Monjur Mourshed Building Energy Research Group Loughborough University

Sub-hourly electricity demand November 2011-March 2012. Managing energy demand from buildings Profile, energy efficiency and the effects of climate in Bangladesh. Monjur Mourshed Building Energy Research Group Loughborough University. Project details.

kent
Télécharger la présentation

Monjur Mourshed Building Energy Research Group Loughborough University

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sub-hourly electricity demand November 2011-March 2012 Managing energy demand from buildingsProfile, energy efficiency and the effects of climate in Bangladesh Monjur MourshedBuilding Energy Research GroupLoughborough University

  2. Project details • 3 year research project, funded by the British Council • Project partners • Rob Wilby, Department of Geography, Loughborough University • FuadMallick, Department of Architecture, BRAC University • Aims • Assess the impact of built environment on energy demand • Investigate the impact of changing climates • Develop a framework for resilient built environment in Urban Dhaka, considering: • Energy • Human comfort and wellbeing

  3. Power outage in Dhaka Dhaka during blackout Overlooking Mohakhali 02 April 2012 Immediately before blackout

  4. Context: Energy demand and generation High speed diesel (10.19%) Hydro Coal Heavy fuel oil (5%) Furnace oil 7% pa 33.7 GW 7.5 GW Gas (76%)

  5. Sub-hourly demand and generation profiles

  6. Sub-hourly shortage (outage) profile

  7. Hourly demand vs. generation profile March weekday 29/3/2012 December weekday 21/7/2012 March weekend 29/3/2012 December weekend 21/7/2012

  8. How do people cope with outages?

  9. Coping with outages: Energy storage and gen. systems Commercial Diesel gen-sets UPS Domestic Diesel gen-sets EPS – Backup power supply (~.5-1 hr)

  10. Simulation: Investigating the effects of glazing on lighting • Typical mid-rise • Location: Banani • Single leaf construction • Different glazing types • Typical office occupancy

  11. Effect of glazing type on daylighting availability Single Clear 6mm SHGC: .810 LT: .881 U-value: 6.121 Double Clear 6mm – Argon - 13mm SHGC: .698 LT: .781 U-value: 2.549 • South zone • Model parameters: • CIE clear sky • 21 July at noon Single Tinted 6mm SHGC: .427 LT: .251 U-value: 6.066 Double Low E (e=2.1) 6mm – Argon - 13mm SHGC: .564 LT: .745 U-value: 1.499

  12. Reducing lighting energy during the day: Effect of glazing South zone North zone

  13. Increasing temperature and demand for cooling

  14. Changes in mean daily temperature: More warming during winter

  15. Projected increases in cooling degree-days ~ cooling energy consumption

  16. Concluding remarks

  17. Thank you Project website: http://www.adaptablecities.org/