Intrarile de zone. pentru senzori. Exemplu: PIR. + aux -. COM. Z. 5,6 k Ω 5%. Tipuri de conexiuni. - Conexiunea EOL. C NC +12V -. - Conexiunea D-EOL. - Conexiunea in bucla. Conexiunea EOL. NC. NO. NC + NO. 2NC + 2NO. COM. COM. COM. Z. Z. Z.

italia
Télécharger la présentation

Intrarile de zone

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Intrarile de zone pentru senzori Exemplu: PIR + aux - COM Z 5,6 kΩ5% Tipuri de conexiuni - Conexiunea EOL C NC +12V - - Conexiunea D-EOL - Conexiunea in bucla

  2. Conexiunea EOL NC NO NC + NO 2NC + 2NO COM COM COM Z Z Z COM Z C NC C NC C NC C NC 5,6 kΩ5% C NC C NC C NC 5,6 kΩ5% 5,6 kΩ5% C NC EOL - R = End Of Line Rezistor (rezistenta capat de linie) 5,6 kΩ5%

  3. Conexiunea D-EOL DEOL - R Avantaj: COM Z Permite detectarea unui senzor: • in alarma • R= 11,2 kΩ • cu capacul deschis • R= ∞ • cu intrarea de zona scurtcircuitata • R= 0 Ω C NC T1 T2 5,6 kΩ5% D-EOL R = Double End Of Line Rezistor 5,6 kΩ5% (doua rezistente capat de linie)

  4. Conexiunea in bucla Programare in sectiunea [13], opt[1] ON pentru bucla inchisa fara rezistor. COM Z + aux - 5,6 kΩ5% C NC C NC C NC C NC +12V - +12V - +12V - +12V -

  5. PC5108 – modul de extensie 8 zone cablate OFF ON ON - + KEYBUS Magistrala de comunicatie Conexiune senzori Iesire aux de tensiune U=12V, Imax=100mA

  6. PC5108 – modul de extensie 8 zone cablate

  7. Programare PC5108 Power (PC5010, 5020) NewPower (PC1616/1832/1864). [*][8] [cod instalare (5555)] [902] Module Supervision Reset Pauza 1 min [903] Module Supervision Field [#] [001] - [004] Zone definition [001] z1-z16 [002] z17-z32 [003] z32-z48 [004] z49-z64 [203] - [209] Zone assignment – Partitia1 - - - - - - [#] [211] - [219] Zone assignment – Partitia2 ! Atentie: Doar Partitia1 este activa la ‘setarea din frabrica’ Daca se doreste utilizarea celorlalte partitii (ex: Partitia2) trebuie activate din sectiunea [201]

  8. Programare RF5108-RF5132 Wireless Module Power (PC5010, 5020) NewPower (PC1616/1832/1864). [*][8] [cod instalare (5555)] [804] Wireless Expansion Programming [01]—[32] sectiuni de introducere ESN pt zone (inrolare) [41]—[56] sectiuni de introducere ESN pt telecomenzi (inrolare) [902] Module Supervision Reset Pauza 1 min [903] Module Supervision Field - pentru verificare [#] [001] - [004] Zone definition [001] z1-z16 [002] z17-z32 [003] z32-z48 [004] z49-z64 [101] - [164] Zone attributes [8] ON- definire ca zona wireless [211] - [219] Zone assignment – Partitia2 [203] - [209] Zone assignment – Partitia1 - - - - - - [#] Observatii: 1. Senzorii wireless WS4904 intra in stare de inactivitate timp de 6 min daca detecteaza trafic intens. Pentru resetare se efectueaza un tamper (se scoate din suport si se introduce inapoi). 2. Senzori functioneaza normal doar daca sunt fara stare de tamper (sun introdusi in suport) 3. La centrala doar Partitia1 este activa la ‘setarea din frabrica’. Daca se doreste utilizarea celorlalte partitii (ex: Partitia2) trebuie activate din sectiunea [201], iar zonele asignate in [211]

  9. Cablare