1 / 7

RadTherm Analysis EcoStud Z Furring versus Steel Stud (Summer)

RadTherm Analysis EcoStud Z Furring versus Steel Stud (Summer). RadTherm Model Setup. 130 W/m 2. Wall Top View. (Solar Load for a ~90F day full sun on wall). Concrete. Polystyrene Foam Board (1.5 inch). Stud 25 gauge Steel Versus 0.09inch EcoStud (16 inches on center).

lecea
Télécharger la présentation

RadTherm Analysis EcoStud Z Furring versus Steel Stud (Summer)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RadTherm AnalysisEcoStud Z FurringversusSteel Stud(Summer)

  2. RadTherm Model Setup 130 W/m2 Wall Top View (Solar Load for a ~90F day full sun on wall) Concrete Polystyrene Foam Board (1.5 inch) Stud 25 gauge Steel Versus 0.09inch EcoStud (16 inches on center) Gypsum Board (0.5 inch) FOUO UNCLASSIFIED

  3. RadTherm Model Setup Polystyrene Foam Board (1.5 inch) Concrete (10 inch) 130 W/m2 Gypsum Board (0.5 inch) Wall Side View FOUO UNCLASSIFIED

  4. Concrete Results Interior Surface Temperatures of Gypsum EcoStud Steel Stud FOUO UNCLASSIFIED

  5. Concrete Results Interior Surface Temperatures of Foam and Stud EcoStud Steel Stud FOUO UNCLASSIFIED

  6. Concrete Results Exterior Concrete Surface Temperatures EcoStud Steel Stud FOUO UNCLASSIFIED

  7. Conclusion • Steel studs pull heat away from the exterior concrete wall. The heat conducts along the stud and through to the interior wall of the building. • EcoStuds are considerably less conductive and minimize the heat that is transferred from the exterior environment into the building. This results in less energy requirements to maintain a comfortable air temperature within the building. FOUO UNCLASSIFIED

More Related