1 / 22

Acute Pulmonary Edema/CHF  1. Initiate O2 via Mask or Cannula according to distress

Acute Pulmonary Edema/CHF  1. Initiate O2 via Mask or Cannula according to distress 2. ALS Crews initiate CPAP 15-25 L/min (5-10 cm H2O) according to distress. 3. Initiate IV with saline lock or NS at KVO rate. 4. Monitor EKG and Vital signs.

jeffery
Télécharger la présentation

Acute Pulmonary Edema/CHF  1. Initiate O2 via Mask or Cannula according to distress

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Acute Pulmonary Edema/CHF •  1. Initiate O2 via Mask or Cannula according to distress • 2. ALS Crews initiate CPAP 15-25 L/min (5-10 cm H2O) according to distress. • 3. Initiate IV with saline lock or NS at KVO rate. • 4. Monitor EKG and Vital signs. • 5. Administer Lasix 40-100 mg IV • 6. If B/P >100 systolic administer NTG 0.4 mg SL up to 3 doses • 7. Consider Albuterol up to 5 mg Neb. if bronchospasm/ wheezing is present. • 8. Contact Medical Control for Morphine 2-10 mg IV • Pediatric Doses • Lasix 1.0 mg/ kg IV • Albuterol up to 5 mg via nebulizer • NTG is not used. • _______________________ _________________ • Peter Hyman, MD Date

  2. Acute Respiratory Distress (COPD, Asthma) 1. Initiate O2 via Mask or Cannula according to distress 2. ALS Crews initiate CPAP 15-25 L/min (5-10 cm H2O) according to distress. 3. Administer Albuterol up to 5.0 mg via nebulizer at 8-10 L/ minute. 4. Monitor EKG and Vital signs. 5. Initiate IV with saline lock or NS at KVO rate. 6. Contact Medical Control Pediatric Doses (ages 2-12) Albuterol up to 5.0 mg via Nebulizer at 8-10 l/min.

  3. Boussignac CPAP System • Select the appropriate size face mask for your patient: - Child Mask (Size 3) - Small Adult Mask (Size 4) - Medium Adult Mask (Size 5) - Large Adult Mask (Size 6)

  4. Boussignac CPAP System • Set Oxygen flow to deliver CPAP in cmH2O of water pressure: - 15 liters = 5cmH2O - 20 liters = 7.5 cmH2O - 25 liters = 10 cmH2O

  5. Boussignac CPAP System • Connect funnel end of Green Oxygen Tubing to an O2 source capable of delivering flow up to 25 liters/min. • This provides the full range of CPAP needed for clinical use (5-10cmH2O). • Typically a “D” size cylinder in the field.

  6. Boussignac CPAP System • Insert white end of the Boussignac CPAP into the face mask.

  7. Boussignac CPAP System • If required, insert a pressure manometer between the Boussignac CPAP and the face mask.

  8. Boussignac CPAP System • Explain to the patient how the Boussignac CPAP will help their breathing. • Gently hold the mask to the patients face insuring a good face/mask seal. • Turn the flow control device to the desired liters/min, generally 15 l/min, to begin the CPAP. • Gradually adjust the flow to achieve the desired level of CPAP.

  9. Boussignac CPAP System • Secure the Boussignac CPAP System to the patient with the head strap. • Check around the mask for any leaks. • Adjust the mask and/or head strap accordingly.

  10. Boussignac CPAP System • If the patient requires suctioning of the oral cavity, insert French size suction catheter through the open end of the Boussignac CPAP System. • CPAP pressure will not be affected.

  11. Boussignac CPAP System • CO2 can be monitored with either a nasal cannula or an in-line CO2 adapter.

  12. Boussignac CPAP System • When transporting the patient in the ambulance, connect the Green Oxygen delivery tube to the wall Oxygen in the vehicle.

  13. Boussignac CPAP System + Nebulizer • Fill the nebulizer with the prescribed medication.

  14. Boussignac CPAP System + Nebulizer • Insert the 22 mm male end of the nebulizer into the face mask. • Insert the 22 male end (white) of Boussignac CPAP into the nebulizer.

  15. Boussignac CPAP System + Nebulizer • Connect the funnel end of the nebulizer’s gas delivery tube to a gas source. • Turn on gas source to 6 liters/min. to power the nebulizer. • Maintain O2 flow to Boussignac CPAP System at 15 l/min. (5cmH2O).

  16. Click here to go to Airway Management Slides

More Related