Training Course SuperCool 1000 Level 1

Training Course SuperCool 1000 Level 1. Course #P0131. Contents. Module 1: Introduction Module 2: Inputs and Outputs Module 3: Features Exam. LCD display for ease of programming. LED display readable at a distance. Manual switch for mist. Pilot lights indicate status of

kamuzu
Télécharger la présentation

Training Course SuperCool 1000 Level 1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Training CourseSuperCool 1000 Level 1 Course #P0131

  2. Contents • Module 1: Introduction • Module 2: Inputs and Outputs • Module 3: Features • Exam

  3. LCD display for ease of programming LED display readable at a distance Manual switch for mist Pilot lights indicate status of controller outputs 75.4 M1 Tº 72.0 ºF Pr. Act: 123456 Rapid-access function keys

  4. System • Controls the operation of a high pressure nozzle system by keeping track of humidity and temperature levels. • The high pressure nozzle system is the one sold by Victoria Equipment. • Controls stir fans. • Dairy cows are the main application. It can also be used for poultry and hog production. Click on image to view video.

  5. What the Client Gets • Controller; • 1 temperature probe; • Contactor box for pump; • Instruction manual / wiring diagram. Product Options • Up to 3 relative humidity sensors; • Indoor or outdoor temperature probes; • Valve; • Pressure switch; • Water meter; • Configuration module; • Comlink-1 for communications (Bridge)

  6. Module 2: Controller Inputs and Outputs

  7. 6 x indoor Tº probes 1 x outdoor Tº probe 3 x indoor relative humidity sensors 1 x water meter 1 pressure switch 1 mist output 1 pump 1 mist valve 1 drain valve 3 fan groups. Inputs and Outputs

  8. Input: Relative Humidity Sensors • You can select sensors to use. • Allows for various strategies: • Misting: • Compensation on pump operating times; • Stop pump if RH too high. • Operation of fan groups according to RH level • History record over 7 days for minimum and maximum values.

  9. Output: Mist • Operates according to 4 intensity levels. For each level, user must indicate: • Start and stop temperature; • Timer settings. • For example: Intensity

  10. Output: Mist (cont’d) • Depending on RH level, controller will modify timer operating times in 2 ways: • Humidity lower than comfort zone: Time Off is decreased • Humidity higher than comfort zone: Time On is decreased Current Current 50% = % Time Off 50% = % Time On RH Comfort Zone No compensation Pump will operate for a shorter period Pump will stop for a shorter period Max Compensated Max Compensated %RH 90% 50% 60% 80% Low RH set-point High RH set-point

  11. Output: Mist (cont’d) • Mist operation can be shut off: • If RH level too high; • During the night. • Mist can be activated if RH too low (dust control)