1 / 7

Online Energy calibration inside TileCal RODs

Online Energy calibration inside TileCal RODs. Belén Salvachúa TileCal Valencia Meeting Monday 27th August 2007. Online energy calibration. Requirement: Online calibration of the TileCal Energy in the RODs for 2nd level trigger input. Types of calibration:

lylee
Télécharger la présentation

Online Energy calibration inside TileCal RODs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Online Energy calibration inside TileCal RODs Belén Salvachúa TileCal Valencia Meeting Monday 27th August 2007 B. Salvachua

  2. Online energy calibration • Requirement: • Online calibration of the TileCal Energy in the RODs for 2nd level trigger input. • Types of calibration: • OnlineADCcounts: (plain ADC counts) • OnlinePicoCoulombs: (CIS calibration) • OnlineCesiumPicoCoulombs: (CIS + Cs calibration) • OnlineMegaElectronVolts: (whole calibration chain) B. Salvachua

  3. Online energy calibration • Linear calibration of the type: E [ calibrated ] = a ( b + E [ ADC ] ) b: Offset in ADC counts for all calibration types. a: Energy units conversion factor. • After 2nd level trigger energy can be offline uncalibrated in order to apply a more complicated offline calibration (if required). B. Salvachua

  4. From POOL to the RODs • Calibration constants will be stored in POOL files and inserted into the conditions database (same procedure as current the Optimal Filtering weights). • Read from POOL using: • TileC libraries (Karl) • TileUseDB (Belen) • TilePlugins (Carlos) • Calibration constants are converted on the fly to fixed-point numbers and included in the Optimal Filtering fragment to be uploaded to the ROD DSPs. B. Salvachua

  5. Output data format • New output data format needed to account for energy calibration. • New encoding and decoding of the online energy depends on: • Gain • Calibration energy units • 15-bits are assigned to encode the online energy. B. Salvachua

  6. Output data format details LOW GAIN: HIGH GAIN: B. Salvachua

  7. Status and Conclusions • New DSP version v13r2p2 used in M4 which contains: • online energy calibration mechanism (calibration constants for ADC counts are uploaded to the RODs) • new reconstruction output data format • New fragment type is created (type=4) • Athena decoder is ready (in CVS repository since Friday 24th Aug) • This changes will be validated using M4 data. B. Salvachua