Transmitted Birefringent Sensor for Optical Displacement Measurement. Ching-Shing Wang, Jhao-Heng Wang, and Ruey-Ching Twu* Department of Electro-Optical Engineering, Southern Taiwan University of Science and Technology Tainan, Taiwan *E-mail: rctwu@mail.stust.edu.tw. STUST. Abstract.

jariah
Télécharger la présentation

STUST

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transmitted Birefringent Sensor for Optical Displacement Measurement Ching-Shing Wang, Jhao-Heng Wang, and Ruey-Ching Twu* Department of Electro-Optical Engineering, Southern Taiwan University of Science and Technology Tainan, Taiwan *E-mail: rctwu@mail.stust.edu.tw STUST Abstract A novel transmitted-type birefringent sensor is proposed to measure displacement in a heterodyne interferometer. The sensitivity of phase versus displacement can be improved by using an immersed KTP plate in a glycerin solution. Introduction The birefringent materials can make a phase delay between two orthogonal polarizations of a propagating light which are widely used for waveplates and electro-optic modulators [1,2]. Usually, the phase delay is dependent on a birefringence and thickness of a birefringent plate (BP), and an incident angle of the incident light [1]. Moreover, the relative refractive index between the birefringent plate and the environment also will change the phase delay values. When the incident light has a lateral displacement onto a spherical lens, the displacement will make a refractive angle change. The lens is a useful transducer to transfer the displacement to the angle changes. In the past decades, a prism-type surface plasmon resonance (SPR) sensor has been widely used in an angular displacement measurement [3]. By combing the lens and the SPR devices, the optical displacement measurement apparatus has been demonstrated successfully [4,5]. Although the SPR-based displacement measurements can achieve a high resolution, a limited distance range and a specific incident angle are the main drawbacks. In this paper, a novel optical displacement transducer has been evaluated by using a glass cylinder embedded with the BP immersed in a glycerin solution. The proposed BP transducer has a compact size in comparison with the SPR-based one. By the way, this transducer has more flexible for setting the initial incident angle. The dynamic range of measurement is better than the SPR-based one. Experimental Setup (b) (a) Fig. 1 (a) Schematic diagram of an optical displacement measurement apparatus and (b) transducer. Experimental Setup 40μm 40μm Fig. 2 Phase variation as a function of refracted angle in the displacement sensor. Fig. 3 Phase variation as a function of sinusoidal displacement shifts: (a) LN plate and (b) KTP plate. Conclusion In conclusion, a simple and novel transmitted-type birefringent sensor was successfully demonstrated to measure a small displacement in a heterodyne interferometer. The displacement measurement sensitivity can be improved by using an immersed KTP plate in a glycerin solution. The compact transducers have advantages of less precise angle requirements of the incident light and wider displacement range than conventional SPR-based transducer. Reference [1] C. H. Hsieh, C. C. Tsai, H. C. Wei, L. P. Yu, J. S. Wu, and C. Chou, Appl Opt, 46 (2007) 5944-5950. [2] K. H. Chen, W. Y. Chang, and J. H. Chen, Opt Express, 17 (2009) 14143-14149. [3] H. P. Chiang, J. L. Lin, R. Chang, and S. Y. Su, Opt Lett, 30 (2005) 2727-2729. [4] J. Y. Lin, K. H. Chen, and J. H. Chen, Opt Laser Eng, 49 (2011) 811-815. [5] S. F. Wang, Sensors, 9 (2009) 2498-2510. [6]R. C. Twu, Y. H. Lee, and H. Y. Hou, Sensors 10 (2010) 9609-9619.

More Related