1 / 39

BG study in PAT CMSSW_3_5_7

Event Selection - Electron p T > 20 GeV/c - Electron Isolation < 0.1 - Standard Electron Identification  - Electron abs(eta) < 2.5 - Missing Transverse Energy > 20 GeV - At less one jet is b (>2.03). M(jj) Reconstruction - Jet p T > 30 GeV/c

Télécharger la présentation

BG study in PAT CMSSW_3_5_7

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Event Selection - Electron pT > 20 GeV/c - Electron Isolation < 0.1 - Standard Electron Identification  - Electron abs(eta) < 2.5 - Missing Transverse Energy > 20 GeV - At less one jet is b (>2.03) M(jj) Reconstruction - Jet pT > 30 GeV/c - HighEfficenecy b tag < 2.03 - abs(eta) <3 - ΔR(jj) > 0.5 1 BG study in PAT CMSSW_3_5_7 All of these using this event selection “Old cuts” *With L2L3 energy correction Data set: /TTbar/Spring10-START3X_V26_S09-v1/AODSIM Data set: /QCD4Jets-alpgen/Spring10-START3X_V26_S09-v1/AODSIM Data set: /WJets-madgraph/Spring10-START3X_V26_S09-v1/AODSIM Data set: /ZJets-madgraph/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt0to15/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt15to20/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt20to30/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set:/ZeeJet_Pt30to50/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt50to80/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt80to120/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt120to170/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt170to230/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt230to300/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO Data set: /ZeeJet_Pt300toInf/Spring10-START3X_V26_S09-v1/GEN-SIM-RECO

  2. TTBar Same Events Mixed Events 2

  3. TTBar Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 3

  4. TTBar After subtraction Before subtraction 4 Zoom-in

  5. QCD4Jets Same Events Mixed Events 5

  6. QCD4Jets Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 6

  7. QCD4Jets After subtraction Before subtraction 7 Zoom-in

  8. WJets Same Events Mixed Events 8

  9. WJets Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 9

  10. WJets After subtraction Before subtraction 10 Zoom-in

  11. ZJets Same Events Mixed Events 11

  12. ZJets Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 12

  13. ZJets After subtraction Before subtraction 13 Zoom-in

  14. ZeeJet_Pt0to15 14 No event passed the cuts

  15. ZeeJet_Pt15to20 15 Cannot do data driven method because on event in region 300 to 500 GeV

  16. ZeeJet_Pt20to30 Same Events Mixed Events 16

  17. ZeeJet_Pt20to30 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 17

  18. ZeeJet_Pt20to30 After subtraction Before subtraction 18 Zoom-in

  19. ZeeJet_Pt30to50 Same Events Mixed Events 19

  20. ZeeJet_Pt30to50 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 20

  21. ZeeJet_Pt30to50 After subtraction Before subtraction 21 Zoom-in

  22. ZeeJet_Pt50to80 Same Events Mixed Events 22

  23. ZeeJet_Pt50to80 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 23

  24. ZeeJet_Pt50to80 After subtraction Before subtraction 24 Zoom-in

  25. ZeeJet_Pt80to120 Same Events Mixed Events 25

  26. ZeeJet_Pt80to120 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 26

  27. ZeeJet_Pt80to120 After subtraction Before subtraction 27 Zoom-in

  28. ZeeJet_Pt120to170 Same Events Mixed Events 28

  29. ZeeJet_Pt120to170 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 29

  30. ZeeJet_Pt120to170 After subtraction Before subtraction 30 Zoom-in

  31. ZeeJet_Pt170to230 Same Events Mixed Events 31

  32. ZeeJet_Pt170to230 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 32

  33. ZeeJet_Pt170to230 After subtraction Before subtraction 33 Zoom-in

  34. ZeeJet_Pt230to300 Same Events Mixed Events 34

  35. ZeeJet_Pt230to300 Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 35

  36. ZeeJet_Pt230to300 After subtraction Before subtraction 36 Zoom-in

  37. ZeeJet_Pt300toInf Same Events Mixed Events 37

  38. ZeeJet_Pt300toInf Same event 300-500 GeV/c2 Mixed event after normalization Log Scale Normalization Region 38

  39. ZeeJet_Pt300toInf After subtraction Before subtraction 39 Zoom-in

More Related