An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cables, Plates & Onlay Allografts Mark Ashworth Torbay Hospital

  2. Cables, Plates & Onlay Allografts • Guide you through the ‘menu’ • Discuss the merits of the various ‘dishes’ • Perhaps make a recommendation or two • Set the scene for the ‘main course’ to follow

  3. Cables

  4. Cables • Current indications • Prophylactically • Increased hoop stress resistance (Tsiridis, 2003) • Temporary • Stabilisation pending plate, strut, THR insertion • Definitive • Simple periprosthetic # - alone • Calcar splits on insertion • B1 spiral # • Complex periprosthetic # - with other devices • Plates, mesh, impaction or strut graft…. • Contra-indications • Transverse/short oblique periprosthetic # (poor torsion/bending rigidity)

  5. Symmetrical Wire twist wrap Square knot AO loop & tuck AO Loop Double loop Cables a – Stainless Steel wire Knot twist • Knot Strength • Thicker wire = stronger knots(Wilson 1985) • >2 twists = NO increase in strength(Schultz 1985) • Double loop knot strength > square knot > twist(Roe, 1997 & 2002) • Simple twist easily untwists with little tension(Meyer 2003) • Knot twist 100000 cycle fatigue stronger>twist(Bostrom 1994)

  6. Cables b - Multi filament • Cable material • Zimmer & Biomet - Stainless steel, cobalt chrome & titanium • De puy - Stainless steel 1.8mm • Dall Miles - Stainless steel & Cr Co Mo (vitallium) • Cable strength • Fatigue – cables superior to SS wire (Weiss 1996) • Ultimate strength – 1 cable > 1 wire (Carls 1997); but 1 cable = 2 wires (Liu 1997) • Chrome cobalt > stainless steel • Cable cost • Double loop cerclage ~10x less £££££ than cables (Ritter2006)

  7. Cables c - Nylon • Nylon core, UHMWPesheath (Ti/Al/V clasp - some Cr Co) • Contraindication if can catch on mesh or plate edge (Kinamed) • Elastic energy stored after initial relaxation • Iso-elastic cable maintains continuous compressive forces = initial compression of cerclage wires • Compensates for # movement & decreased risk of cable slip

  8. Cables c - Nylon • Ultimate strength

  9. Cables c - Nylon • Fatigue strength Breakage in cabling systems are generally fatigue failure not tensile failures

  10. Plates

  11. Plates • “2B or not 2B, that is the question” • Lindahl 2006 Swedish register 245 cases- • Single plate ORIF higher risk of failure with B1# • #’s were probably un-recognised B2 (revision best) • Prosthesis considered loose until proven otherwise • Infer…..’ no place for fixing #, then later revising stem ‘

  12. Plates • Non locked • Locked • Cable plate systems • Dall Miles 1983

  13. Platesa- Non Locking plates • Ogden (1978) -Proximal cables, distal screws • Plate & screws (in vitro) > Ogden > 2 struts > cabled plate • Clinical results = 80% good/union • Standard plate- All Screws • 90 : 90 plating = best biomechanics • Soft tissue strip++ • 90% union with broad DCP

  14. Old 2006 Rx Platesa- Non Locking plates • Old 2006 • 95 % union ( no bone graft/strut) • Long plate for proximal screw fixation • +/- cerclage wires • Their technique = Haddad 2002 results • used strut allograft or strut & plate • MIPPO B1 # • Indirect ORIF 1 lateral plate no bone graft • ~12/52 86% union • 100% (Abhaykumar 2000, Ricci 2005) • Adjuvant bone graft not always necessary (Ricci 2007)

  15. Platesb- Locking plates • Stiffer than Ogden, & fail by lat cortex fracture(Fulkerson 2006) • Conventional outermost screw reduces stress riser & significantly increased strength(Bottlang 2009) • 90:90 construct (plate or strut) (Talbot 2008) • Stiffer than 1 plate • Locking screws give no mechanical advantage over conventional screws • No cable loosening after 100,000 cycles

  16. Platesb- Locking plates • C# & B1# • 100% union • LCP • MIPPO • 90% union • LCP • LISS technique difficult but fewer complications than traditional fixation • Better results IF combined with struts

  17. Sit in screw head Platesc- Cable plates • B1 # • 100% union 4/12 • 85% union • 57% union, cabled Dall Miles – ‘consider strut or long stem’ • 40% successful union, ‘avoid in varus stem’ • Avoid if retaining a stem in varus • Threaded pin cerclage better than cerclage plate wrap

  18. PlatesScrew angles d D • DCP • Offset hole 4mm on broad BUT not narrow plate • 250 & 70 screw angle

  19. PlatesScrew angles • DCP • Offset hole 4mm on broad BUT not narrow plate • 250& 70screw angle • LC-DCP • 800 & 140 screw angle, 4mm offset D

  20. PlatesScrew angles • DCP • Offset hole 4mm on broad BUT not narrow plate • 250& 70screw angle • LC-DCP • 800& 140screw angle, 4mm offset • Locking CP • 500 (<DCP) and 140 non locked screw angle • 4mm offset

  21. 570 160 PlatesScrew angles • DCP • Offset hole 4mm on broad BUT not narrow plate • 250& 70screw angle • LC-DCP • 800& 140screw angle, 4mm offset • Locking CP • 500 (<DCP) and 140 non locked screw angle, 4mm offset • Kinamed Supercable • 570 & 160 nonlocked screw angle, 4mm offset • Curved plates (match femur) D+

  22. Plates • Mennen

  23. Plates • Mennen • Ahuja 2002 75% complication rate • Noorda 2002 mechanical failure 31% and non-union 28%

  24. Onlay Allograft

  25. Onlay Allograft • Current indications • Restore bone loss • Uncontained non-circumferential defects • As a ‘Plate’ • Reinforce bone loss areas & bypass stress risers • Fix periprosthetic fractures • Stabilize bulk allograft : host junctions

  26. Onlay AllograftTechnique • 1st description • Penenberg & Chandler 1989 • Chandler 1998 • Struts ½ diameter of shaft • Med & lat placement, contour to fit shaft • To avoid stress riser plate/allograft should be staggered & bypass # by 2 diameters • Avoid linea aspera to protect blood supply • Keep periosteum for blood supply • Cables x 6 minimum • Bradey 1999 • 1/3 diameter @ 90:90 anterior & lat • Preserves b.s from linea aspera & reduced stripping

  27. Onlay AllograftBiology of union • Bone resorption • Variable rounding off & scalloping by 6 months • Bridging • Partial at 8/12 , completed by 1 yr • Partial revascularisation • 20% by 5 years • Diffuse loss of radiodensity & changed trabecular pattern • Remodelling • Of the graft & host femur

  28. Onlay AllograftBiology of union • Union rate • Improves if rigid fixation • 11-20% fail -infection, rejection, fracture, non union • Union speed/quality • Auto graft - better quality union but not faster • Osteogenic protein 1 - faster healing & better quality • BMP2 - faster healing & better quality • Immune response • Reduces osteoinduction • Freezing reduces antigenicity

  29. Onlay AllograftBio-mechanics • Bone strength • Freezing > freezing & irradiation > freeze drying • Dead bone > repaired bone (resorption)……… • Allograft fractures increase around 2-4 years • Stress shieldingin vitro • Plate > strut

  30. Onlay AllograftResults • Plate & strut better than strut alone • 90 - 95% union, strut alone • 95% union, 1 plate 1 strut • 98% union, struts +/- plate

  31. My Recommendations:-

  32. My Recommendations:- • Wire • Temporary use – thickness & knot type is unimportant • Definitive use – if run out of cables simple B1 or C# (with great caution)

  33. My Recommendations:- • Wire • Temporary use – thickness & knot type is unimportant • Definitive use – if run out of cables simple B1 or C# (with great caution) • Cables • MUCH better than wire, but best used with plates • Nylon cables have some theoretical advantages in more complex # pattern • movement compensation; but costs more

  34. My Recommendations:- • Wire • Temporary use – thickness & knot type is unimportant • Definitive use – if run out of cables simple B1 or C# (with great caution) • Cables • MUCH better than wire, but best used with plates • Nylon cables have some theoretical advantages in more complex # pattern • movement compensation; but costs more • Plates • Cabled plates good enough • Broad plates with all screws (offset screw holes) are better • Locked plates best • MIPPO difficult but results worth the effort

  35. My Recommendations:- • Wire • Temporary use – thickness & knot type is unimportant • Definitive use – if run out of cables simple B1 or C# (with great caution) • Cables • MUCH better than wire, but best used with plates • Nylon cables have some theoretical advantages in more complex # pattern • movement compensation; but costs more • Plates • Cabled plates good enough • Broad plates with all screws (offset screw holes) are better • Locked plates best • MIPPO difficult but results worth the effort • Strut graft • Almost as good as locked plates clinically

  36. My Recommendations:- • Wire • Temporary use – thickness & knot type is unimportant • Definitive use – if run out of cables simple B1 or C# (with great caution) • Cables • MUCH better than wire, but best used with plates • Nylon cables have some theoretical advantages in more complex # pattern • movement compensation; but costs more • Plates • Cabled plates good enough • Broad plates with all screws (offset screw holes) are better • Locked plates best • MIPPO difficult but results worth the effort • Strut graft • Almost as good as locked plates clinically 90:90 configuration, although stronger bio-mechanically, clinically probably not necessary.

  37. Thank You