1 / 24

CONSORCIO IEH GRUCON PROFINVEST

EMPRESA IBAGUEREÑA DE ACUEDUCTO Y ALCANTARILLADO IBAL. PRESENTACIÓN AVANCE DEL CONTRATO IBAL 0072 DE 2012 REVISIÓN Y ACTUALIZACIÓN DE LOS DISEÑOS DEL ACUEDUCTO COMPLEMENTARIO DE LA CIUDAD DE IBAGUÉ ABRIL DE 2013. CONSORCIO IEH GRUCON PROFINVEST. DATOS DEL CONTRATO.

laura-bass
Télécharger la présentation

CONSORCIO IEH GRUCON PROFINVEST

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMPRESA IBAGUEREÑA DE ACUEDUCTO Y ALCANTARILLADO IBAL PRESENTACIÓN AVANCE DEL CONTRATO IBAL 0072 DE 2012 REVISIÓN Y ACTUALIZACIÓN DE LOS DISEÑOS DEL ACUEDUCTO COMPLEMENTARIO DE LA CIUDAD DE IBAGUÉ ABRIL DE 2013 CONSORCIO IEH GRUCON PROFINVEST

  2. DATOSDEL CONTRATO • CONTRATISTA: CONSORCIO IEH GRUCON - PROFINVEST • OBJETO: REVISION Y ACTUALIZACION DE LOS DISEÑOS DE ACUEDUCTO COMPLEMENTARIO DE LA CIUDAD DE IBAGUE. • PLAZO DE EJECUCION: 6 MESES • FECHA DE SUSCRIPCION: 31 DE DICIEMBRE DE 2012 • FECHA INICIO: 22 DE ENERO DE 2013 • FECHA DE TERMINACION: 22 DE JULIO DE 2013 • VALOR: 767.751.800 INCLUIDO IVA • FORMA DE PAGO: ANTICIPO 30% (AUN NO SE HA RECIBIDO EL PAGO) • PRIMER PAGO 70% • PAGO A TERMINACION 20% • LIQUIDACION 10% CONSORCIO IEH GRUCON PROFINVEST

  3. ALCANCE DEL PROYECTO • REDISEÑO DE LA PLANTA DE TRATAMIENTO DE BOQUERÓN. • REVISIÓN Y ACTUALIZACIÓN DE LOS DISEÑOS DE LOS TANQUES DE ALMACENAMIENTO TANQUE SUR Y TANQUE BOQUERÓN. • DISEÑO DE LOS TANQUES DE ALMACENAMIENTO DENOMINADOS FISCALÍA (JORDÁN) Y AMPLIACIÓN TANQUE ALSACIA. INTERCONEXIÓN TANQUE SUR – TANQUE FISCALÍA, INTERCONEXIÓN TANQUE LA 29 – TANQUE LA FISCALÍA, INTERCONEXIÓN TANQUE AMBALÁ – TANQUE NUEVO LA ALSACIA. • REVISIÓN Y ACTUALIZACIÓN DE LOS DISEÑOS DE LA CONDUCCIÓN BOCATOMA COCORA - PTAP BOQUERÓN K4+700 A K12+700. • REVISIÓN Y ACTUALIZACIÓN DE LOS DISEÑOS DE LAS CONDUCCIONES: PTAP BOQUERÓN - TANQUE SUR, PTAP BOQUERÓN – TANQUE BOQUERÓN Y PTAP BOQUERÓN – TANQUE CIUDAD LA POLA. CONSORCIO IEH GRUCON PROFINVEST

  4. ALCANCE DEL PROYECTO CONSORCIO IEH GRUCON PROFINVEST

  5. ESTUDIO DE POBLACIÓN Y DEMANDA • SE ACTUALIZÓ EL ESTUDIO DE POBLACIÓN Y DEMANDA A LAS CONDICIONES PRESENTES DE LA CIUDAD DE IBAGUÉ Y A LOS REQUERIMIENTOS DE LA NORMATIVIDAD VIGENTE RAS 2000. • LA POBLACIÓN ACTUAL ESTIMADA ES APROXIMADAMENTE 528,000 HAB. • LA PROYECCIÓN DE LOS ESTUDIOS ANTERIORES FUE MUY SUPERIOR AL CRECIMIENTO REAL DE LA POBLACIÓN. • SE SELECCIONÓ EL MÉTODO ARITMÉTICO PARA LA PROYECCIÓN DE POBLACIÓN DADO QUE LAS TASAS DE CRECIMIENTO ANUAL VAN DISMINUYENDO EN EL TIEMPO, SIGUIENDO LA TENDENCIA DEL COMPORTAMIENTO ACTUAL DE LA CIUDAD. • LA POBLACIÓN RESIDENTE PROYECTADA AL FINAL DEL PERIODO DE DISEÑO ESTABLECIDO EN EL 2043 ES DE 803,413 HAB. CONSORCIO IEH GRUCON PROFINVEST

  6. ESTUDIO DE POBLACIÓN Y DEMANDA CONSORCIO IEH GRUCON PROFINVEST CONSORCIO IEH GRUCON PROFINVEST

  7. ESTUDIO DE POBLACIÓN Y DEMANDA PROYECCIÓN SELECCIONADA CONSORCIO IEH GRUCON PROFINVEST

  8. ESTUDIO DE POBLACIÓN Y DEMANDA • SE CALCULÓ LA DOTACIÓN NETA ACTUAL RESIDENCIAL EN 122.33 l/hab-día. • SE CALCULÓ LA DOTACIÓN NETA POR OTROS USUARIOS (C+I+O) EN 32.48 l/hab-día. • SE ESTIMÓ EL ÍNDICE DE AGUA NO CONTABILIZADA IANC ACTUAL EN 43.38%. • LA COBERTURA ACTUAL ES DEL 87%Y SE PROYECTÓ UNA COBERTURA DEL 100% EN UN TÉRMINO DE 10 AÑOS. • SE PROYECTARON DEMANDAS DE AGUA DE ACUERDO CON LO ESTABLECIDO EN EL RAS 2000 PARA LA POBLACIÓN TOTAL DE IBAGUÉ. • SE RECOMENDO LA IMPLEMENTACIÓN DE UN PROGRAMA DE CONTROL Y REDUCCIÓN DE LAS PÉRDIDAS DE AGUA, PARA QUE EN UN PLAZO DE 10 AÑOS EL IANC DEL SISTEMA DE IBAGUÉ SEA DEL ORDEN DEL 25% EXIGIDO POR EL RAS. CONSORCIO IEH GRUCON PROFINVEST

  9. ESTUDIO DE POBLACIÓN Y DEMANDA CONSORCIO IEH GRUCON PROFINVEST

  10. ESTUDIO DE POBLACIÓN Y DEMANDA • SE CALCULÓ EL CAUDAL MÁXIMO DIARIO AL AÑO 2043 EN 2,759 l/S. • LA CAPACIDAD ACTUAL DE LAS PLANTAS DE TRATAMIENTO ES DE 2,320 l/s. • DE ACUERDO CON LOS CALCULOS SE TIENE QUE LA CAPACIDAD DE TRATAMIENTO ACTUAL DEL SISTEMA ES SUFICIENTE HASTA EL AÑO 2031 Y EL DÉFICIT AL FINAL DEL PERIODO DE DISEÑO (2043) ES DEL ORDEN DE 439 l/s. • TENIENDO EN CUENTA QUE EN LA PLANTA 1 DE LA POLA AÚN SE ENCUENTRA PENDIENTE POR CONSTRUIR UN CUARTO TREN DE TRATAMIENTO CON EL CUAL LA CAPACIDAD INSTALADA SE PODRÍA AUMENTAR EN MÁS DE 500 LPS, CON UNA INVERSIÓN CONSIDERABLEMENTE MENOR A LA CONSTRUCCIÓN DE UNA NUEVA PTAP EN BOQUERÓN, ESTA CONSULTORÍA RECOMIENDA NO LLEVAR A CABO LA CONSTRUCCIÓN EN EL CORTO O MEDIANO PLAZO DE LA PTAP DE EL BOQUERÓN. • ESTA RECOMENDACIÓN IMPLICA QUE SE REQUIERE UN BOMBEO DE 265 l/s APROXIMADAMENTE PARA ABASTECER EL TANQUE BOQUERON DESDE EL TANQUE SUR CONSORCIO IEH GRUCON PROFINVEST

  11. ESTUDIO DE POBLACIÓN Y DEMANDA • SE REALIZÓ EL ESTUDIO DE URBANISMO PARA ESTABLECER LAS DEMANDAS POR DISTRITO. CONDICIÓN ACTUAL CONSORCIO IEH GRUCON PROFINVEST

  12. ESTUDIO DE POBLACIÓN Y DEMANDA • SE CONTEMPLARON LAS ÁREAS DE EXPANCIÓN DEL POT. ÁREAS DE EXPANSIÓN CONSORCIO IEH GRUCON PROFINVEST

  13. ESTUDIO DE POBLACIÓN Y DEMANDA • SE CONFORMARON LOS DISTRITOS DE SERVICIO PARA EL PERIODO DE DISEÑO. CONDICIÓN FUTURA CONSORCIO IEH GRUCON PROFINVEST

  14. ESTUDIO DE POBLACIÓN Y DEMANDA • SE CALCULÓ LA POBLACIÓN ACTUAL POR DISTRITO. • SE CALCULÓ LA CAPACIDAD MÁXIMA DE POBLACIÓN DE CADA UNO. • SE REALIZÓ LA PROYECCIÓN DE POBLACIÓN POR DISTRITOS. • SE DETERMINARON LOS DISTRITOS QUE ALCANZAN LA SATURACIÓN Y SU CONSECUENTE REDISTRIBUCION. • SE CALCULARON FINALMENTE LAS DEMANDAS MAXIMAS A NIVEL DE DISTRITO PARA ESTABLECER LOS REQUERIMIENTOS DE ALMACENAMIENTO EN CADA UNO. CONSORCIO IEH GRUCON PROFINVEST

  15. ANÁLISIS DE CAPACIDAD DE LOS TANQUES • TENIENDO EN CUENTA LA POBLACIÓN FINAL PROYECTADA PARA CADA DISTRITO, SE CALCULARON LOS VOLUMENES DE ALMACENAMIENTO Y REGULACIÓN REQUERIDOS DE ACUERDO CON LA NORMATIVIDAD VIGENTE. • SE COMPARARON LOS VOLÚMENES REQUERIDOS A FUTURO CON LA CAPACIDAD ACTUAL DE LOS TANQUES EXISTENTES Y SE ESTABLECIERON LOS DÉFICITS Y LAS NECESIDADES EN CADA DISTRITO. • SE REALIZÓ EL DIMENSIONAMIENTO DE LOS VOLÚMENES PARA LOS TANQUES INCLUIDOS EN ESTE CONTRATO QUE CORRESPONDEN AL TANQUE SUR, TANQUE BOQUERÓN, TANQUE ALSACIA Y TANQUE LA FISCALÍA. • TANQUE SUR: 800 m3 PARA ALMACENAMIENTO DEL DISTRITO 3. • 1,200 m3 PARA ALIMENTACIÓN POR BOMBEO DEL TANQUE BOQUERÓN. • TOTAL = 2,000 m3 CONSORCIO IEH GRUCON PROFINVEST

  16. ANÁLISIS DE CAPACIDAD DE LOS TANQUES TANQUE ALSACIA: 1,500 m3 PARA REGULACIÓN DEL DISTRITO 7. TOTAL = 1,500 m3. TANQUE FISCALÍA: 6,100 m3 ALMACENAMIENTO REQUERIDO DISTRITO 11. 2,200 m3 ALMACENAMIENTO PARA SUPLIR DÉFICIT DEL DISTRITO 8. 1,700 m3 ALMACENAMIENTO PARA SUPLIR DÉFICIT DEL DISTRITO 9. TOTAL = 10,000 m3. TANQUE BOQUERÓN: 4,000 m3 PARA REGULACIÓN DEL DISTRITO 7. TOTAL = 4,000 m3. CONSORCIO IEH GRUCON PROFINVEST

  17. ANÁLISIS HIDRAÚLICO DE TUBERÍAS DE INTERCONEXIÓN DE TANQUES • TENIENDO EN CUENTA LA LOCALIZACIÓN DE LOS LOTES PREVIAMENTE DEFINIDOS PARA LOS TANQUES PROYECTADOS SE REALIZÓ LA EVALUACIÓN HIDRÁULICA DE LAS TUBERÍAS DE INTERCONEXIÓN . • INTERCONEXIÓN TANQUE SUR – TANQUE FISCALÍA: • SE DETERMINÓ UN CAUDAL APROXIMADO DE 480 l/s Y UN DIÁMETRO DE 20” EN TUBERÍA FLEXIBLE. • INTERCONEXIÓN TANQUE AMBALÁ – TANQUE NUEVO ALSACIA: • SE DETERMINÓ UN CAUDAL APROXIMADO DE 129 l/s Y UN DIÁMETRO DE 10” EN TUBERÍA FLEXIBLE. CONSORCIO IEH GRUCON PROFINVEST

  18. ANÁLISIS HIDRAÚLICO DE TUBERÍAS DE INTERCONEXIÓN DE TANQUES INTERCONEXIÓN TANQUE SUR – TANQUE BOQUERÓN: SE DETERMINÓ UN CAUDAL DE BOMBEO APROXIMADO DE 262 l/s Y UN DIÁMETRO DE 14” EN TUBERÍA METÁLICA. INTERCONEXIÓN TANQUE CIUDAD LA POLA – TANQUE SUR: SE DETERMINÓ UN CAUDAL APROXIMADO DE 694 l/s Y UN DIÁMETRO DE 34” EN TUBERÍA FLEXIBLE. CONSORCIO IEH GRUCON PROFINVEST

  19. TRABAJOS DE CAMPO ADELANTADOS • SE ADELANTARON LEVANTAMIENTOS TOPOGRAFÍCOS DE LOS PREDIOS DEFINIDOS PREVIO AL INICIO DEL CONTRATO PARA LA PROYECCIÓN DE LOS SIGUIENTES TANQUES DE ALMACENAMIENTO: • TANQUE ALSACIA. • TANQUE FISCALÍA. • TANQUE SUR. • TANQUE BOQUERÓN. • SE ADELANTARON LEVANTAMIENTOS TOPOGRAFÍCOS PARA LA PROYECCIÓN DE LAS SIGUIENTES TUBERÍAS DE INTERCONEXIÓN: • TANQUE CIUDAD LA POLA – TANQUE SUR. • TANQUE SUR – TANQUE BOQUERÓN. CONSORCIO IEH GRUCON PROFINVEST

  20. TRABAJOS DE CAMPO ADELANTADOS • TANQUE SUR – TANQUE FISCALÍA. • TANQUE AMBALÁ – TANQUE ALSACIA. • LEVANTAMIENTO TOPOGRÁFICO DE LA LÍNEA DE ADUCCIÓN ENTRE EL K4+700 HASTA LA PLANTA DE TRATAMIENTO LA POLA. • SE ADELANTARON VISITAS DE VERIFICACIÓN GEOTÉCNICA EN LOS SIGUIENTES PUNTOS: • LOTE DESTINADO PARA EL TANQUE LA FISCALÍA: • INICIALMENTE SE ESTABLECE UN RIESGO ALTO EN LA PROYECCIÓN DEL TANQUE EN EL ESPACIO DESTINADO POR LOS URBANIZADORES. SE ESTÁ EVALUANDO GEOTÉCNICAMENTE UNA ALTERNATIVA PARA DESPLAZAR EL TANQUE Y REDUCIR SU DIÁMETRO INCREMENTANDO SU ALTURA. CONSORCIO IEH GRUCON PROFINVEST

  21. TRABAJOS DE CAMPO ADELANTADOS • LOTE DESTINADO PARA EL TANQUE LA ALSACIA: • INICIALMENTE SE ESTABLECE QUE NO ES CONVENIENTE LA PROYECCIÓN DEL TANQUE EN EL ESPACIO DESTINADO. SE ESTÁ EVALUANDO GEOTÉCNICAMENTE UNA ALTERNATIVA PARA ESTABLECER QUE CAPACIDAD MÁXIMA SE PODRÍA CONSTRUIR EN ESTE LOTE. • ADICIONALMENTE, SE ESTÁN EVALUANDO PRELIMINARMENTE LOTES PARA UNA LA POSIBLE RELOCALIZACIÓN DEL TANQUE QUE CUMPLAN LAS CONDICIONES HIDRAULICAS REQUERIDAS. CONSORCIO IEH GRUCON PROFINVEST

  22. EVALUACIÓN HIDRÁULICA DESARENADORES SE REALIZÓ LA EVALUACIÓN HIDRÁULICA DE LOS DESARENADORES CONSTRUIDOS EN EL SITIO DE LA CAPTACIÓN SOBRE EL RÍO COCORA. SE VERIFICO SU ADECUADO FUNCIONAMIENTO HIDRAULICO PARA UN CAUDAL DE HASTA 1000 LITROS CON UNA ALTA EFICIENCIA, SIENDO NECESARIO UNICAMENTE OPTIMIZAR LOS BAFLES DE ENTRADA PARA MEJORAR LAS LINEAS DE FLUJO. SE ESTÁ ADELANTANDO EL ESQUEMA DE OPTIMIZACIÓN. CONSORCIO IEH GRUCON PROFINVEST

  23. INCONVENIENTES PRESENTADOS PARA EL DISEÑO DE LOS TANQUES FISCALÍA Y ALSACIA, SE TIENE AÚN INCERTIDUMBRE EN LA LOCALIZACIÓN DEFINITIVA DE LOS TANQUES, DADAS LAS CONDICIONES DE LOS LOTES INICIALMENTE ESTABLECIDOS. TANQUE FISCALÍA: EL LOTE INICIALMENTE DEFINIDO POR EL IBAL HACE PARTE DE UN DESARROLLO URBANISTICO ADELANTADO POR LOS PROPIETARIOS DEL PREDIO, QUIENES DEJARON UN ESPACIO LIBRE PARA LA LOCALIZACION DEL TANQUE LIMITADO EN EL SUR POR UN TALUD DE ALTA PENDIENTE QUE OBLIGA A UN ANALISIS GEOTECNICO Y GEOLOGICO DETALLADO SOBRE LOS RIESGOS DE LA UBICACIÓN DEL TANQUE EN ESTA ZONA. TANQUE ALSACIA: EN EL LOTE PREVISTO YA EXISTE LA PRIMERA ETAPA DEL TANQUE ALSACIA Y ESTA LOCALIZADO A MEDIA LADERA, SE TIENE RESTRICCIÓN DEL ÁREA DISPONIBLE SIN INTERVENCIONES DEL TALUD. CONSORCIO IEH GRUCON PROFINVEST

  24. TRABAJOS EN EJECUCIÓN ESQUEMA DE OPTIMIZACIÓN DESARENADORES. DISEÑO DE DETALLE DEL TANQUE SUR Y DEL TANQUE BOQUERÓN. EVALUACIÓN DE LOS LOTES PARA LOS TANQUES FISCALÍA Y ALSACIA PARA PROCEDER AL DISEÑO DE DETALLE TANTO DE LOS TANQUES COMO DE LAS LINEAS DE INTERCONEXION. INICIO DEL DISEÑO DE DETALLE PARA LAS REDES DE ADUCCIÓN, INTERCONEXIÓN SUR – BOQUERÓN, INTERCONEXIÓN LA POLA – SUR. CONSORCIO IEH GRUCON PROFINVEST

More Related