11 th Annual OSU and Smoke Round Robin. Presented By Mike O’Bryant (The Boeing Co) 7/11/2006 at C&D Zodiac. Some of the data we ask for:. Where and when was the heat flux gauge calibrated? What is W/cm^2 range of the gauge? What is the OSU brand? What is the Gauge brand?.

irina
Télécharger la présentation

11 th Annual OSU and Smoke Round Robin

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 11th Annual OSU and Smoke Round Robin Presented ByMike O’Bryant(The Boeing Co)7/11/2006 at C&D Zodiac

  2. Some of the data we ask for: • Where and when was the heat flux gauge calibrated? • What is W/cm^2 range of the gauge? • What is the OSU brand? • What is the Gauge brand?

  3. Vatell calibration estimated to be 9% cooler based on peak time

  4. Statistically significant factors based on 3 years of data.

  5. Recommendations • Develop a new panel optimized to have a good peak time to heat flux correlation • Use an IR imager to characterize heat loss of OSUs • Visit other labs, especially the outliers to gain understanding. Bring the IR imager • Develop a finite element analysis model of the OSU to better understand significant variables

  6. Recommendations (cont.) • Extend calibration equilibration time from 2 minutes to 3 minutes per step. Use average of 1L/Min steps before and after each increase

  7. Recommendations (cont.) • Extend calibration equilibration time from 2 minutes to 3 minutes per step. Use average of 1L/Min steps before and after each increase

  8. Recommendations (cont.) • Extend calibration equilibration time from 2 minutes to 3 minutes per step. Use average of 1L/Min steps before and after each increase • Re-establish OSU QA task group. Especially need members willing to participate in mini round robins within the group, collect data on more operational parameters, and be willing to participate in exchange visits.