An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Magnetometer Booms • Vibration Issues • Berkeley Composites Laboratory • Department of Mechanical Engineering • University of California at Berkeley

  2. Overview

  3. Deployment FGB stowed FGB deployed on gravity offset fixture SCB deployed on gravity offset fixture SCB stowed

  4. Deployment 1) Frangibolts Actuated 2) Elbow DAD Releases 3) Mid-deployment 4) Fully Deployed

  5. Vibration Testing (PER slide)

  6. SCB Base Bracket Use larger washers to better support feet. Repeat vibration. Round off corners. Repeat vibration. Fatigue crack in near foot still appear (not clearly shown) Fatigue crack in near foot Machine off existing feet and retrofit wider feet. Repeat vibration. Base bracket with retrofitted feet has no damage. Near foot has no damage; Yielding in far foot

  7. Base Hinge Fretting/ Galling Alodine aluminum clevis Steel washer between clevis and bronze spool (only lower washer visible in picture.) Bronze spool captures base spring. Non-load bearing (vertical direction) FGB and SCB share common hinge mechanism

  8. Base Hinge Fretting/ Galling Clevis inside surfaces Steel washer on clevis Steel washers Steel washer and bronze spring spool Bronze spring spool

  9. Frequency shift Frequency shifts without damage to instrument after random vibration. G10 thermal isolators Missing chamfer (machining error) causes binding of upper stop and clevis.

  10. F1 random vibration F1 booms re-designated F6 flight spare because of the accumulated random vibration time

  11. Random Vibration Specs • Random Vibration Levels (Ref. Swales SAI-TM-2430-Rev D )