Review of LOFW

Review of LOFW. LOFW category. In VVER-1200 designs these PIEs are design basis conditions of Category 2 (anticipated operational occurrences, frequency 0.01 per year or more). Comment: acceptable but need details as the following. Acceptance criteria.

kalona
Télécharger la présentation

Review of LOFW

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Review of LOFW

  2. LOFW category • In VVER-1200 designs these PIEs are design basis conditions of Category 2 (anticipated operational occurrences, frequency 0.01 per year or more). • Comment: acceptable but need details as the following

  3. Acceptance criteria • Pressure of the primary coolant and SG steam lines will be less than 115 %of design value of design value; • DNB is not reached DNB is not reached with a probability of 95% for the most hot fuel rod (minimum DNBR in the core is more than (minimum DNBR in the core is more than 1.0); - Acceptable • Fuel pellets do not melt even locally (temperature is lower than 2540°С for “burnout” fuel and less than 2840°С for fresh fuel); - Inconsistent with graph (1818 °С ??) and not stated in calculation result • Radially-averaged fuel enthalpy does not exceed 586 J/g along the J/g along the axis of any fuel rod – Prove??

  4. Computer Codes • The LOFW calculation is made with the use of computer code DINAMIKA-97 included into the computer code package TRAP-97 described in section 15.3. The code package TRAP-97 is validated against large scope of domestic and international experimental data and certified by Russian regulatory body. • Comment: Acceptable

  5. Thank you