An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Section F Alternate Technologies

  2. Bio-medical waste and technology • Technology is only a fraction of the solution. • Major components of waste management are: • Segregation of waste • Waste minimisation • Reducing use of hazardous substances or processes • Waste Audit F1

  3. Treatment technologies Treatment technology for bio-medical waste should: • Disinfect waste • Make waste non-reusable • Be environmentally safe • Should consider worker safety F2

  4. Approved treatment methods • Autoclave • Chemical disinfection • Hydroclave • Microwave • Incineration • Any other technology after CPCB approval F3

  5. Technologies for bio-medical waste treatment • Thermal processes • Low heat • Medium heat • High heat • Chemical processes • Irradiative processes • Biological processes F4

  6. Biological indicators Suspensions of resistant endospores are used as biological indicators for microbial inactivation: • Bacillus stearothermophilus: thermal • Bacillus subtilis: chemical • Bacillus pumilus: irradiation F5

  7. Autoclaves • Saturated steam acts as the disinfecting agent • Pressure, temperature, time combinations • for gravity flow 121oC, 15psi, 60’/135oC, 31psi,45’/149oC,52psi, 30’ • for pre- vacuum type (121oC, 15psi, 45’/135oC, 31psi, 30`) F6

  8. Types of autoclaves Air is an effective insulator, thus complete disinfection demands removal of air from the chamber. Two methods of removing air are: • Gravity displacement • Pre-vacuum F7

  9. Components of an autoclave Major components • A metal chamber that can withstand high pressure • A steam jacket surrounding the chamber • A steam generator • A capillary thermometer and 2 pressure gauges to monitor temperatures and pressures respectively • Recording mechanism F8

  10. Stages in autoclave operation • Pre-heating • Loading of waste with an indicator • Air evacuation • Steam treatment • Steam discharge • Unloading • Mechanical treatment F9

  11. Types of waste allowed/ disallowed Type of waste allowed category (3,4,6,7): • Microbiological and biotechnological waste • Sharps, soiled waste, solid waste Not to be treated: • Volatile and semi-volatile organic compounds • Chemotherapeutic wastes, mercury and other hazardous chemical waste • Radiological waste, Sealed heat resistant containers • Huge and bulky bedding material Poorly segregated waste can lead to emission of alcohols, phenols, aldehydes, mercury and other toxic contaminants F10

  12. Advantages • Proven technology, with disinfection parameters well established • Minimal emissions (with properly segregated waste) • Relatively lower capital costs • Automated systems F11

  13. Disadvantages • Waste recognisable after treatment • No volume reduction (till a shredder is attached) • Odours • Emissions (with unsegregated waste) • Process gives wet waste, if not subjected to drying • Barriers to direct steam exchange may compromise efficiency. F12

  14. Points to ponder • Segregated waste is a must • Air evacuation is necessary • Place bags in multi-load trays • Proper ventilation to avoid odors • Thermocouples and pressure gauges should be checked frequently F13

  15. Hydroclave • Hydroclave is steam treatment with fragmentation and drying of waste • It has a double walled chamber with an agitator inside • Steam is injected into this wall (jacket) and waste is loaded in the inner chamber • The agitator fragments and turns waste F14

  16. Hydroclave: treatment mechanism • The moisture in the waste turns to steam and exerts pressure on the inner walls. If this pressure is not sufficient, additional steam may be injected inside. • Cycle runs at 132oC for 15’/ 121oC for 30’ • Finally the steam is vented through a condenser while maintaining heat input, causing the waste to dry • Steam is shut off, discharge door is opened and agitator runs in reverse rotation to place the waste on a conveyor belt/ container. F15

  17. Hydroclave • Advantages • Shredded, dry waste • Internal mixing improves transfer of heat • Disadvantages • Clogging of agitator blades with waste • Mixed shredded waste makes recycling difficult F16

  18. Microwave: action mechanism • Disinfection by moist heat and steam generated by microwave energy • Magnetrons convert high voltage electrical energy into microwave energy • The microwaves create an electromagnetic field • Water and other molecules in waste try to align in the field and in the process they vibrate • Vibration of the molecules produces heat F17

  19. Microwave: action mechanism Microwave kills by two mechanisms: • By heat energy from the steam generated • Changing the biological molecular structure of proteins F18

  20. Microwave: operating parameters • Microwaves are high frequency (2450+50mhz) radio waves capable of creating electromagnetic field • Temperatures reached are around 97-100oC. In some new systems, steam under pressure is passed, to achieve temperatures>135oC. • Cycle time is around 25’ • Typically, around 2-6 magnetrons are used with an output of about 1.2KW each F19

  21. Stages in microwave operations • Waste loading • Steam injection in the hopper • Internal shredding • Microwave treatment • Disinfection cycle • Optional secondary shredding • Discharge Category of waste that can be and cannot be treated is similar to the autoclave. Emission parameters are also similar F20

  22. Advantages and disadvantages Advantages • In use for more than a decade • Minimal emissions if no hazardous waste fed • Automated system • No liquid effluent Disadvantages • Relatively high capital cost • Toxic emissions if hazardous waste fed • Any large metal item can damage shredders • Odour problems • Probability of microwave energy leakage F21

  23. Points to ponder • Properly segregated waste is a must. It becomes necessary to ensure: • absence of large metal blocks • absence of hazardous or radiological waste: • Workers to be trained for monitoring leakage of microwave energy and handle it F22

  24. Other thermal technologies • Low heat (dry) technologies (<350oF) • high velocity heated air • Medium heat (350oF-700oF) • reverse polymerization or thermal depolymerisation • High heat technologies (1,000oF-15,000oF) • pyrolysis Medium and high heat technologies also produce dioxins and furans and other toxic pollutants, require pollution control devices, and are fairly expensive. F23

  25. Chemical methods • (NaOH/ KOH: For treatment of pathological and cytotoxic waste): • Sodium hypochlorite • Glutarladehyde • Peracetic acid • Ozone gas • Calcium oxide • Sodium hydroxide: alkaline hydrolysis F24

  26. Evolving technologies Irradiation (ionising radiation): • X rays/gamma rays • Electron beam Biological: • Enzymes • Composting, vermiculture F25

  27. Choosing an alternate technology • Throughput capacity • Types of waste treated/not suited • Microbial inactivation efficiency • Environmental emissions and water residues • Regulatory acceptance • Space requirements • Utility and other installation requirements F26

  28. Choosing an alternate technology • Reduction of waste volume and mass • Occupational safety and health • Noise and odour • Automation • Reliability • Manufacturer background • Cost • Recurring cost and maintenance • After sales service • Level of operator training, other manpower requirement F27

  29. Centralised facilities Guidelines on common facilities • Treatment facilities: 90% non-burn, 10% burn • Limits incineration to Categories 1&2 • At least 1 Km from residential areas. Acceptable in industrial area • One operator allowed to cater upto 10,000 beds, situated within 150 km radius • Segregation is the role of generator; operator can report mixing of waste to the prescribed authority F28