MiCOM S1 Studio software. Software Download. Download MiCOM S1 Studio software.

indiya
Télécharger la présentation

MiCOM S1 Studio software

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MiCOM S1 Studio software

  2. Software Download

  3. Download MiCOM S1 Studio software • ● This new release is fully compatible with your existing Schenider Electric V3.4.0 (patch 1 )installation and database as well as all MiCOM relays currently installed. No data sources will be deleted unless explicitly selected during uninstallation. • The installation will retain all your existing data models, and systems/projects (containing devices, configuration files and extracted records). • ●Internal link (Schneider users, open SWEBI before) • http://shoppingkiosk.schneider-electric.com/ • doc_info.aspx?FileID=197313&isdvd=False&df=12&gid=162251 • ● Customer access • http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2310-micom-user-software/61035-micom-s1-studio/?xtmc=MiCOM%2520S1%2520Studio&xtcr=1

  4. Software installation

  5. Starting installation Warning: disable antivirus software before installation Launch Installer

  6. DataModelManager • At the end of installation, close S1 studio & launch Data Model Manager : • If requested, select another language

  7. DataModelManager • 2 actions available : • Add/Suppress DataModels • Export/Import DataModels

  8. DataModelManager • « Add » or « Remove » Menu : • Select DataModel source for installation • AREVA FTP is recommended for old DataModels as well as up to date!

  9. DataModelManager • « Add » or « Remove » Menu : • Select requested used in DataModels

  10. DataModelManager • « Add » or « Remove » Menu : • Check protections used

  11. DataModelManager • « Add » or « Remove » Menu : • Protection description appears • For some relays, select only requested software version • Required Hard Disk space for installation is displayed

  12. DataModelManager • « Add » or « Remove » Menu : • To remove DataModels, use same process

  13. DataModelManager Check Datamodels files on your Harddisk : • to check that the files have been actually installed: • C:\ ProgramData\Schneider Electric\MiCOM S1 Studio\Datamodels • Nota: To access this directory you have to authorize in Window Explorer the access normally hidden to these files.

  14. Getting started with Studio

  15. Starting S1Studio • 3 windows available

  16. Starting S1Studio • Studio Explorer window, to display network or substation architecture, with associated protections

  17. Starting S1Studio • Properties window, to display informations about selected object (protections…) such as comment, date of last modification…

  18. Starting S1Studio • Main window, to display protections settings

  19. Starting S1Studio • To start, S1 Studio requires a « System »

  20. Starting S1Studio • System name is displayed in Studio Explorer • Properties are also visible

  21. Creating architecture

  22. Creating architecture • At each step, you can add : • A new electric level • A new protection device

  23. Creating architecture • Electric levels available are : • Substation • Voltage Level • Bay • At each level, you can add a protection device

  24. Creating architecture • .ldb file is visible only when the system is open • .ms1s is the System • The folder contains the whole system architecture with relay settings, events & disturbance files • Whole architecture can be retrieved under Windows environment

  25. Add a protection device

  26. Add manually a protection device 2 • To add a device : • select the location where to put the device • click on New Device • follow instructions 1 3 • Requested device : P343111A2M0320J

  27. Add manually a protection device • follow instructions 3 • Requested device : P343111A2M0320J

  28. Add manually a protection device • follow instructions 3 • Requested device : P343111A2M0320J

  29. Add manually a protection device • Check protection code and choose language for setting file 4 • Requested device : P343111A2M0320J

  30. Add manually a protection device • Fill in protection name and comment if required 5

  31. Add manually a protection device • Structure of all relays is similar : • 20 serie • 30 serie • 40 serie • Green : connexions • Yellow : settings • Blue : records

  32. Add automatically a protection device 2 • It is also possible to add a device quickly and automatically 1 • Select required location for the relay to be added • Click on « Quick Connect »

  33. Add automatically a protection device • Select device type • Select communication port you are using 4 3

  34. Add automatically a protection device • S1Studio automatically identify relay CORTEC code and add it in Studio architecture. 5

  35. Add automatically a protection device • When opening an existing system or after a quick connection, some devices may be displayed in white : it means that Data Model is not installed. • Use Data Model manager to install required Data Models then you are able to display settings… (quit MiCOM S1 Studio before starting data model manager) • When DataModel is found, device is displayed in gray colour.

  36. Setup connection

  37. Setup connection • Communication settings memory • Right click on Connection to create a new connection • This step allows the system to identify once the device and to keep in memory communication parameters. • For the first time set the default parameters of the relay that you would be able to read on the LCD. • It will not be anymore required to open/close connexion to the device, it is automatic! • Default password : AAAA • Note : a connexion already exists if the relay has been added automatically with quick connect

  38. Settings file

  39. Settings file • « Settings » • Create a new settings file • Add an existing file • Extract settings from device (it creates a new file) – connection* is required • Extract full settings from device even read only parameters and meny labels (Px4x only) – connection* is required • * Connection • Right click :

  40. Settings file • Programmable Scheme Logic – (Px4x only) • Text menu modification – (Px4x only) • It is possible to extract PSL from relay – connection is required • Right click :

  41. Settings file • When selected a file, its properties as displayed, such as : • CORTEC code • Creation and last modification date • Windows path • Comment

  42. Settings file • To send setting files to the relay : 2 • Select the relay • Click on « Send » 1

  43. Settings file • To send setting files to the relay : • Select settings & PSL files (if required) to be sent 3 • Certains relais peuvent intégrer les commentaires avec la logique

  44. Settings file • How to display a settings file 2 • Select file • Click on « Open » Rename the file 1 Cut/Copy the file Display Options Display file properties Remove the file

  45. Settings file • Open a 20 Serie relay setting file :

  46. Settings file • Open a 30 Serie relay setting file :

  47. Settings file • Open a 30 Serie relay setting file :

  48. Settings file • Open a 40 Serie relay setting file :

  49. Settings file • Open a 40 Serie relay PSL file : • Use of PSL requires an external program, PSL Editor, automatically launched (included in Studio package!)

  50. Settings file • How to use Settings Editor • 2 types of parameters : • Read/Write parameters • Read only parameters • To be extracted from the relay • New in Studio : • Parameter internal Address is displayed • Comments can be added