ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI

ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI. 2009. APPENDIX. Contaminated Oil. Pure Oil. COP Vs Load Characteristics. 5.0. 4.5. 4.4. 4.3. 4.0. 3.8. 3.5. 3.4. 3.0. 2.5. COP. 2.0. 1.5. 1.0. 0.5. 0.0. 100 %. 75%. 50%. 25%. Test result based on : 10HP/ 43C. % Load.

Télécharger la présentation

ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI 2009

  2. APPENDIX

  3. Contaminated Oil Pure Oil

  4. COP Vs Load Characteristics 5.0 4.5 4.4 4.3 4.0 3.8 3.5 3.4 3.0 2.5 COP 2.0 1.5 1.0 0.5 0.0 100 % 75% 50% 25% Test result based on : 10HP/ 43C % Load Multi V Tropical Partial Load Data Characterstics RAW DATA

  5. Water cooled outdoor unit Water cooled outdoor unit Air cooled outdoor unit 29%↓ 49%↓ Air cooled outdoor unit Merits of the water cooled system Performance comparison according to the outdoor unit size and temperature effect • Air-Cooled System - COP drop due to Hot air re-circulation at higher elevation • Water cooled system- No hot air re-circulation result intact COP • With the increase in suction temp. Air cooled system COP reduced but water cooled system will have intact COP irrespective of outdoor air temperature

  6. 1) Complete System / b) Operation (C/O) Cooling Tower 99℉(37℃) Bypass Valve Temperature Sensor 90℉(32℃) Interlock Operation Water Pump Control Panel Pumping Operation Signal Room 1 Room 2 Room 3 Multi V Water Outdoor Unit To the other Outdoor Units

  7. MV WATER CYCLIC VIEW Water Supply Flexible Tube • Water Outlet Temperature <2℃ • → System Off -.Water Temperature assurance range 10℃ <Water Temperature < 45℃ Water Return Ball Valve Solenoid Valve Strainer Water Sensor Water Flow Sensor P/T Plug Water Outlet Attach Water Sensor Unit Water Outlet Flange Water Inlet Drain Water Inlet Plate Heat Exchange Plate Heat Exchange

  8. Short tube A CIRCIUT Eva.In Sensor B CIRCIUT Air Sensor By-pass cycle Air Sensor E-Room 48k Air Sensor Eva.Out Sensor D-pipe Sensor D-pipe Sensor S/V1 S/V2 B A D C Eva. Sensor Pipe Sensor A-Room C-Room D-Room Pipe Sensor B-Room Air Sensor BD-1 Eva. Sensor LEV’s MPS MULTI /SINGLE A COMPARISOON Single A : Small condenser for individual evaporators MPS Multi : Big (common) condenser for 2 or more than evaporators.

  9. Installation Convenience Detachablecorner part-Easy hanger adjustment and drain pipe leak checking . Hanger adjustment Detachable corner part Easy leak check from drain pipe connection Refrigerant pipe connection checking Drain / leak check Easy hanger adjustment Easy hanger adjustment

  10. App 40 In your Eco V system , how much is total heat recovery as compared to the conventional systems ? In your Eco V system , how much is total heat recovery as compared to the conventional systems ? High efficiency (approx. 3 times more in case enthalpy heat efficiency)

  11. It normally takes 13 ~18 mins (ST) depending upon type of model and kind of tests to be performed. Based upon Plus II Model : LRP-N23007D

  12. 1. THERMA V Introduction System layout ③ ② ① ④ ⑤ Back up heater ① ② ④⑤ Radiators/ floor Heating/ Water Heating Electric Heat Pump Hydro kit Ref. Water Heat exchange between Ref. To Water Sanitary water tank ③

  13. 1st Quarter / Dealer trip No. 2 / QUE : 6 10. In the CCD, do we need to disassemble the whole unit if we have to fan blower out? Ans No you don’t require to disassemble the whole unit, you can have the access from the top and bottom side. From there you can disassemble the fan blower. 2007/2008 2005/2006 System • Multiple assembly • Easy service and maintenance • -.Can remove fan motor or blower without • disassembling whole blower deck. • Plastic blower and housing, light to handle. • Single assembly • Separate all assembly when there are • problems inside blower deck assembly Point

  14. ECO V FILTER Air filter • Collection efficiency above 80% • Cleans particle size smaller than 0.3 micro meter (smaller than tobacco smoke) • Low pressure loss • Excellent washable characteristics Optional filter • Collection efficiency above 99% • Low noise • Low pressure loss