1 / 11

DAQMB Status – Onward to Production! S. Durkin, J. Gu, B. Bylsma, J. Gilmore,T.Y. Ling

DAQMB Status – Onward to Production! S. Durkin, J. Gu, B. Bylsma, J. Gilmore,T.Y. Ling. DAQ Motherboard (DMB) Initiates FE digitization and readout Receives and sends FE data to DDU Provides Slow Control interface to FE boards (VME-JTAG). 515 boards in System.

howie
Télécharger la présentation

DAQMB Status – Onward to Production! S. Durkin, J. Gu, B. Bylsma, J. Gilmore,T.Y. Ling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DAQMB Status – Onward to Production! S. Durkin, J. Gu, B. Bylsma, J. Gilmore,T.Y. Ling • DAQ Motherboard (DMB) • Initiates FE digitization and readout • Receives and sends FE data to DDU • Provides Slow Control interface to • FE boards (VME-JTAG) 515 boards in System Pre-production Board has been Unchanged for ~2 Years Radiation Tests with 60 MeV Protons at UCD August 2002 Davis (2 days) September 2003 Davis (1 day)

  2. E>100 KeV 1012 1011 Neutron Fluence (cm-2) Neutron Flux (cm-2s-1) ME11 ME11 ME12 ME13 1010 10-6 1 10-3 103 Neutron Energy (MeV) Radius (cm) Radiation Levels at Peripheral Crates Calculations by M. Huhtinen Integrated over 10 LHC years (5x107 s at 1034 cm-2s-1) Neutron Fluence (>100 keV): (1 - 4) x 1010 cm-2 Total Ionizing Dose: (0.07 – 0.7) kRad

  3. Worst-case Radiation Environment • Measure SEE (SEU and SEL) cross sections for neutron fluence of 4x1010 cm-2 • Measure TID effects up to a dose of 2 kRad • Measure degradation for an equivalent neutron fluence of 2x1012 cm-2

  4. Radiation Test Summary 1 2 1 FIFO bit errors small and correctable using CRC word 2 Bipolar also irradiated at OSU reactor

  5. Cumulative effects • Total ionization dosage (with 63 MeV protons) • No deterioration of performance up to 5 krad • Displacement damage (with 2x1012 cm-2 n’s @ 1 MeV) • Usable voltage regulators and references identified • Single-Event Effects • No latch-up for all chips up to 4x1010 p cm-2 • Single Event Upset (SEU) • Cross sections measured for all FPGA’s, Links. • All SEU’s in FPGA’s recoverable by reloading SEU’s dominated by FE Electronics ~50:1 FE Electronics resets will also reset DAQMB

  6. 25 nsec Structure Test Beam (DAQMB Summary) Resets – no issues Timing – no issues Backplane communications – no issues DAQ Readout – no issues • DAQ rate tests carried out with high intensity pion beam. • 100 KHz L1A (scintillators), 100 KHz LCT, 1 Kz matched L1A-LCT with 16 SCA sample readout. No Problems. • When L1A-LCT matching increased to 10 KHz, event got overwritten, DMB buffer not empty. • Repeat above with 8 sample readout. No problems

  7. Magnetic Testing < 4 kGauss at Peripheral Crates Rare Earth Magnet Rated 12 kG Measured 4 kG (0.5 cm) No magnetic effects observed Burn In What do other people do ? CDF: 50-60 C for 8-24 Hrs Sufficient for tantalums failures No sensitivity to semiconductor failure US Military: 125 C for 320 Hrs Chip Makers recommend against this Each board 65C for 24 Hrs Test Before and After

  8. Production Test Software Written and Tested

  9. Preproduction Crate Test We have never tested a full crate of electronics - 11 DAQMB ordered (Sept 10, 2003) - Boards will be stuffed commercially Test ball grid arrays Do we have enough TMB’s … Jay? Conclusion ESR November 6, 2003 Then Production …

  10. Status Gigabit to VME Controller B. Bylsma, S. Durkin Virtex II Pro - much simpler VME controller - programming all on Linux PC - same drivers as alternate DAQ path - commercial gigabit ethernet card in PC - inexpensive ~$600/unit VME Buffers FIFO Gigabit Ethernet Transceiver Prom Voltage Regulators Not Needed for Raw Packets Packet length 64 bytes minimum, 9000 bytes maximum Data Format: crate cmd vme address vme data 8 8 32 16 Even without packing or buffering VME rates are reasonable! 2048 bit => 2 microseconds download , 2 Mbit FPGA in 2 seconds

  11. Distributing Gigabit Ethernet NETGEAR Gigabit Ethernet Switch Level 2 (MAC addresses) , 12 gigabit fiber ports $2000 Status • Parts Ordered/ Most in Hand • PC Board to Company next week • Gigabit ethernet included in Virtex II (no firmware) • - VME Master firmware being written Controller will be debugged within a Couple of Weeks

More Related