1 / 41

Picosecond Timing Resolution with Scintillators for HEP Detectors and TOF PET Scanners

This work focuses on the importance of fast timing and high-resolution detection in the field of high-energy physics (HEP) and time-of-flight (TOF) PET scanners. It explores the use of picosecond timing resolution for improving particle identification, energy resolution, and TOF techniques. The potential applications include TOF PET scanners with enhanced sensitivity, CT X-ray imaging, imaging in turbid media, and hyperspectral time-resolved spectroscopy.

kimb
Télécharger la présentation

Picosecond Timing Resolution with Scintillators for HEP Detectors and TOF PET Scanners

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Picosecond timing resolution with scintillators for a new generation of HEP detectors and Time-of-Flight PET scanners Paul Lecoq CERN, Geneva This work and presentation are made in the frame of the ERC Advanced Grant Agreement N°338953–TICAL

  2. Why fast timing? 1/5 sec 1/500 sec 1/5000 sec

  3. Why 10ps timing resolution • Time-of-Flight techniques to alleviate the pile-up problem and help improving energy resolution at high luminosity colliders • Improve resolution of finely segmented homogenous calorimeters • Time-of-Flight PET sanners with > 10 fold improvement in sensitivity • CT X-Ray imaging • Imaging in turbid media • hyperspectral time resolved spectroscopy for high precision dynamic studies of fast phenomena

  4. Detection of ionizing radiationWhat matters? TOF When Where Energy Particle ID Finely segmented calorimeters

  5. HEPPrinciple of pile-up mitigation For a luminousregiondistributed over ~ 10cm, collisions willbe distributed over ~ 300ps Use the tracker to determine the z position of the vertex (large angle tracks) Use TOF to associate a time to a vertex Requires 10ps timing resolution !!!

  6. HEP: CMS timing layer 248’832 LYSO/SiPM The CMS Collaboration, TechnicalProposal for a Mip Timing Detector in the CMS Experiment Phase 2 Upgrade, CERN-LHCC-2017-027 ; LHCC-P-009

  7. CMS timing layer: beam tests with mip’s ≈ 5 MeV ≈ 3 MeV ≈ 3 MeV 30 ps SmallerSiPM / crystal area coverage A.Benaglia, M. Lucchini et al., NIM 830 (2016) 30

  8. Hadron energy deposition in a segmented hadron calotimeter Global time t Local time t-z/c 50GeV proton in a 1x1x3m3 iron block segmented in 1mm thick layers About 1 MeV/mip/layer A. Benaglia, E. Auffray, P. Lecoq, H. Wenzel, A. Para, IEEE Trans. Nucl. Sc. VOL. 13, NO. 9, Sept. 2014

  9. Dual Gate (scintillation) vs Dual Readout (Scint. + Cher.) A. Benaglia, E. Auffray, P. Lecoq, H. Wenzel, A. Para, IEEE Trans. Nucl. Sc. VOL. 13, NO. 9, Sept. 2014

  10. Time of Flight PET Dt = tA – tB = [(d+d1) – (d-d1)]/c Detector B d1 = c Dt/2 tB d d1 Patient e+ 10ps TOF resolution dx = 1.5mm SNRTOF/SNRCONV= 16! e- tA SNRTOF = √(2D/cDt) · SNRconv Detector A dt (ps) dx (cm) SNR* 10 100 300 500 0.15 1.5 4.5 7.5 16 5.2 3.0 2.3 State-of-the-art * SNR gain for 40 cm phantom

  11. Why 10ps TOFPET? • TOF for direct 3D information • Requires10ps TOF resolution for 1.5mm resolutionalong LOR • Allowslimited angle tomographywithoutartifacts • > 15-fold improvement in S/N ratio, even more with high random rate • Equivalent potential in dose reduction (0.5mSv/scan) • Annualnatural background: 2.4mSv • Return flight Paris SFO: 0.11mSv • Allows longer longitudinal studies per injection • Reduce the cost of radiotracer production infrastructures • Less sensitive to incorrect attenuation correction and normalization • Lessstringentrequirements on CT: cost, dose reduction • Reduceproblems of not direct attenuationmeasurement in PET/MR • Open PET to new categories of patients (children, fœtus) Current state of the art for PET commercial devices: 500-250ps Current state of the art in the lab: 60-100ps (3-20mm crystals) Conventional PET 10ps TOFPET

  12. Where are we today for PET? Measured with FBK NUV-HD (25μm SPAD size, 4x4mm2 device size) 2x2mm2 crystal cross section, T=15°C NINO 30% 98ps 44% 58ps Breaking news HF electronics S. Gundacker et al, 2016 JINST 11 P08008

  13. The detectionchain Crystal SiPM electronics How to extract the best time estimator from the signal? Dt q2 g tkthpe = Dt + tk’ ph + ttransit + tSPTR + tTDC Scintillation process Transit time jitter Single photon time spread TDC conversion time Conversion depth Unwanted pulses 1 DCR, cross talk Afterpulses Randomdeletion 1 Absorption Self-absorption Randomdeletion 2 SiPM PDE Unwanted pulses 2 DCR

  14. Classification of scintillators Ideal Scintilllator

  15. Prompt photons to boost the timing resolution Cramer Rao calculations including photon transfer time spread (PTS) and light transfer efficiency (LTE) of a 2x2x3mm3LYSO:Ce ,Ca crystal, glue-coupled to a 4mm2 FBK-NUV HD SiPMs with 40um SPAD size S. Gundacker, CERN

  16. Possible sources of prompt photons ( < 1ns) Ce3+ Activator: 5d-4f Ca2+ & Mg2+ co-doping τr ~ 20 psτd ~ 16 ns Excitons/Bi-exciton stable at 300 K Hot Intraband Luminescence 0.1 - 10 ps High donor band semiconductors <1ns quenched at room temperature Cross Luminescence <1ns <300 nm – low LY Cerenkov τ ~ 5-10 ps

  17. LSO:Ce,Ca / BaF2 Eg hν Crossluminescence Courtesy of Hamamatsu 1400ph/MeV 600ps 220nm 50 50 s s Air coupling: LTE = 35% Glue coupling: LTE = 68% S. Gundacker, CERN

  18. Hot intraband luminescence • The smallenergy relaxation rate below the ionizationthresholdleads to: • a highdensity of optical and acoustic phonons • local heating, shockwave, transient absorption • a dynamic e population change from the top to the bottom of the conduction band • If the density of states is not uniform in the conduction band a competitioncantake place between phonon mediatednon-radiative relaxation and radiative relaxation between conduction sub-bands

  19. Hot intraband luminescence • Ultrafastemission≤ 10-12s • e-IBL: broadspectrum in visible range • H-IBL: NIR psectrum • Independant of temperature • Independant of defects • Absolute Quantum Yield Whn/Wphonon = 10-8/(10-11-10-12) ≈ 10-3 to 10-4 ph/eh pair • Higheryield if structures or dips in CB? Interesting to look at CeF3 Omelkovet.al., J. Lum., 176 (2016) 309–317

  20. Search for Candidates for Hot intraband luminescence • Search for materialswithsplitting of the conduction/valence band • Search for materialswith flat sub-bands for a perfectdelocalization of the electrons/holes • ExamplesOxy-halide compounds Ba4OF6 4.61g/cm3 GdOF 7.51g/cm3

  21. Cerenkov contribution LuAG:Pr 3,4 Cerenkov photons 0,28% LuAG:Ce LuAG:Pr, Ca S. Gundacker, E. Auffray, K. Pauwels, and P. Lecoq, Phys. Med. Biol. , vol. 61, pp. 2802–2837, 2016.

  22. Lowering Cerenkov threshold ? • Cerenkov threshold (101keV in LSO) can be strongly lowered (↘100’s eV) in specifically designed nanostructured metamaterials • Related more formally to the Smith Purcell effect • A kind of Cerenkov or transition radiation emission ➝ free electron lasers • Produce constructive interference of resonance transition radiation (plasmonic states) in photonic crystals • !! No velocity threshold !! Y. Yang et al., Nature Phys. Lett., 16 July 2018 I. Kaminer et al., Nature Comm., 13 June 2016

  23. Lowering Cerenkov threshold with hyperbolic metamaterials Isofrequency contour from dispersion formula: k Isofrequency contour from dispersion formula: k for isotropic dielectric material for anisotropic hyperbolic material + - + + Infinite density of photonic states in dw Finite density of photonic states in dw k+ kz kz k+ Fast e- kx kx Slow e- k- k- M. Silverinha, Nature Photonics, Vol. 11, May 2017

  24. Multi-exciton quantum confinement X XX XXX Gx Gxx= 4Gx Gxxx= 9Gx txxx = 69ps tx ~ 1ns txx = 196ps CdSe/ZnS Padilhaet.al., Nano Lett. 2013, 925-932

  25. GOS in 1D quantum confinedsystems • 372 nm laser or X-rays • LYSO • 200mm • 20mm CdSe film • deposition • Streak • Camera • LYSOplate 200mm thick • + CdSe/CdSnanoplate film 20mm thick J.Grim, I. Moreels ITT, Italy • Focalspot • optical • table 530nm 420nm 530nm R. Martinez Turtos et al., JINST_068P_06

  26. Limits of bulkmaterials Performance Limitation Courtesy of G. Bizzari, CranfieldUniversity

  27. Towardsheterostructures Performance Optimisation Courtesy of G. Bizzari, CranfieldUniversity

  28. Metamaterials From the Greek meta-, « metamaterials » means « beyondmaterials » (i.e. naturalmaterials) Prompt emission Quantum confined (bi)-excitons in nanocrystals High stoping power L(Y,G)SO, (La,Ce)Br3, BGO, CsI Light transport to SiPM Photonic crystals, photonic fibers

  29. Metapixels under study • Evaluation of the photodetectionefficiency in a samplinggeometrywith 2 active materials • Evaluation of the energyleakagefrom the dense to the fast material • CTR estimation from a full MC simulation of prompt and scintillation photons

  30. CdSe/LYSO plates Metapixel • 200mm thickLYSO plates • + 20mm effective thickness • CdSe/CdSnanoplatelet film • 3x3x3mm3 Fit on Rise & decay Time w/o peak LSO trise = 70ps S. Gundacker, R. Martinez-Turtos, CERN

  31. CdSe/BGO plates Metapixel • 200mm thick • Naked BGO plates • 2x2x3mm3 • 200mm thickBGO plates • + 20mm thick • CdSe/CdSnanoplatelet film • 2x2x3mm3 S. Gundacker, R. Martinez-Turtos, CERN

  32. Energy sharing studies BGO block 2x2x3mm3 NUV-HD SiPM 40mm SPAD (FBK) LYSO block 2x2x3mm3 NUV-HD SiPM 40mm SPAD (FBK) CTR with 57ps LSO pixel 121ps BC418&BC422 block 2x2x3mm3 NUV-HD SiPM 40mm SPAD (FBK) LYSO DTR=54ps BGO DTR=107ps BC422 DTR=25ps

  33. BC422/BGO plates Metapixel 125keV 300keV ⚫️ • 200mm thickBGO plates • + 200mm tBC422 • 2x2x3mm3 CTR with 57ps LSO pixel CTR with 57ps LSO pixel CTR with 57ps LSO pixel CTR with 57ps LSO pixel 110ps 87ps 70ps 87ps S. Gundacker, R. Martinez-Turtos, CERN

  34. Considerations for heterostructures design • Keep the density/photofraction close to the scintillator host (BGO, LSO) • Reach a reasonable balance between the standard/prompt photon light yield • Transport efficiently the light fromboth components • So far, simple and non optimised proof-of-concept designs BGO comb UCLA 200mm ZrO2 plates 100mm holes, 300mm spacing 3D printing CdZnS/CdS CERN

  35. Particularities of energy sharing in heterostructures • Timing resolutionisdifferent for all events • For a given fraction F of events sharing theirenergy, the number of eventsbenefitingfrom a CTR improvementis: F(2-F) > F • 2/3 eventsshareenergy in 100mmBGO/100mmBC422 • 89% eventswill have a CTR betterthanbulk BGO • CTR ismuchlessdependant on detectionthreshold

  36. Conclusion- Potential of metamaterials • By making use of light-management strategies, Nanophotonicsprivides a playground to make the unimaginable come closer. • This opens the way to transformation optics (a kind of extrapolation of Maxwell’s equations invariance under Lorenz transformation), allowing to envision a distortion of real space that results in a desired functionality: • Ultrafast emission • Enhanced fluorescence yield through plasmonic resonances • Redirect light into preferred directions • Electromagnetic cloaks • Improve thermal dissipation • In our case, this is a fertile field for developing innovative solutions for ultrafast • Light production • Light transport • Light photoconversion

  37. The best metapixelrequires the best SiPM

  38. New SiPM concept The Quantum Silicon Detector

  39. The 10ps challenge: • a spur on the development of fast timing • an opportunity to get together • an incentive to raise funding • a way to shed light on nuclear instrumentation for medical imaging • One unique challenge launched for 5 to 10 years and operated by an international organisation with rules issued by the community based on the measurement of CTR combined to sensitivity • Several milestones and prices: • 3 years after the launch of the challenge: 1M€ expected for the Flash Gordon prices for the realisation of 3 important milestones • until the end of the challenge: 1M€ expected for the Leonard McCoy price for the first team meeting successfully the specifications of the challenge

  40. Conclusion New, intelligent Multifunctional sensors Disruptive technologies Nano-photonics New perspectives “Impossible” is not a French word Napoléon

  41. Many thanks to

More Related