1 / 77

WHO IS AN ENGINEER?

Design of RCC structures Detailing of Reinforcement (IS456-2000, IS13920) Pradip Paudel (M.Sc. in Structural Engineering). WHO IS AN ENGINEER?. The great liability of the engineer …compared to men of other professions……is that his works are out in the open where all can see them.

lmcmahon
Télécharger la présentation

WHO IS AN ENGINEER?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design of RCC structuresDetailing of Reinforcement(IS456-2000, IS13920)Pradip Paudel(M.Sc. in Structural Engineering)

  2. WHO IS AN ENGINEER? The great liability of the engineer …compared to men of other professions……is that his works are out in the open where all can see them. He cannot bury his mistakes in the grave like the DOCTORS. He cannot, like the ARCHITECT, cover his figures with trees A design engineer’s responsibility should include assuring the structural safety of the design, details, checking shop drawing. Detailing is as important as design

  3. Requirements of Good Detailing Should be simple for fabrication and placing Check spacing for crack control – maximum spacing Minimum spacing for concrete placing Check for splicing requirements and development length Special care for section of varying depth and sloped slabs Care for corner joints, beam column junction, openings etc.

  4. Cont.… • Detailing for gravity loads is different from the lateral loads specially for the SEISMIC FORCES. • Apart from the detailing for the above there is a different detailing required for the rehabilitation and strengthening of damaged structures. • Detailing codes SP16 and IS456-2000 • EQ code is 13920 as required for seismic forces.

  5. Minimum Nominal Cover Clear cover shall be provided • To develop the desired bond strength through out the perimeter of steel • To protect against corrosion and fire • Slab 20mm • Beam 25mm • Column 40mm • Footing 60mm For detail see Table-16 IS 456-2000

  6. Spacing of reinforcement The horizontal distance between two parallel main reinforcing bars shall not be less than The diameter of the bar if the bars are of equal diameter The diameter of the larger bar 5mm + nominal size of aggregate Maximum spacing ----as per design Further reading Page 167 A. K. Jain Clause 26.3.2, IS456-2000

  7. Limits for reinforcement Clause 26.5, IS456-2000 Beam Min As/bd = 0.85/Fy Maximum = 4% of bD Compression = 0.2% Web reinforcement = 0.1% of web area Vertical Shear bars not exceeding 0.75d or 300mm whichever is less. Minimum shear bars = cl 26.5.1.6 Slab = min 0.12% for Fe415 and 0.15% for Fe250

  8. The stirrups shall be minimum size of 8mm in the case of lateral load resistance . • The hooks shall be bent to 135 degree . • In column size of bar not less than 12 mm • Spacing of bars not greater than 300mm • Arrangement of lateral ties as per cl 26.5.3.2

  9. DEVELOPMENT LENGTH OF BARS FOR A CONCRETE GRADE M20 &STEEL STRENGTH Fy=415 APPROXIMATELY USE 50Xdia FOR TENSION

  10. Lap splicing -clause 26.2.5.1 IS456-2000

  11. Lap splicing as per clause 26.2.5.1 IS456-2000 Lap splices should not be used for bar larger than 36mm Larger than 36mm bar may be welded Lap length including anchorage value of hooks in flexural tension is development length (Ld)or 30ϕ whichever is greater. Lap length including anchorage value of hooks in direct tension is 2Ld or 30ϕ whichever is greater. The straight lap length should not be less than 200mm or 15ϕ whichever is greater.

  12. Lap splicing Cont.…. Lap splices are considered as staggered if the c/c distance of the splices is not less than 1.3 times the lap length. The lap length in compression is equal to the development length in compression but not less than 24ϕ. Lap length is calculated on the basis of diameter of smaller bar when bars of different diameters are to be spliced.

  13. DO’S For Detailing • Prepare drawing properly and accurately • Prepare bar bending schedule, if necessary • Indicate proper cover to the reinforcement • Decide location of the openings/hole and supply adequate details for the reinforcement around openings. • Commonly available size of bars and spirals shall be used for reinforcement.

  14. For a single structural member the number of different sizes of reinforcement bar should be minimum. • The grade of reinforcement bars should be clearly mention in the structural drawings • When reinforcement is left exposed for future construction, it should be adequately protected from corrosion and weathering. • Congestion of the reinforcement should be avoided at points where members intersect and make certain that all the reinforcement shown can be properly placed. • Show enlarged details at the corners, beam and column joint and at similar special situations.

  15. Do Not's for Detailing • Flexure reinforcement shall not be terminated in a tension zone. • Lap splices should not be used for bars larger than 36 mm dia. • Different types of reinforcing bars such as deformed bars and plain bars and various grades should not be used side by side as this practice would lead to confusion at site.

  16. Do’s for Columns • A reinforced column should have min 4 bars for rectangular or square column and minimum 6 bars for circular columns. • Keep outer dimensions of the column constant, as far as possible, for re-use of forms. • Preferably avoid use of two grades of vertical bars in the same element.

  17. Do’s for Beams and Slabs • Where splices are provided in the reinforcing bars, they should be staggered, and away from the sections of maximum stress. • Where the depth of the beam exceeds 750 mm in case of beams without torsion and 450 mm with torsion side face reinforcement shall be provided. • All spacing shall be c/c spacing of the bars.

  18. Deflection in beams/slabs may be reduced by providing compression reinforcement. • At beam column intersection ,ensure that the main beam bars avoid the main column bars. • At beam column intersections , main reinforcement may be so arranged that layers in mutually perpendicular beams are at different levels. • To accommodate bottom bars, it is good practice to make secondary beams shallower than the main beams at least by 50 mm.

  19. Curtailment of reinforcement Clause26.2.3 IS456

  20. Cont.…

  21. Cont.… Positive moment reinforcement, Cl26.2.3.3 Negative moment reinforcement,Cl26.2.3.4 Curtailment of bundled bars,Cl26.2.3.5 Further reading A. K. Jain p 172 Simplified rules of curtailment as per BS 8110-1985

  22. Bar Bending Schedule Bar Bending Schedule should include: • Identification of structural member • Position of each bar in the member • Bar marks and diameter of each bar • Number of bars • Shape and bending dimension of each bar • Length of each bar • Remark, if any Typical example for slab, beam and column: see page 180 (A.K. Jain)

  23. IS13920:1993,Ductile Detailing of RCC Structures Subjected to Seismic Forces • This code applies to all RCC structures which satisfy one of the four conditions- • The structure is located – • In zone IV or V • In zone III and I> 1.0 • In zone III and industrial structure • In zone III and is more than 5 story high

  24. What is EQ Resistant Design? The acceptable response levels of the structure under design earthquake. Designer should exercise some degree of control on magnitude and distribution of stiffness, mass and relative strength of member and their ductility to achieved desired results.

  25. Seismic Design Criteria(IS 1893)

  26. If elastic strength of structural elements exceeds the greatest imposed load upon that structure there can be no significant damage. In severe earthquake some of the resisting elements will be loaded to their full strength. If they are brittle, they will fail, throwing their share of the load on the remaining elements. If they are ductile, they can continue to participate in resisting the lateral force up to their full strength after they yield.

  27. DUCTILITY • A ductile material is the one that can undergo large strains while resisting loads • Ductility implies the ability to sustain significant inelastic deformations prior to collapse. • Brittle material is one that fails suddenly upon attaining its maximum load

  28. Brittle Brittle and Ductile force-deformation behavior Force Ductile Δy Δu Deformation

  29. Significance of Ductility It can be expected to adapt to unexpected overloads, impact and structural movements due to foundation settlements and volume changes. Occupants will have sufficient warning of the impending failure thus reducing the probability of loss of life in the events of collapse. All joints and splices must be able to withstand forces and deformations corresponding to yielding of the reinforcement.

  30. Design for Ductility Structural layout should be simple and regular. Amount of tension reinforcement in beams should be restricted and more compression reinforcement should be provided.

  31. Cont.…

  32. Cont.… The shear reinforcement should be adequate to ensure that the strength in shear exceeds the strength in flexure and thus, prevent a non-ductile shear failure before the fully reversible flexural strength of a member has been developed. See on clause 6.3.3 in IS13920

  33. BEAMS • At least two bars should be provided continuously both at top and bottom. • The positive moment resistance at the face of the joint should not be less than one –half of the negative moment resistance provided at that face of the joint. • Neither the negative nor the positive resistance at any section along the member length should be less than one-fourth of the moment resistance provided at the face of the either joint Clause 6, IS13920

  34. MIN 2 BARS FOR FULL LENGTH ALONG TOP AND BOTTOM FACE AS > MIN. Bd AS < MAX Bd 50 mm max 50 mm max d db 2d 2d HOOP SPACING > d /2 HOOP SPACING < d/4 and 8 db B = BREADTH OF BEAM db = DIAMETER OF LONGITUDINAL BAR BEAM REINFORCEMENT

  35. Spacing of hoops over a length of 2d at either end of the beam shall not exceed- • d/4 • 8 times the diameter of the smallest longitudinal bar, need not be less than 100 mm • Elsewhere, the beam shall have vertical hoops at a spacing not exceeding d/2. Clause 6.3.5, IS13920

  36. COLUMN

  37. Cont.… The special confining reinforcement shall be provided above and below the beam connections, in a length of the column at each end which is largest of the following- 1/6 of the clear height of the column Larger dimension of the column 450 mm When a column terminates into a footing, special confining reinforcement shall extend at least 300 mm into the footing

  38. SPECIAL CONFINING REINFORCEMENT > 300 mm PROVISION OF SPECIAL CONFINING REINFORCEMENT IN FOOTINGS

  39. lO JOINT REINFORCEMENT AS PER 8.1 lO > hc/ 4 SPECIAL CONFINING REINFORCEMENT AS PER 7.4.1 TRANSVERSE REINFORCEENT AS PER 7.3.3 SPLICE TRANSVERSE REINFORCEMENT AS PER 7.2.1 hC > hc/ 4 lO CONFINED JOINT WITH BEAMS FRAMING INTO ALL FOUR SIDES CONFINING REINFORCEMENT AS PER 8.2 COLUMN AND JOINT DETAILING

  40. The spacing of hoops used as special confining reinforcement shall not exceed – • ¼ of the minimum member dimension • need not be less than 75 mm nor more than 100 mm • For further information see on Clause 7.4.6 and 7.4.7 in IS 13920

  41. Ld + 10db db Ld + 10db Ld = DEVELOPMENT LENGTH IN TENSION Db= BAR DIAMETER FIG. 1: ANCHORAGE OF BEAM BARS IN AN EXTERNAL JOINT.

  42. LAP SPLICES IN BEAM • Not more than 50 % of the bars shall be spliced at one section • The longitudinal bars shall be spliced , only if hoops are provided over the entire splice length, at a spacing not exceeding 150 mm • The lap length shall not be less than the bar development length in tension. Clause 6.2.6 IS13920

  43. Cont.… Clause 6.2.6 IS13920 • Lap splices shall not be provided- • within a distance of 2d from the joint face • within a joint • within a quarter length of the member where flexural yielding may generally occur under the effect of earthquake forces. • Use of welded splices and mechanical connections may also be made as per IS456-1978

  44. Ld db 150 mm Ld = DEVELOPMENT LENGTH IN TENSION db= BAR DIAMETER FIG. 2: LAP, SPLICE IN BEAM

  45. Web Reinforcement Clause 6.3 IS13920

  46. Cont.….

More Related