1 / 16

Column Radiator Series Installation & Technical Guide - Just Rads

MYSON COLUMN radiator's aesthetically sophisticated design was conceived for technologically superior heating. Their design form makes them suitable for a wide range of architectural applications from retro to modern.<br>Here is the Installation and Technical Guide of Myson Column Radiators<br>Order your Today: https://justrads.com/collections/myson-radiators

justrads
Télécharger la présentation

Column Radiator Series Installation & Technical Guide - Just Rads

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Column Radiator Series Installation & Technical Guide MYSON MYSON MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk heatingthroughinnovation. heatingthroughinnovation. 01.11.2011

  2. Contents/Warranty 02 COLUMN. MYSON COLUMNradiator's aesthetically sophisticated design was conceived for technologically superior heating. Their design form makes them suitable for a wide range of architectural applications from retro to modern. Contents Important information Product description Model overview / connection dimensions Piping & rough-in Wall bracket position information Optional Floor bracket information Heating outputs / weights / water content Piping arrangements Valve selection Heat output factors / System start - up 03 04 05 06 07 08 9 - 10 11 12 13 Myson, Inc. Limited Warranty Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first. Kontec The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value. NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity. Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims MUST be made within 10 days of receipt from Myson. No Exceptions. STEEL PANEL RADIATORS-- SELECT, T6, DÉCOR, COLUMN AND BENCH The duration of warranty for steel panel radiators is 5 Years. What is covered: • • Painted finishes will not peel or flake from the surface of the radiator The body of the radiator and its welded joints will not leak when the product is properly installed and maintained according to Myson's instructions. What is not covered: • Rust occurring from improperly sealed threaded connections oroxygen corrosion Basics • Electrolytic corrosion caused by failure to flush the system properly after initial installation

  3. Important Information 03 BEFORE YOU BEGIN BEFORE YOU BEGIN INTRODUCTION The Myson Column Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the Column Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness and dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service. CAUTION Step 1Read this entire instruction manual thoroughly before beginning installation. Step 2To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all the instructions carefully . Step 3Failure to follow these instructions will invalidate the manufacturer’s warranty. APPLICATION Myson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom- mended for gravity systems. DO NOT USE STEAM IN THESE RADIATORS. INSPECT FOR DAMAGE NOTE: Inspect materials for concealed shipping damage. You only have 10 days to file a freight claim. If items are damaged or missing, please call Myson at 1-800-698-9690. INSPECTION FOR COMPLETENESS Unpack the radiator carefully to avoid damage or loss of parts. The ColumnRadiator will come with the following parts: • Wall mounting bracket kit • Plastic inserts for noise suppression • Stainless steel solid plug • Vent plug IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION. Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/ herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used. DESIGN AND LAYOUT CONDITIONS Myson Column Radiators should only be used with a properly sized recirculation pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from yourcirculator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Column radiator is below a window where it can minimize downdrafts from glazed areas. SAFETY PRECAUTIONS Radiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of a radiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and users should ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installers and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be given to installing low surface temperature radiators, or to placing guards in front of the radiators. For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taken into consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the radiator, prior to finalising installation.IN ALL CASES IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION. Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  4. COLUMN product description 04 Radiators Radiators Manufacture Tube Details Paint Finish MYSON MYSON manufactured using a unique laser welding process that virtually eliminates the visible welding points associated with the traditional manufacturing this type of radiator. The clean finish significantly enhances the aesthetic qualities of the radiator. COLUMN COLUMN radiators are Precision, D-profile steel tube is used for all outside surfaces which ensures high outputs and edges for maximum safety. All MYSON COLUMN MYSON COLUMN manufactured and tested to EN 442. Every undergoes a multi-stage pre-treatment process followed by an epoxy polyester primer coating. A polyester powder coat in white (RAL 9016) is applied to all front and rear surfaces allowing COLUMN COLUMN to be fitted without further painting. MYSON MYSON COLUMN COLUMN radiator soft, rounded stoved epoxy methods of radiators are the MYSON MYSON MYSON COLUMN MYSON COLUMN radiators carry a 5 5 year guarantee against defects caused by faulty materials or manufacture. PR O DU C T D E SC R I P T IO N PR O DU C T D E SC R I P T IO N 12 - 3045 Overall Height [cm] Number of Columns Number of Sections ABOVE EXAMPLE: ABOVE EXAMPLE: 12 Sections,3 Column, 18"High 2 - COLUMN: 2 - COLUMN: Standard Heights: 18, 24, & 79 inches (45, 60, & 200 cm) Connections: 4 x internal thread G 1/2“ BSP welded-in for supply and return. Vent and drain plugs (or dummy plug) are included 3 - COLUMN: 3 - COLUMN: Standard Heights: 12, 18, & 24 inches (30, 45, & 60 cm) BSP, 4 - COLUMN: 4 - COLUMN: Standard Height: 24 inches (60 cm)  See pages 9 & 10 for standard number of sections and outputs Tested to positive pressure:  Additional sizes and models are available as special order 188.5 psi Maximum positive operating pressure: Coatings: 1. Undercoat: electrophoretic, using water-soluble paints, conforming to DIN 55900 part 1, stoved at 329 2. Finish: electrostatic powder coating, conforming to DIN 55900 part 2, in a state-of-the-art facility. (On request, and at a supplementary charge, a range of RAL and sanitary ware colours can be offered.) This particularly robust coating is stoved at an object temperature of 356 72psi max. 145 psi 329° F F; Maximum operating temperature: max. 248° F 356° F F. Packaging: 1. Cardboard packaging 2. Edge protection 3. Shrink foil Quality certificates 10 10 Strong brands of the highest quality 10 10 The standards that the quality certifi - cates require us to maintain give you security, the best heating performance and premium product quality. For the MYSON MYSON warranty conditions, please refer to the table of contents page of this manual. MYSON MYSON offers its customers strong brands that meet highest quality standards. All the production sites’ production processes are certified ac- cording to ISO. The quality and perfor- mance specifications of the convectors and heating panels have been verifi ed by recognised European institutions. 10 Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  5. COLUMN model overview / connection dimensions 05 Dimension and Mounting Quick Reference 2" 1 1/4" 1" 1 1/4" 21/2" 4" 51/2" 2 Column 4 Column 3 Column Length equals the number of sections times 2" Example: Example: 56 sections times 2" equals 112" All tappings are 1/2" BSPT All tappings are 1/2" BSPT 1-3/16" 2" 5/8" 3/4" 2-5/16" 3-1/4" DAV12 LKD16AN Position 1 Position 2 1/2" 4" Column Radiator Wall Brackets 1 3/4" Pipe centers from finished wall are dependent on which mounting slot is selected on the mounting bracket and the number of columns. CL Shown with DAV12 and LKD16AN valves. See page 12 for additional valve choices . 1 3/4" CL MYSON COLUMN RADIATOR ROUGH -IN SPECIFICATIONS ROUGH -IN SPECIFICATIONS MYSON COLUMN RADIATOR 2 Column 3 Column 4 Column 2 Column 3 Column 4 Column 3 31 1/ /4 4" 3 35 5/ /8 8" " 4" 4" 4 43 3/ /8 8" " Position 1 Min: 2 21 1/ /2 2" " Position 2 Max: 2 27 7/ /8 8" " " To obtain pipe centers using Myson valves multuply the number of sections by 2" and add 3.5". Example: Example: A 12 section radiator would be 12 x 2"+ 3.5" = 27.5" Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  6. 06 COLUMNpiping & rough-in Standard models Suitable for mono-flo, home run or 2-pipe systems All MYSON COLUMN All MYSON COLUMN radiators are ordered withoutan internal baffle. This will not effect the output of the radiator except in cases where the radiator is less than 4 sections long or is a 2 column radiator less than 8 sections long. These smaller radiators should be ordered with a baffle in the supply position. Contact MYSON Tech Support for more information. more information. All systems must be designed with suitable pipe sizing and with adequate pump head. Failure to do this may lead to trapped air and cold spots because of insufficient pressure and water flow will not drive the air from the radiator. The taller and more tubes a radiator has, the more likely this is to happen. The installation work must be carried out with precautions taken to avoid contamination which could lead to corrosion. If a corrosion inhibitor or other water treatment Manufacturer’s Instructions must be strictly followed. is to be used, the Contact MYSON Tech Support for The MYSON COLUMN radiator's large diameter steel tube contruction pressure drop through the radiator. The pressure drop through the radiator can be ignored in the design of most hydronic systems. ensures a negligible MYSON COLUMN MYSON COLUMN radiators are suitable for the use of BBOE BBOE (Bottom Bottom Opposite End), TBSE Bottom Same End) and TBOE TBOE (Top Bottom Opposite End) connections. TTOE (Top Top Opposite End) connections cannot be used. connections cannot be used. TBSE (Top Top Top Opposite End) Basic upgrade Basic upgrade: use 1 - FF16WAC manual valves, angle only, chrome plated with white handles (FF16WAC is adjustable for balancing, FF16LAC is fixed open but can be closed for service) FF16WAC and 1 - FF16LAC FF16LAC • All installations require 2 valves per radiator • • All valves are ½” BSP thread radiator radiator and ½” NPT thread system system (also includes compression nut and ferrule includes compression nut and ferrule for connection to ½” copper) ½” BSP thread for connection to the ½” NPT thread for connection to the to the to the • TRV TRV (thermostatic radiator valves) are available for automatic temperature control of individual radiators: available in 3 body patterns, with or without thermostatic head (sensor), use in conjunction with LKD or FF LKD or FF • Valves are available in 3 basic patterns: angle, straight, and inverted angle (TRV only) use in conjunction with • Basic Installation Basic Installation: use 2 – LKD16AN LKD16SN LKD16SN (straight) manual valves, nickel plated with screwdriver stops and caps LKD16AN (angle) or See page 12 for additional valve information NOTE: NOTE: See page 5or 7 for rough-in from finished wall to pipe centers. LKD16AN LKD16AN FF16WAC FF16WAC TRV TRV NOTE ! Rough-in Myson will not be responsible for damage or repair of property resulting from the use of non-Myson valves. Rough-in information is given for Myson control valves. Valve specifications vary by manufacturer. Rough-in Rough-indimension shown at right is for a TRV LKD LKD valve or a pair pair of LKD LKD valves. When using FF FF valves add 3-5/8" Recommendation: Recommendation: Radiator tappings and valve spuds are 1/2"BSP Professional expertise is required when sealing these "straight" "straight" threads. Failure to properly seal the connections will result in leaks resulting in property damage. TRV and a 3-5/8" to overall length. 1/2"BSP. Overall Length + 3-1/2" Overall Length + 3-1/2" NOTE ! NOTE ! Myson is not responsible for damage resulting from improper workmanship. Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  7. COLUMN Technical Information 09 COLUMN Mounting Bracket Detail 07 Fixing Brackets - Clamped Floor Bracket FK Mounting Brackets (supplied with every radiator) - Wall Brackets 8 2" 13/16" Complete system for free-standing radiators, from 2-6 column up to 1000mm height. RAL 9016. 26 20 3/4" 5/8" Painted to 10 120 30 Comprises; 180-300mm 4026 - 3mm thick base-plate fixing for either finished or unfinished floor 13/32" 3/16" 1/4" 1/4" 9/16" 60 100 25/16" 11/32" 11/16" Clamped Floor Bracket FK Order Code 15/64" 31/4" Dimensions of base-plate for Clamped Floor Bracket FK ( = base-plate cover) For 2-6 Column Rads. Base-Plate Cover FK1021 COVERFK 13/16" 9/16" 3/16" 3/8" For use with 2-6 column radiators 19/32" 9/64" 1/2" 11/16" Two-part cover for base-plate in white plastic 106 x 128mm 25/32" Floor Bracket SK Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016. Radiator Brackets Comprises; - 3mm thick base-plate for fixing to either finished or unfinished floor A (see table below) Two-part cover for base-plate in white plastic 110 x 135mm - upright support 35 x 10 x 1.5mm, fixing set with adjustable bracket, security fixing, anti-vibration insert Ensure tight fit here 3/4" 19/32" - adjustable bottom support with spacer and anti-vibration insert, white plastic end stop for top of upright. 91 security fixing, 27/16" 7/16" 8 104 75 Height of Upright Height of Radiator 1/2" Order Code Radiator Bracket 116 460 610 760 910 300 450 600 750 SK20046 SK20061 SK20076 SK20091 COVERSK Dimensions of base-plate for Floor Bracket SK 1" Angle Wall Bracket 15/32" 7/16" 25/32" Base-Plate Cover 13/16" Wall & Bracket Wall Bracket & Radiator Bracket Wall & Radiator A = Distance between Wall & Center 2 column 3 column 4 column Operating Pressures Every MYSON COLUMN radiator is tested to a pressure of 13 bar (188.5 psi) and is suitable for a working pressure of up to 10 bar (145 psi). 25 1 13 3/ /16 32" "2 21 1/ /2 2" "3 31 1/ /4 4" "4" 25/ /32 32" " 4" 4 43 3/ /8 8" " 7 7/ /16 16" " 1 17 7/ /32 1 15 5/ /8 8" "2 27 7/ /8 8" "3 35 5/ /8 8" " insert 7 7/ /16 16" " 16" " Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  8. COLUMN Technical Information 08 COLUMN Floor Bracket Detail 08 Fixing Brackets (supplied with every radiator) - Wall Brackets Floor Bracket SK (Optional) 50 30 Complete system for free-standing radiators, from 2-6 column up to 1000mm height. Painted to RAL 9016. 16 20 Includes: Includes: - 3mm thick base-plate for fixing to either finished or unfinished floor Two-part cover for base-plate in white plastic 45/16" x 55/16" 10.5 5 6 14 - upright support 35 x 10 x 1.5mm, fixing set with adjustable bracket, security fixing, anti-vibration insert 6.5 8.5 18 6 59 83 - adjustable bottom support with spacer and anti-vibration insert, white plastic end stop for top of upright. 39/16" security fixing, 20.5 14 4.5 34.5 215/16" 43/32" 15 Height of Upright Height of Radiator 3.6 5/16" Order Code 49/16" 17 12 ?? ?? ?? ? ?? ?? ??? ?? ?? ?? ? KOM-ASK2 18" 24" 30" Base-Plate Cover 12" 18" 24" Dimensions of base-plate for Floor Bracket SK 20 Radiator Brackets A (see table below) Ensure tight fit here 19 32.5 Type 2 to 4 Column The table on the right gives recommendations for the number of brackets to be used with each radiator. Number of Sections 21 - 40 0 - 20 62 11 Up to 39” Height: Wall - Mounted Angle Brackets - RW Radiator Bracket - RH 13 Radiator Bracket 4 6 The strength of the wall should be checked for its load-bearing capabilities before installation. 6 4 25 Angle Wall Bracket 11.5 11 Floor Mounting Floor bracket - SK 20 2 3 30 A = Distance between Wall & Centre 2 column 3 column Wall & Bracket Wall Bracket & Radiator Bracket Wall & Radiator Over 39” Height: Wall - Mounted Angle Brackets - RW Radiator Bracket - RH 4 column 20mm 11mm 31mm 62.5 81.5 100.5 30mm 11mm 41mm 72.5 91.5 110.5 insert 4 4 6 6 Connections All MYSON COLUMN radiators are fitted with 4 x 1/2 inch BSP connections. blue. It is important that the water inlet is connected to the tapping identified in red. Radiators include plug and vent. N.B. The radiator is suitable for the use of BBOE (Bottom Bottom Opposite End), TBSE (Top Bottom Same End) and TBOE (Top Bottom Opposite End) connections. TTOE (Top Top Opposite End) connections cannot be used. Radiators are manufactured with an internal baffle. The tapping with the baffle is identified with a red plastic cap, all others being Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  9. COLUMNSizes & Outputs 09 COLUMN Sizes & Outputs 11 4in 51/2 in 21/2 in 2 COLUMN 3 COLUMN 4 COLUMN Architecture Range - Bench Radiator 2 COLUMN Order Code Length (in) Length inc. seat (mm - inches) Height inc. seat (mm - inches) Depth inc. seat (mm - inches) Output (watts) Output (Btu/h) Water Content (gals) Weight (lbs) No. of Sections Output (Btu/h) Order Code 1.68 2.24 2.80 3.36 3.92 5.00 24 32 40 48 56 72 1847 2462 3078 3693 4309 5540 19.8 26.5 33.0 39.6 46.2 59.4 12 - 2045 16 - 2045 20 - 2045 24 - 2045 28 - 2045 36 - 2045 12 16 20 24 28 36 1850 - 73 1850 - 73 2150 - 85 2150 - 85 2350 - 93 2350 - 93 472 - 19 522 - 21 472 - 19 522 - 21 472 - 19 522 - 21 365 - 14 365 - 14 365 - 14 365 - 14 365 - 14 365 - 14 1489 1738 1816 2119 2053 2396 5080 5930 6196 7230 7005 8175 23 SEC 056150 23 SEC 066150 23 SEC 056180 23 SEC 066180 23 SEC 056200 23 SEC 066200 Height 18in 2.10 2.80 3.50 4.20 4.90 24 32 40 48 56 2448 3265 4081 4897 5713 25.9 34.6 43.2 52.0 60.5 12 - 2060 16 - 2060 20 - 2060 24 - 2060 28 - 2060 12 16 20 24 28 Height 24in 12 16 20 24 30 3.00 4.02 5.02 6.02 7.53 4041 5388 6735 8082 10103 41.4 55.2 69.0 82.8 103.5 6 - 2200 8 - 2200 10 - 2200 12 - 2200 15 - 2200 6 8 The Bench Radiator is sold complete, but can be sold seperately if required. Height 79in H 10 12 15 Special order only. L 3 COLUMN Accessories Order Code Water Content (gals) Weight (lbs) Length (in) No. of Sections Output (Btu/h) 2.42 3.02 4.23 5.44 32 40 56 72 2380 2975 4265 5355 27.5 34.4 48.2 62.0 16 - 3030 20-3030 28-3030 36-3030 16 20 28 36 Height 12in e Cleaning Brush Towel Rail Decorative Foot Clip-on rail to fit all radiators up to 1m long (20 sections) Product Code: COLDECFOOT Micro Fibr 2.41 3.22 4.02 4.83 5.63 7.24 24 32 40 48 56 72 29.6 39.5 49.4 59.3 69.3 88.9 2674 3565 4456 5347 6239 8021 12-3045 16-3045 20-3045 24-3045 28-3045 36-3045 12 16 20 24 28 36 Height 18in Product Code: COLUMNBRUSH2 Product Code: 12SECRAIL 16SECRAIL 20SECRAIL 3.00 4.02 5.02 6.02 7.53 24 32 40 48 56 3566 4755 5944 7132 8321 41.4 55.2 69.0 82.8 103.5 12-3060 16-3060 20-3060 24-3060 28-3060 12 16 20 24 28 Height 24in Fixing Brackets Floor Brackets Product Code: FK1021 Product Code: COVERFK Product Code: SK20046 4 COLUMN Product Code: SK20061 Order Code Water Content (gals) Weight (lbs) Length (in) No. of Sections Product Code: SK20076 Output (Btu/h) 4.00 5.33 6.67 8.00 24 32 40 48 4213 5618 7022 8426 51.6 68.8 86.0 103.2 12 16 20 24 12 - 4060 16-4060 20-4060 24-4060 Height 24in Product Code: SK20091 Product Code: COVERSK NOTE NOTES S: : 1. All dimensions are nominal. 2. Heat outputs are based on 180 temperature of 1120F) 3. For heat outputs at other temperatures see page 13. 1800 0F AWT F AWT and 680F EAT (mean water to air Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  10. COLUMN Sizes & Outputs 10 BENCH Sizes & Outputs 10 63 mm 101 mm 139 mm Architecture Range - Bench Radiator 2 COLUMN 3 COLUMN 4 COLUMN Rough - in (cc) Water Content (gals) 3.75 4.49 4.41 5.28 4.52 6.50 5.34 7.64 5.90 8.42 Radiator Length Dimensions (in) LxHxW Order Code Output (Btu/h) Weight (lbs) No. of Sections (in) (in) 2 COLUMN 53 x 19 x 14 53 x 21 x 14 61 x 19 x 14 61 x 21 x 14 73 x 19 x 14 73 x 21 x 14 85 x 19 x 14 85 x 21 x 14 93 x 19 x 14 93 x 21 x 14 3528 4231 4185 5022 6452 7530 7868 9182 8895 10383 23-05-6100 23-06-6100 23-05-6120 23-06-6120 23-05-6150 23-06-6150 23-05-6180 23-06-6180 23-05-6200 23-06-6200 5 6 5 6 5 6 5 6 5 6 393/8 393/8 47 1/2 47 1/2 59 1/16 59 1/16 70 7/8 70 7/8 78 3/4 78 3/4 3613/16 3613/16 44 11/16 44 11/16 75 87 85 99 Length (mm - inches) No. of Sections Output (watts) Output (Btu/h) Order Code 600 - 24 12 800 - 32 16 1000 - 40 20 1200 - 47 24 1400 - 55 28 1015 1800 - 72 36 1305 435 580 725 870 1485 12 SEC 2045 1980 16 SEC 2045 2474 20 SEC 2045 2969 24 SEC 2045 3464 28 SEC 2045 4454 36 SEC 2045 561/2 561/2 146 161 172 190 186 205 Height 450 mm 685/16 685/16 763/16 763/16 600 - 24 12 800 - 32 16 1000 - 40 20 1200 - 47 24 1128 1400 - 55 28 1317 564 752 940 1925 12 SEC 2060 2567 16 SEC 2060 3209 20 SEC 2060 3850 24 SEC 2060 4492 28 SEC 2060 Height 600 mm Technical cal Data a X 300 - 12 400 - 16 500 - 20 10 1468 600 - 24 12 1762 750 - 30 15 2202 6 8 1175 881 3006 4008 5010 10 SEC 2200 6012 12 SEC 2200 7515 15 SEC 2200 6 SEC 2200 8 SEC 2200 13/8" Height 2000 mm 3" 315/16" 3 COLUMN A Length (mm - inches) No. of Sections Output (watts) Output (Btu/h) Order Code 800 - 32 16 1000 - 40 20 1400 - 55 28 1800 - 71 36 1274 566 708 991 1933 16 SEC 3030 2416 20 SEC 3030 3382 28 SEC 3030 4348 36 SEC 3030 Thermostat Height 300 mm 600 - 24 12 800 - 32 16 1000 - 40 20 1010 1200 - 47 24 1212 1400 - 55 28 1414 1800 - 72 36 1818 606 808 2068 12 SEC 3045 2757 16 SEC 3045 3446 20 SEC 3045 4135 24 SEC 3045 4825 28 SEC 3045 6203 36 SEC 3045 Y Height 450 mm 600 - 24 12 800 - 32 16 1042 1000 - 40 20 1302 1200 - 47 24 1562 1400 - 55 28 1823 781 2665 12 SEC 3060 3554 16 SEC 3060 4442 20 SEC 3060 5331 24 SEC 3060 6219 28 SEC 3060 Detail "A" 149/16" Height 600 mm 15/16" 1/2" Valve Body 600 - 24 12 800 - 32 16 1270 1000 - 40 20 1588 1200 - 47 24 1906 1400 - 55 28 2223 935 3251 12 SEC 3075 4335 16 SEC 3075 5418 20 SEC 3075 6502 24 SEC 3075 7586 28 SEC 3075 Thermostat Height 750 mm H Floor Brackets 55/16" 55/16" Product Code: SK20046 4 COLUMN Product Code: SK20061 Length (mm - inches) No. of Sections Output (watts) Output (Btu/h) Order Code 1113/16" Product Code: SK20076 13/16" 600 - 24 12 800 - 32 16 1330 1000 - 40 20 1662 1200 - 47 24 1994 1400 - 55 28 2327 997 3402 12 SEC 4060 4537 16 SEC 4060 5671 20 SEC 4060 6805 24 SEC 4060 7939 28 SEC 4060 Product Code: SK20091 Height 600 mm Radiator Length - 2 9/16" Product Code: COVERSK 23/4" Radiator Length +13 34" 215/16" 600 - 24 12 1214 800 - 32 16 1619 1000 - 40 20 2024 1200 - 47 24 2429 1400 - 55 28 2834 4144 12 SEC 4075 5525 16 SEC 4075 6906 20 SEC 4075 8287 24 SEC 4075 9668 28 SEC 4075 Height 750 mm 315/16" Radiator Lenth +1 3/8" NOTE: NOTE: All dimensions are nominal. Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  11. RADIATORoptional piping arrangements 11 Typical hydronic system types The following drawings are general examples. Consult a certified heating professional for your specific application. Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  12. RADIATORvalve selection 12 Valve application   All installations require 2 valves per radiator All valves are ½” BSP thread ½” BSP thread for connection to the radiator ½” NPT thread ½” NPT thread for connection to the system and ferrule and ferrule for connection to ½” copper 2 valves per radiator to the radiator and includes compression nut to the system (also includes compression nut   Valves are available in 3 basic patterns: angle, straight, and inverted angle (TRV only) Basic Installation Basic Installation: use 2 – LKD16AN LKD16AN (angle) or LKD16SN manual valves, nickel plated with screwdriver stops and caps LKD16SN (straight)  Basic upgrade Basic upgrade: use 1 ‐ FF16WAC only, chrome plated with white handles (FF16WAC is adjustable for balancing, FF16LAC is fixed open but can be closed for service) FF16WAC and 1 – FF16LAC FF16LAC manual valves, angle  TRV TRV (thermostatic radiator valves) are available for automatic temperature control of individual radiators: available in 3 body patterns, with or without thermostatic head (sensor), use in conjunction with LKD or FF with LKD or FF use in conjunction   TRV TRV remote sensors and adjusters available for special applications DCK12 DCK12 – 4” chrome nipple with compression connection available for use with all Myson valves, includes escutcheon (connects valve to heating system)   DAV12 DAV12 – same as DCK12 with Decorative pipe covers and escutcheons available in chrome or white (use to cover exposed copper pipe used in radiator installation) with addition of integral ball stop angle valve integral ball stop angle valve    LKD16AN     LKD16SN    FF16WAC      FF16LAC    TRV angle w/HEAD  Remote Sensor      Remote Adjuster     TRV straight    TRV inverted angle      TRV HEAD only  DCK      DAV  Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  13. COLUMN Conversion Factors / Start-up & Maintenance 13 Heat output factors / Start - up and Maintenance Heat Output The heat outputs for all MYSON COLUMN 10. The tabulated figures are quoted in accordance with EN 442 for a mean water to air temperature of 1120F. This is based on an average water temperature of 1800F and an ambient air temperature of 680F. When the difference is not 1120F, the output should be multiplied by the appropriate factor from within the table below: MYSON COLUMN radiators can be found on pages 9 and Water to Air (Delta T 0F) Aver. Water Temp. 0F Ambient Air Temp. 0F Conversion Factor 1.14 122 112 102 92 82 72 52 190 180 170 160 150 140 120 68 68 68 68 68 68 68 1.00 .91 .79 .68 .58 .38 SYSTEM START-UP SYSTEM START-UP Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty. Step 1 Fill and vent the system. Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position. Step 3 Shut off and drain the system while the water is still hot. Step 4 Refill the system. Step 5 Reheat, vent, and balance the system. Step 6 Once the Décor Radiator is filled with water the system should be left filled. Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally. MAINTENANCE & CLEANING 1Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion. 2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of your Myson Décor Panel Radiator. 3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty. Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  14. NOTES 14 Notes Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  15. 15 NOTES Notes Myson Inc./Rettig USA Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com www.mysoncomfort.com

  16. MYSON Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com heatingthroughinnovation. COLUMN 7/2016

More Related