An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New results from CLAS12 forward resistive Micromegas produced by CIREA/ELVIA and CERN Gabriel CHARLES

  2. New results from CLAS12 forward resistive Micromegas built by ELVIA and CERN Collaboration with ELVIA Geometry of the detector and first measurements Tests with a cosmicbench Conclusions G. Charles Workshop RD51, 24/04/2013 0

  3. Micromegas production at CIREA Conclusion slide by D. Neyret for the previous RD51 mini-week G. Charles Workshop RD51, 24/04/2013 1

  4. ForwardMicromegas for CLAS12 Gerber view • Specifications : • active area : 430 mm diameterdiskwith a 50 mm diameterholeat the center • PCB thicknesslessthan 100 µm and glued on ROHACELL • 500 µm pitch, with 100 µm betweentwostrips • resistivestripsà la Joerg Central zone Two prototypes tested Prototype by CERN Prototype by CIREA G. Charles Workshop RD51, 24/04/2013 2

  5. Stripresistivity for the CERN prototype The resistivitywasmeasuredin more than 400 points on a non-bulked PCB Strip 0 strip Strip 290 Ground Strip 960 Courtesy: D. Attié G. Charles Workshop RD51, 24/04/2013 3

  6. Cosmic test bench • The twoforward prototypes have been tested • For both, more than 500,000 triggers have been recorded • For each trigger, when a cluster isreconstructed in all the reference detectors, the trackisinterpolated to the prototype • The position interpolatedisthencompared to the cluster reconstructed in the detector under test G. Charles Workshop RD51, 24/04/2013 4

  7. First tests • No leakagecurrentafter one day • Excellent S/N ratio • Other variables consistent with standard Micromegas <S/N> ~ 140 atVmesh = 450 V <S/N> ~ 150 atVmesh = 460 V G. Charles Workshop RD51, 24/04/2013 5

  8. Efficiencies Prototype by ELVIA • Central zone not connected (forgethole in the drift) • Lowerefficiency on the top left part of the detector Prototype by CERN • Excellent efficiency on almost all the detector • Lowefficiency on the top left part of the detector G. Charles Workshop RD51, 24/04/2013 6

  9. Efficiencies Prototype by ELVIA • Central zone not connected (forgethole in the drift) • Lowerefficiency on the top left part of the detector • Efficiencyaround 90% Prototype by CERN • Excellent efficiency on almost all the detector • Lowefficiency on the top left part of the detector • Efficiencybetterthan 90% almosteverywhere G. Charles Workshop RD51, 24/04/2013 6b

  10. Gain ELVIA CERN Samefields for both detectors Amplification gaps are different. ! • The two detectors have lower gain bothat the same position • Just a coincidence ? A gasleak ? Switch gas entrance and exit to check • About gas circulation : the design willbesoonfinalized, simulations by finiteelements are ongoing G. Charles Workshop RD51, 24/04/2013 7

  11. Tests under X-ray generator Courtesy: C. Lahonde-Hamdoun and S. Procureur Preliminary conclusion : thereis no saturation at 1 MHz per cm². G. Charles Workshop RD51, 24/04/2013 8

  12. Conclusions and perspectives • Large size resistive MM by CIREA • Production withoutproblem • Prototype tested in cosmicbench and under X rays • Normal behaviorundercosmic rays : no leakagecurrent • First results on performances • Very good efficiency • No sign of saturation yetwith X-rays • Next CLAS12 resistivemay have lowerresistivity • Nextstepswith ELVIA • Test of forward prototypes of resistive MM made by serigraphy by ELVIA • Test of small (6x10 cm² active area) prototypes withburiedresistors for COMPASS • Large size (40x40 cm²) non-simplified prototype for COMPASS 500 µm G. Charles Workshop RD51, 24/04/2013 9