An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CERN, 1th February 2011 Magnetic model ACTIVITES FOR 2011 E. Todesco CERN, Geneva Switzerland

  2. GENERAL TOPICS • Energy stays at 3.5 TeV • Cross-check of settings needed [P. Hagen] • Hysteresis removed [M. Strzelczyk] • Check that it behaves as expected • Beta* will go down to 1.5 m • Beta beating will probably be an issue over there • Corrections from measurements [R. Tomas] to be checked vs field model

  3. Tune • Tune decay at injection • Rather large (up to 0.05 over 10 h) – since previous trims are used in the next run this can drive tune on resonances • A correction based on measurements is proposed[N. Aquilina] and implemented [M. Strzelczyk] Horizontal tune drift duringramp[N. Aquilina]

  4. Chromaticity • Chromaticity decay at injection • Rather large 10-15 units • Correction based on measurements will be proposed [N. Aquilina, W. Venturini] • The scheme to correct during injection is already implemented [M. Strzelczyk]

  5. Chromaticity • Chromaticity during ramp • In 2010 controlled within 15 units • We should do better this year: target of a factor 2 improvement Decay at 3.5 TeV Static model Chromaticityduring the 10 A/s ramps , 6 cases blue: horizontal - red: vertical [R. Steinhagen]

  6. VAN DER MEER SCANS • During Van der Meer scans to calibrate luminosity a relevant hysteresis has been observed [M. Ferro-Luzzi] • Possibly related to MCBY, used to make the scan • To be investigated: this could improve the precision of the calibration