04 MCF 04A MCF 05 MCF 05A MCF 06 MCF 06A MCF 07 MCF 08 MCF 09 MCF 010 MCF 010A MCF 011S MCF 011 MCF 012 MCF 013A MCF 013 MCF 014 MCF 015 MCF 016 3/4" 3/4" 3/4" 1" 1" 3/4" 1" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/4" 1 1/2" 28 mm 1 1/4" 1 1/2" 1 1/2" 42 mm 2" 2" 2 1/2" 2 1/2" 70 mm 3" 2" 2" 2" 3 1/4" 3 1/2" 4" 2 1/2" 2 1/2" 2 1/2" 4 1/2" 3" 3" 3 1/4" 3 1/2" 4" 4 1/2" Page 23
We reserve the right to make technical changes without notice. While we have done our best to ensure the accuracy of catalogue data, we take no responsibility for printing or other errors. For further inquiries contact: SURYODAY ENTERPRISE Office: K1,74/7,G.I.D.C.,Udyognagar,ShankerTekri, Jamnagar-361004,Gujarat(INDIA). E-mail:kamaniashish@gmail.com Phone : +91-288-2560764 Mob : +91 9099 408448 Web:www.suryodayent.co.in www.suryodayent.com