1 / 38

Mezentsev Nikolay Budker Institute of Nuclear Physics

Relevant experience with superconducting wigglers at BINP and plans for supercconducting undulators. Mezentsev Nikolay Budker Institute of Nuclear Physics. Content Introduction Three groups of SC wigglers High field wigglers Medium field wigglers Short period wigglers

glynn
Télécharger la présentation

Mezentsev Nikolay Budker Institute of Nuclear Physics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Relevant experience with superconducting wigglers at BINP and plans for supercconductingundulators Mezentsev Nikolay Budker Institute of Nuclear Physics Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  2. Content • Introduction • Three groups of SC wigglers • High field wigglers • Medium field wigglers • Short period wigglers • Comparison of horizontal and vertical racetrack coils • Horizontal racetrack type magnetic structure for undulator application • Wiggler cryogenic systems • Magnetic measurements systems for SC magnets • Resumeand future plans Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  3. Introduction The history of manufacturing and application of superconducting multipole magnetic systems in Budker INP has been started in 1979 – the year of creation of the first superconducting multipole wiggler (“snake”) ( B=3.5T and period of 9 cm) and its installation on the VEPP-3 storage ring as a powerful x-ray source. The magnet system of the first superconducting 20-pole wiggler (“snake”) (1979) The first superconducting 20-pole wiggler (“snake”), assembled with cryostat, before installation on the ring (1979) Undulator radiation from the first superconducting 20-pole wiggler (“snake”), (1979) For the period more than 30 years Budker INP has storedthe wide experience on creation of superconducting multipole magnetic systems – superconducting wigglersand shifters, used as generators of synchrotron radiation (SR) in many international centresof synchrotronradiations. Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  4. List of SC multipole wigglers, fabricated by Budker INP Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  5. 3 groups of SC multipole wiggler The superconducting wigglers may be divided into three groups according to their use. High field (7-7.5 T) and long period (150-200 mm) wigglers. This type of the wigglers are installing on SR sources with relative low electron energy on purpose to expand a photon energy range to more hard X-ray. As a rule one wiggler may give a SR beam for 3 or more independent beamlines. This kind of the wiggler to be installed on a storage ring with electron energy of 6-8 GeV can give the chance to development of new researches, including possibility of creation of bright sources of positrons and neutrons. (On SR sources with electron energy 1-2 GeV it also can be used as a source of terahertz undulator radiations). Half of the long period SC multipolewigglerfor the CAMD LSU (USA). B0 =7.5 Tesla, 0~200 mm) After installation of the wiggler on the CAMD ring (The wiggler behind group). (May, 2013) Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  6. Long period, high field SC multipole wigglers (B0 =7-7.5 Tesla, 0~150-200 mm) Moscow, Siberia-2,2007 21-pole SC wiggler Field 7.5 T Pole gap 20.2 mm Period 164 mm BESSY, Germany 2002 2013 cryostat upgrade 17-pole, SC wiggle Field 7T Pole gap 19 mm Period 148 mm CAMD LSU, USA 2013 15pole SC wiggler Field 7.5 T Pole gap 25.2 mm Period 193 mm Low photon energy spectrum of 7.5 T wiggler at CAMD 1.35 GeV (K=148) Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  7. Medium period and medium field SC multipole wigglers (B0=2.5-4.5 Tesla, 0~48-60 mm) • It makes sense to use two section windings for wigglers with a period more than 48 mm thus it is possible to receive increase in a field at 15%, feeding different sections with different currents according to the behaviour of the SC wire critical curve. Magnetic pole of superconducting wiggler magnet T=3.2K B=4.2T B=4 T T=4.2K Cross section of two sections pole Load lines of pole sections and critical curves of SC wire for different temperatures Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  8. Medium period and medium field SC multipole wigglers (B0=2.5-4.5 Tesla, 0~48-60 mm) DLS, England, 2006 49-poleSC wiggler Field 3.5Т Pole gap 16 mm Period 58.5 mm DLS, England, 2008 49-pole SC wiggler Field 4.2Т Pole gap 14.4 mm Period 47 mm CLS, Canada, 2007 27-pole SC wiggler Field 4.2 Т Pole gap 14.5 mm Period 48 mm LNLS, Brasil, 2009 35-pole SC wiggler Field 4.2Т Pole gap 18.4 mm Period 60 mm ASHo, Australia 2013 63-pole SC wiggler Field 4..2 Т Pole gap 15.2 mm Period 50.5 mm ELETTRA, Italy, 2002 2013 cryostat upgrade 49-pole SC wiggler Field 3.5 T Pole gap 16.5 mm Period 64 mm KIT, Germany, 2014 40-pole SC wiggler Field 2.5 T Pole gap 19 mm Period 47 mm Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  9. Short period SC multipole wigglers (B0 =2-2.2 Tesla, 0~30-35 mm) CLS, Canada, 2004 63-pole SC wiggler Field 2.2 T Pole gap 13.5 mm Average period 35 mm Assembly of ½ of the wiggler. In order to destroy periodicity between poles special spacers were installed in random order to destroy undulator spectrum in photon energy range 6-10 keV In spite of the small bending radius of the SC wire (3 mm) the current-carrying property of the wire was not lost. Calculated spectrum without random spacers Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  10. 2.1 Tesla 119-pole superconducting wiggler ALBA-CELLS (Spain) MaterialsScienceandPowderDiffraction (MSPD) beamline ALBA,Spain, 2010 119-pole SC wiggler Field 2.2 Т Pole gap 12.4 mm Period 30 mm The wiggler installed on ALBA ring Assembled superconducting multipole wiggler for ALBA ring X-ray beam from the wiggler Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  11. 2.1 Tesla 119-pole superconducting wiggler ALBA-CELLS (Spain) Sketch of the main pole of the wiggler ½ of the SC magnet Main magnetic element of the magnet Spectrum photon flux through 1x1 mm^2 at 30m Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  12. 2.1 Tesla 119-pole superconducting wiggler ALBA-CELLS (Spain) First field integral (angle) behavior at 2.1 T Longitudinal field distribution at set field 2.1 T Spatial spectrum of the magnetic field distribution at 2.1 T Second field integral (coordinate) behavior at 2.1 T Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  13. Interpolation formula for the fabricated planar, horizontal racetrack SC wigglers Figure shows the dependance of maximum magnetic field versus gap/λ by the interpolating curve and experimental data of different SC wigglers listed in the table above. The region which we have a plan to master in the nearest future First SC multipole wiggler 1979 Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  14. Comparison of horizontal and vertical racetrack coils Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  15. Horizontal racetrack type magnetic structure for undulator application • Horizontal racetrack coils assembly allows : • to pre-stress all coils together for compensation of magnetic pressure • to use 2 or more sections coils, which gives a possibility to obtain higher field for the same SC wire. • There is no limitation of pole number • Minimal period of an undulator is about 12 mm with use SC wire diameter of 0.5 mm • Large number of splices does not increase heat in-leak if to use cold welding method of wire connections Magnet array of horizontal racetrack type poles (example of 30 mm period SC 2.1T wiggler) Cold welding method of wires connection gives resistance of the connection10-10- 10-13 Ohm Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  16. Superconducting multipole magnet system with indirect cooling Electrical and heat sink commutation Assembling of the poles on the iron yoke Main pole with heat sink Assembled magnet before vacuum chamber installing Assembled magnet Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  17. Wiggler cryogenic system The primary goal of the cryostat design is to create reliable safe systems with the possibility of long term independent work with close to zero liquid helium consumption. Stages with temperature ~50К of all cryocoolers are used for cooling the external shield screen intercepting of heat coming through the electron vacuum chamber, radiation from the warm walls of the housing and heat coming from normal conducting current leads due to their heat conductivity and Joule heat. Horizontal bath cryostat for a wiggler magnet InordertoprovidezeroliquidHeconsumptionfour 2-stage cryocoolersareusedsymmetricallysituatedrelativelyofthewigglerends. ThebasiccryostatistopreventofanyheattopenetrateintotheliquidHetankinterceptingitbyheatsinksconnectedtothecryocoolersstages. Twocryocoolerswithstagesof 4К and 50К (type 1) andtwocryocoolerswithstagesof 10К and 50К (type 2) areusedforthisaim. Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  18. Cryostat for SC magnet with indirect cooling Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  19. Current leads block The cryocoolers with 4K stage are assembled together with the current leads block, consisting of a normal conducting part and high-temperature superconductors (HTSC) Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  20. Vacuum chamber and copper liner The second stages of the cryocoolers with 20K stage are used for cooling down of 20К shield screen and for interception of released heat in the copper liner when the electron beam is passing through the liner. Cross section of cold vacuum chamber with copper liner inside (bath cryostat version) Copper liner assembled with vacuum chamber Copper liner with ULTEM support Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  21. Cryostat parameters during operation The temperature of HTSC current leads is in a range of 40-50К at different operating modes with or without currents in the wiggler coils. Protection of the HTSC current leads against overheat and combustion is based on temperature sensors located in junctions of normal conducting current leads with HTSC current leads. Screen of control system shows the cryostat parameters: vacuum, LHe level, currents, magnetic field, pressure and temperature distribution in the cryostat during normal operation mode. Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  22. Cryostat parameters during operation Topendsof HTSC currentleadstemperaturebehaviorduringstabilitytest The 4K stages of cryocoolers are equipped with copper heat exchangers which are situated in gas helium inside liquid helium tank. These heat exchangers liquefy helium gas effectively reducing the magnet temperature and the pressure in the helium tank. The equilibrium temperature can be decreased down to 3.0-3.6 K and, accordingly, the pressure in a tank can decrease down to 0.3-0.5 bar. The insulating vacuum at steady state of the cryostat corresponds to 10-7–10-8Torr. Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  23. Hall probe measurement in own cryostat Magnetic measurements systems for SC magnets: • Hall probes measurement system in bath cryostat • Stretched wire measurement in own cryostat Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  24. The bath cryostat has a parameters: • Height – 4.5 m • Diameter – 700 mm. • On the top flange contains special scanning system for magnetic measurements. • Five LakeShore Hall probes array is used for measurements inside liquid helium at 4.2K. • The Hall probes are mounted on the rotatable disk with 90 degree rotating angle for relative calibration and for magnetic field mapping. 2 meters scanner Top flange of the cryostat Hall probe array on rotatable disk Bath cryostat for magnet test Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  25. RelativecalibrationofHallprobes at4.1 Tesla Longitudinalmagneticfielddistributionatfieldlevel 4.1 Tesla(overlapping of all 5 Hall probes turned 90 degrees using relative calibration data) Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  26. Each pole has tapsconnected to fast multichannel voltmeter which accumulate measured data in memory. Quenchsignal stops voltmeter and the signal data analysis gives a possibility to know the pole number in which this quench was occurred. Voltage behavior in time during quench in different poles. quench was happened in pole 13. Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  27. Field integrals measurements with stretched wire method Main purposes: • To make a table of currents (main and correctors) to provide field ramping up and down without orbit distortion • To minimize field ramping time • To estimate field multipole integrals at any field level Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  28. Motivation of the method - beam orbit in magnetic field B(s) - beam rigidity - bending of stretched wire with current in magnetic field B(s) - Rigidity of stretched wire with current First term of equation may be neglected for thin wire The equations for beam and for wire are identical for Beam orbit and curvedwire are described by formulas (L-magnet field length) if initial angle and coordinate are equal to 0 at –L/2: angle deviation of beam orbit or wire at s-position X-coordinate of beam orbit or wire at s-position Angle and coordinate at L/2 Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  29. Scheme of measurements and calculations Total angle deviation L=L1=L2 Orbit distortion at condition Parameters: L1=L2~2 m I~0.5-2 A WPM accuracy – 1-5 mkm Tension force - ~ 10 N 1-st Field integral accuracy - ~4*10-5 T*m 2-nd field integral accuracy- ~ 10-4 T*m2 Wire position monitor Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  30. Main and corrector currents behavior during field ramping up for zero field integrals The currents in the windings versus magnetic field for zero first field integral Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  31. Second field integral during field ramping up and down First field integral during field ramping up and down Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  32. End of cryostat with antechamber tube (photo) Antechamber tube Tube translator Tube tension system Cryostat flange Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  33. Site Acceptance Test with Hall probe measurement system Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  34. Hall probes measurements setup Stretched line For Hall probe measurements Step motor Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  35. Field distribution at zero currents(after normal operation) Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  36. Longitudinal field distribution at B=4.2 Tesla Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  37. Resumeand future plans • The technology of fabrication of horizontal racetrack coils for multipole magnetic systems with the period from 30 mm and above is debugged. About 20 superconducting multipole magnetic systems are successfully working in the various SR centers as SR generators. • Use of horizontal racetrack coils in multipole magnetic systems have shown the reliability and simplicity in manufacturing. Almost all defects of some coils caused by defect of a wire or errors at winding are finding at room temperature. If a defective pole is found during low temperatures tests in bath cryostat it is replaced easily. • Large number of splices also does not represent any problem due to very small contact resistance. • The magnetic system with horizontal racetrack coils has no any length limitation. • Bath cryostat with liquid helium and cryocoolers has proved as a reliable cryogenic system able during years to work independentlyin the conditions of limited access • Based on the experience of the fabricated short period wigglers it is possible to assert that the minimum period of magnetic system with horizontal racetrack coils can be limited by 12 mm. • The magnetic system with horizontal racetrack coils with indirect cooling was developed and created • Cryostat for magnet with indirect cooling was developed and created. • Superconducting undulatorwith horizontal racetrack coils ,with the period of 15-20 mm and with indirect cooling system is planned to be fabricated in the nearest future. Superconducting Undulator Workshop, RAL,UK April 28-29, 2014

  38. Thanks for attention Superconducting Undulator Workshop, RAL,UK April 28-29, 2014