1 / 13

Grid-Tied System Sizing

Grid-Tied System Sizing. Module 11 Fall 2009. Sizing a Grid-Tied PV System. Design Beginning Points Annual Electric Usage Available Space For System Panels and Electrical Budget Constraints. Sizing Process:. Sizing begins at the load side and proceeds backwards to the array

job
Télécharger la présentation

Grid-Tied System Sizing

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Grid-Tied System Sizing Module 11 Fall 2009

  2. Sizing a Grid-Tied PV System • Design Beginning Points • Annual Electric Usage • Available Space For System Panels and Electrical • Budget Constraints

  3. Sizing Process: • Sizing begins at the load side and proceeds backwards to the array • Grid-Tied systems are usually sized as large as possible within limits of budget and space • Sizing of Stand-Alone systems involves a fine balance between energy supply and demand. Not covered in this class.

  4. Accepted Method for Certification in CoSEIA • Electric Load Estimation • 1. Approximate monthly and daily average energy use • Yearly Average energy consumption: 7000 kWh/yr • Avg. kWh/yr ÷12mo = 583 kWh/mo • Avg. kWh/mo ÷ 30 days = 19.5 kWh/day • This is Average Daily Load

  5. Accepted Method for Certification in CoSEIA • Electric Load Estimation • 1. Approximate monthly and daily average energy use • Yearly Average energy consumption: 7000 kWh/yr • Avg. kWh/yr ÷12mo = 583 kWh/mo • Avg. kWh/mo ÷ 30 days = 19.5 kWh/day • This is Average Daily Load

  6. Step 1a • 50% of power to be generated by PV • 19.5 (AC)kWh/day x 50% of power from PV = 9.75 (AC)PV system kWh/day

  7. 2. Array Sizing • Average Sun Hours per day…. Denver (5.5 – 6 hours) • See Irradiation chart • Or data in back of book

  8. Solar Radiation Chart

  9. 3. Determine PV system kW needed 9.75 (AC) PV system kWh/day ÷ 5.5 (ASH/day) = 1.77 (AC) PV System Kilowatts

  10. 4. Factor in inverter efficiency • 1.77 (AC) PV System Kilowatts ÷ .80 derate factor = 2.21(DC) PV array System kW needed • 2.2 kW PV array x 1000 Watts/kilowatt = 2200 PV array watts

  11. From the Book… • Establish design kWh/day • Divide by average peak sun hours • Factor in Inverter efficiency • Choose Modules • Inverter Sizing

  12. Inverter Sizing • Calculate total watts of array • Choose inverters that will pass that quantity of watts • Check string sizing software to evaluate overall compliance with design criteria • Decide how many strings your system will utilize

  13. End of Day 2 presentation