An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ARC202B Week 4 Basement completion

  2. Review • What should the standard size of a masonry joint be? • 3/8” • How can you tell which side of a block is the top? • top has flared webs • When would a pilaster block be used? • to support a beam and at long walls

  3. Review • What are the 4 main ingredients for mortar? • portland cement • masonry mix • masonry sand • water • What type of mortar is most commonly used for residential basements? • type “N”

  4. Review What is the area of a standard stretcher block? • 1.33 * 0.66 = 0.87 square foot

  5. Completing work below grade • After the foundation walls are complete the following can occur: • weeping tile installed • stone placed over weeping tile • granular fill under basement and garage slab • vapour barrier installed over fill • concrete slab poured • back fill around foundation with clean fill

  6. Helical profile Annular profile Weeping tile • Weeping tile ( Big O ) is used to remove water away from the bottom of the basement area • Two types

  7. Weeping tile • When ordering you have different options • Standard corrugated • Perforated corrugated • Perforated corrugated w/ polyester sock filter

  8. Weeping tile locations • Weeping tiles are located where ever the basement is located on both sides of the footings • Crossovers should be located a minimum of one, on every side of the building • Should not be smaller then 4” diameter

  9. Calculating weeping tile • (Length of basement wall’ * 2) + (crossovers length’ * 4) = linear feet of weeping tile

  10. Granular fill • Granular fill over weeping tile and under basement slab should be 3/4” clear crush stone • Weeping tile should be covered by at least 6” of stone on top and on the side • A recommendation by the Ontario New Home Warranty Program is to cover the stone with filter fabric to prevent fine sediment from entering the weeping tile

  11. Backfill under garage slab • Sand, foundry sand, 0 to 3/4” granular fill are all used depending on the contractor • This fill should be placed in layers and compacted

  12. Calculating Granular fill • At the weeping tile, calculate for a height 6” over the footing and distance pass the side of the footing • Account for 10% swelling for basement slab & weeping tile fill • Under garage slab 0 to 3/4” granular fill will be used • Account for compaction and 20% swelling

  13. Assignment • Calculate • Total cubic yards of granular fill for 3/4” clear stone • Total cubic yards of 0 to 3/4” granular fill • Total linear feet of drainage tile • Total square feet of filter fabric over weeping tile on outside of foundation wall only • Total linear feet of expansion joint • Total square feet of vapour barrier under slab • Total cubic meters of concrete for the interior floor slabs

  14. Assignment • Reference • add 5% waste for concrete & vapour barrier • filter fabric starts at foundation wall, out to outer edge of granular over weeping tile

More Related