油纸绝缘电力电缆 的绝缘

油纸绝缘电力电缆 的绝缘. 11 供电 4 班 - 熊小莉 -110217438. · 油纸绝缘. 粘性浸渍绝缘型(统包型、分相屏蔽型),不滴流浸渍纸绝缘型( 统包型、分相屏蔽型 ),有油压、油浸渍纸绝缘型(自容式充油电缆和钢管充油电缆 ) 都是油纸绝缘类型 。. ·· 纸绝缘 电缆. 纸绝缘电缆分为黏性浸渍电缆、充油电缆和充气电缆三种。 黏 性浸渍绝 缘在生产过程中、特别是运行过程中,不可避免会在绝缘中形成气隙,因而一般只能用于交流 35kv 及以下。

laith-nunez
Télécharger la présentation

油纸绝缘电力电缆 的绝缘

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 油纸绝缘电力电缆的绝缘 11供电4班-熊小莉-110217438

  2. ·油纸绝缘 粘性浸渍绝缘型(统包型、分相屏蔽型),不滴流浸渍纸绝缘型(统包型、分相屏蔽型),有油压、油浸渍纸绝缘型(自容式充油电缆和钢管充油电缆)都是油纸绝缘类型。

  3. ··纸绝缘电缆 纸绝缘电缆分为黏性浸渍电缆、充油电缆和充气电缆三种。 黏性浸渍绝缘在生产过程中、特别是运行过程中,不可避免会在绝缘中形成气隙,因而一般只能用于交流35kv及以下。 常用的充油电缆有钢管充油式或自容式两种型式。充气电缆的附属设备等较充油电缆简单,而且没有液体静压力,特别适宜于用作高落差的高压电缆线路。

  4. ··电缆接头盒 电缆的两端都应有终端接头盒,通过它与变压器或架空线相连接。户外终端接头盒都应有密封的瓷套(或环氧树脂套等)以防潮气进入。 在电缆终端处,在金属护层终端处附近不仅电场异常集中,而且有很强的轴向分量。为提高放电电压,必须设法改善电场分布。

  5. ··油浸纸绝缘电缆的直流耐压实验 在进行直流耐压试验时测泄漏电流,实际上和用兆欧表测电缆绝缘电阻的道理是完全相同的。但由于直流耐压试验时施加电压和使用的仪表准确度都高于兆欧表,而且可以在加压过程中观察泄漏电流的变化,所以泄漏电流试验比测量绝缘电阻更能有效地发现绝缘缺陷。 为使所测得的泄漏电流反映电缆绝缘的真实状况,应采取措施消除外来因素对泄漏电流的影响。如果测得的泄漏电流数值不稳定,泄漏电流随时间延长而上升,或随试验电压增加而急剧上升,必须查明原因。