Electrical Cable Aging and Condition Monitoring Codes and Standards for Nuclear Power Plants

Electrical Cable Aging and Condition Monitoring Codes and Standards for Nuclear Power Plants. Electrical Cable Task Group (ECTG) NESCC Update: 7 November 2013 Co-Chairs: Dr. Stephanie Watson, NIST Dr. Corey McDaniel, R-SCC. ECTG Scope. Objectives:

keanu
Télécharger la présentation

Electrical Cable Aging and Condition Monitoring Codes and Standards for Nuclear Power Plants

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electrical Cable Aging and Condition Monitoring Codes and Standards for Nuclear Power Plants • Electrical Cable Task Group (ECTG) • NESCC Update: 7 November 2013 • Co-Chairs: • Dr. Stephanie Watson, NIST Dr. Corey McDaniel, R-SCC

  2. ECTG Scope Objectives: • Inventory of relevant standards with gaps and overlaps analysis. • Recommendations for revisions or new electrical cable standards. • Review of current citations of electrical cables codes and standards in NRC regulatory documents. • Short, Medium, and Long-term Recommendations

  3. Status and Path Forward • July: • Added task group co-chair from industry. • Draft report submitted to Steering Committee for review and comment. • Task group co-chair facilitating review and update of draft report by industry. • October: • Draft final report to NRC and DOE for final comments • November: • Publication.

  4. RECOMMENDATIONS • Short-Term Actions (<3 year) • Revise RG 1.89 Revise RG 1.189 • NRC provide guidance on RG 1.1.31 • Cable aging studies • Research on adequacy of cable characterization techniques • Low smoke zero halogen research • Medium-Term Actions (3 to 8 years) • Revise RG 1.218 • Research on water submergence • Research on activation energy • Definitions of low and medium voltage • Long-Term Actions (> 8 years) • Correlation between accelerated exposure and natural aging conditions

  5. EMERGING ISSUES: Korea • Background • June 2013 – NSSC reveals cable falsifications, 4 reactors shutdown • More than 100 officials have been indicted to date; KHNP CEO, Minister • Reactor head cables removed and replaced using domestic supplier • Cable in two new reactors was “re-tested” – APR-1400 (UAE ref. plants) • Testing conducted in October – cables failed flame tests, must be removed • KHNP issues ITB two days later; 20 KHNP executives dismissed • 2 U.S. companies are the only invited bidders (domestic not allowed) • Bids accepted last Friday (1 November); award expected 2-3 weeks • Implications • Korea used IEEE to “re-test” cables; are “re-test procedures” needed? • Will cables at other reactors be re-tested as a result of Korea? • Will re-testing expand beyond Korea? • Research implications of re-testing, beyond condition monitoring?

  6. Gaps in Research and Standards Existing NPPs • Cable Aging Studies • Accelerated aging and extrapolation to 60 years • Thermal and radiation sequence • Diffusion limited oxidation • Water Submergence and its Effects • Medium versus low voltage • Activation Energy Determination • Adequacy of Cable Characterization Techniques • Destructive versus non-destructive • Line Resonance Analysis (LIRA) • Low voltage cable applications; SDOs need to develop a method • Currently used in NPPs (I&C, power), T&D, Wind Parks (on/offshore), Process Industry, Oil and Gas Industry (above ground, underground, submarine, umbilical cables), Cable Manufacturers (reference measurements, QC) • Joint Time and Frequency Domain Reflectometry • Cable field tests for non-shielded cables (5 kV and above) • Universal procedure for walk-downs of cable installations

  7. Gaps in Research and Standards New NPPs • Qualification testing on low smoke zero halogen cables • Performance correlation between fast non-oxidative diffusion limited oxidation controlled exposure (IEEE 323) with oxidatively driven materials degradation for long term plant normal operation (low dose radiation and low temperature) • Commonly accepted definitions of low and medium (action for SDOs)