Routine Calibration Activities

Routine Calibration Activities The routine phase will start at the end of the commissioning phase. The routine calibration is composed mainly of: Spectral calibration Radiometric calibration Vicarious calibration. Systematic Calibration Activities Radiometric calibration

lorand
Télécharger la présentation

Routine Calibration Activities

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Routine Calibration Activities • The routine phase will start at the end of the commissioning phase. • The routine calibration is composed mainly of: • Spectral calibration • Radiometric calibration • Vicarious calibration

  2. Systematic Calibration Activities • Radiometric calibration • White Diffuser 1. Every 15 days • White Diffuser 2. Every 3 months. Spectral calibration • Spectrometric calibration • Pink spectralon diffuser Every 3 months. • Vicarious calibration • Aos: Systematic data extraction and distribution (Metric)

  3. Calibration Campaigns • Radiometric characterization • Observation of White Diffuser 1: Every 3 months • Spectrometric characterization • Fraunhofer analysis. Once per year. • Oxygen analysis. Once per year. • Vicarious calibration • Aos: Campaign data extraction and distribution

  4. IECF Instrument Engineering Calibration Facility

  5. IECF Operational Concept • Execution of Calibration Algorithms (Algorithm Processor) • Generation of Reports (Report Builder) • (Visualization of data) • Handling of ADF files and CTI tables (ADF/CTI Builder) • (Generation, Validation, Dissemination)

  6. Main IECF Calibration Functions • F1: Blank Pixels and Coarse Offsets • F2: Generation and Comparison of Radiometric Gain and Radiometric Offsets Values • F4: Generation of the Spectrometric Values • F5: Blank Pixels, VEU Temperature and CCD Temp • F6: Radiometric Calibration Report • F16: Generate MER_RAC_AX using ADF_Builder

  7. Blank Pixels Signal CCD and VEU Temperature Main IECF Reports

  8. User defined execution (e.g.: Algo Processor, Report Builder and ADF Builder) User defined input data User defined configuration parameters Processing Chain • Batch Execution • Association of the execution to a specific event • Event types: • product is arrived into IECF db • timer event (time, absolute orbit,relative orbit)

  9. METRIC • Data extraction over selected sites following specific radiometric and geographic criteria for the absolute calibration of MERIS by vicarious methods. • MER_RR__1P product order on the basis of site definition: • Rayleigh, Glitter, Desert, • Output files in HDF format • FTP server to end user • CNES, RAL

  10. METRIC SITES

  11. METRIC Potential Improvements • Extend the Level 1b surface types to be processed: • Snow/Ice, Buoys (Moby, Ishigaki,Boussole) • (Extraction algorithm needed) • Extend to the level 2 products: • i.e. IOCCG Diagnostic data sites • (Extraction algorithm needed) • Extend the number of instruments to be processed: • Include AATSR

  12. Calibration Methodology • BRDF model • Update of the BRDF model based on in-flight data • (Calibrations Dif 1&2, Observation Dif 1) • Inputs from Vicarious calibration activities • Routine operations • Automatic monitoring of instrument gain • Update of gain coefficients triggered according • to threshold detection (goal < 0.5%) • ADF update using latest Calibration data • Reprocessing Approach • TBD

  13. Status of Routine Operation • IECF transfert to ESRIN being prepared with a target date Mid-November 2002 • Cal / Val plan for the Exploitation phase in progress • Support Contract with ESL for will start in January 2003 • A Quality Working Group will be start in January 2003 • Set of tools for the product quality control have been delivered: • Quarc (automatic QC, mission analysis), • MerisView (Interacative QC), A • Malfi (products final check before delivery)

  14. Routine Calibration Activities: Conclusion • Level 1b is ready to be transfered to operations • Routine CalibrationContinuity of Aos for the vicarious calibration (Metric) • Systematic calibration activity • IECF being transfered in operation (Mid-November) • Cal / Val plan, • Support contract will begin in January 2003 • Quality Working Group will begin in January 2003 • The tools for insuring the product quality are available.