一种带有馈线保护功能的 PON 网络在线监测方案

一种带有馈线保护功能的 PON 网络在线监测方案. XIAO Tianlei 2011.9.25. 提纲. 设计目的 当前进展 设计方案 实验结果. 设计目的. 保证提供的服务 质量 馈线 段故障对整个系统影响较大 快速 准确的 故障定位 减少维护时间和成本,减少用户损失 在线监测的 必要性 察觉隐患,预防链路发生故障. 当前进展.

gina
Télécharger la présentation

一种带有馈线保护功能的 PON 网络在线监测方案

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 一种带有馈线保护功能的PON网络在线监测方案 XIAO Tianlei 2011.9.25

  2. 提纲 • 设计目的 • 当前进展 • 设计方案 • 实验结果

  3. 设计目的 • 保证提供的服务质量 • 馈线段故障对整个系统影响较大 • 快速准确的故障定位 • 减少维护时间和成本,减少用户损失 • 在线监测的必要性 • 察觉隐患,预防链路发生故障

  4. 当前进展 • Urban, P.J.; Dahlfort, S., “OTM- and OTDR-based cost-efficient Fiber Fault Identification and Localization in Passive Optical Network”, Optical Fiber Communication Conference and Exposition (OFC/NFOEC) and the National Fiber Optic Engineers Conference, pp. 1-3, 2011.

  5. 当前进展 • Honda, N.; Iida, D.; Izumita, H.; Azuma, Y., “In-Service Line Monitoring System in PONs Using 1650-nm Brillouin OTDR and Fibers With Individually Assigned BFSs”, Lightwave Technology, vol. 27 ,no. 20, pp. 4575– 4582, 2009.

  6. 当前进展 • Ng Boon Chuan; Premadi, A.; Ab-Rahman, M.S.; Jumari, K., “Physical Layer Monitoring in 8-branched PON-based i-FTTH”, International Conference on Photonics (ICP 2010), pp.1-5, 2010.

  7. 当前进展 • JongHoon Lee; Jung-Hyung Moon; Ki-Man Choi; Chang-Hee Lee, “Seamless Maintenance and Protection Scheme for Next-Generation Access Networks”, IEEE Photonics Technology Letters, vol. 21, no. 12, pp. 799-801, 2009

  8. 设计方案

  9. 设计方案 • 可以对当前链路进行在线监测 • 通过远端供电和远程控制,保证无端节点RN的无源性 • 提供了对馈线段的保护

  10. 设计方案 正常情况下: 数据信号 测试信号 控制信号

  11. 设计方案 故障情况下: 数据信号 测试信号 控制信号

  12. 实验结果 • 控制单元(单片机)的响应时间为10.7ms,机械光开关切换时间为8ms。所以可以保证保护的切换时间小于20ms。 • 通过仿真,测试光对各ONU的BER的影响很小,可以忽略,这保证了在线监测的可行性。