1 / 13

IHE Eye Care: Ophthalmic Devices and DICOM IODs

IHE Eye Care: Ophthalmic Devices and DICOM IODs. IHE North America Webinar Series 2008 Mike Schmidt Medflow Inc. Learning Objectives . How to categorize ophthalmic devices Mapping to/from DICOM modality codes What DICOM IOD’s to use Goal:

ikia
Télécharger la présentation

IHE Eye Care: Ophthalmic Devices and DICOM IODs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IHE Eye Care:Ophthalmic Devices and DICOM IODs IHE North America Webinar Series 2008 Mike Schmidt Medflow Inc.

  2. Learning Objectives • How to categorize ophthalmic devices • Mapping to/from DICOM modality codes • What DICOM IOD’s to use Goal: Help you understand what is needed to adapt software products to IHE Eye Care

  3. Ophthalmic Device Typesan informal list Lensometer Autorefractor / Keratometer Pachymeter Autophoropter Ultrasound B-Scan Ultrasound A-Scan Biometer Optical A-Scan Biometer Endothelial Camera Operating Microscope Digital Slit Lamp Digital Fundus Camera Visual Field Analyzer OCT Scheimpflug Camera Corneal Topographer Wavefront Analyzer GDx HRT

  4. Modality Codes – CID 29

  5. Acquisition Device Type CID 4202 Attribute (0022,0015) in OP parameters module

  6. Acquisition Device Type CID 4210 Attribute (0022,0015) in OPT parameters module

  7. IHE Eye Care SOP ClassesOphthalmic Images

  8. Stereometric Relationships The stereometric relationship module is used to identify pairs of images that may be viewed in stereo. It is possible that the same image or frame may be a member of multiple pairs. The images forming a pair shall be in different SOP Instances. The images forming a pair can be in different Series. All instances referenced in this Module shall be in the same Study as the Instance in which the Module occurs.

  9. IHE Eye Care SOP ClassesRadiological Images

  10. IHE Eye Care SOP ClassesEvidence Documents The PDF contents of the DICOM Encapsulate PDF objects shall conform to PDF/A-1a

  11. IHE Eye Care SOP ClassesRefractive Measurements

  12. Summaryputting it all together…

  13. Summaryputting it all together…

More Related