650 MDS Multiparameter Display System
Outline • Layout • Front & Rear Covers • Keypad & Characters • Interfacing • With: • Sonde • Sonde & GPS • PC • Battery Charger Quick Tips Look here for tips on using the 650 MDS
Outline • Operating the 650 • Menus • Calibrating a sonde & UNCAL • Logging • Available Memory • Files • Site Lists • Parameter Mismatch • File Management • Uploading Files from sonde • Downloading to PC • Upgrading Software • Q & A
Layout Front Cover Display On/Off Quick Tips Both the handstrap and lanyard can be switched to either side for ease of use. Arrow Keys Backlight Key Escape Key Enter Key Handstrap Keypad MS-8 Connector Strain Relief Lanyard
Layout Rear Cover Accessory Connections Battery Lid Screws Barometer Patch Vent Battery Lid
Layout Keypad Backlight Key On/Off Arrow Keys Enter Key Escape Key Keypad
Layout Keypad • 1 = 1 • 2 = ABC2abc2 • 3 = DEF3def3 • 4 = GHI4ghi4 • 5 = JKL5jkl5 • 6 = MNO6mno6 • 7 = PQRS7pqrs7 • 8 = TUV8tuv8 • 9 = WXYZ9wxyz9 • - = Minus/Hyphen • 0 = 0 • . = Period/Decimal Point Quick Tips To access the multiple characters associated with each key, just keep pressing the key until the character you want appears.
Interfacing • With: • Sonde • Sonde & GPS (user supplied) • PC • Battery Charger
Interfacing a 650 with a Sonde • 650 MDS • Integral or Detachable Field Cable • YSI 6-Series Sonde Here’s the list of what you need: • 650 MDS • Field Cable • 6-Series Sonde
Interfacing a 650 with a Sonde & GPS • 650 MDS • User supplied GPS unit w/DE-9 Cable • GPS Y-cable (6115) • Integral or Detachable Field Cable • YSI 6-Series Sonde Here’s the list of what you need: • 650 MDS • GPS w/DE-9 Cable • GPS Y-Cable • Field Cable • 6-Series Sonde
Interfacing a 650 & PC • 650 MDS • PC Interface Cable (6112) • Personal Computer Here’s the list of what you need: • 650 MDS • PC Adapter Cable • PC • *USB to RS232 Adapter
Interfacing with a Battery Charger • 6113 Battery Pack Kit • 6116 Adapter Cable • 6123 Wall Charger • 6117 Rechargeable Battery • 650 MDS Here’s the list of what you need: • 650 MDS • 6113 Battery PackKit
Operating the 650 Menus When you turn the instrument on, this is the first screen to appear. • GPS information • Date & Time • Barometer Reading • Battery life • Menu Icon
650 Main Menu Continued... Run Screen Sonde run Directory Upload to PC View file File memory Delete all files Sonde menu File Version Date & Time Power Sonde Baud rate to sonde Shut off time Comma radix ID Circuit Board Serial # Barometer Units Calibrate Barometer Interval Use site list Store Barometer Store Lat and Long Store site number Edit Site List Logging Setup System Setup 650 Flow Chart
Sonde Menu Flow Chart Sonde Menu Discrete Sample Unattended Sample Conductivity DO % DO mg/L Various other Parameters Run Directory Upload to PC Quick Upload View File Quick view file Delete all files Calibrate Version Date Time Bat volts Bat life Free bytes Logging File Status Date & Time Comm setup Page length Instrument ID Circuit Board SN GLP filename SDI-12 address Language System Report “Report setup” includes a list of all enabled sensors. “Sensors enabled” gives a list of all available sensors and shows if they are enabled. Sensor Cal constants Setup Sensor Data filter Advanced
Calibration using the 650 • From the 650 Main Menu: • Select ‘Sonde menu’ • Highlight ‘Calibrate’ • Choose Calibration mode • Follow instructions on screen • Screen will show ‘Calibrated’ when calibration is complete • When screen shows ‘Continue’ press • Press to continue calibration of other sensors
Calibration 650 Main Menu Main (Sonde Menu)
Calibration Calibration DO % Calibration Menu
Calibration DO % Calibration Barometric Pressure Choice to calibrate
Calibration Calibrated Continue Final Screen (once finished it backs you out)
The ‘UNCAL’ Procedure • Access the calibration routine for the sensor you want to ‘uncal’. • Instead of entering numbers • Press and hold the key • Press the key. Quick Tips The Uncal Procedure can be helpful if a calibration was done incorrectly or if an ‘out of range’ calibration was accepted. It resets the unit back to factory calibration.
650 Logging Available Memory • Low Memory • 12 File Names • 100 Site Names • High Memory • 35 File Names • 100 Site Names
Logging to the 650Simple Logging • From the Main Menu highlight Logging setup. Press . • The ‘Use site list’ should be inactive. • Set the interval to 5 seconds (00:00:05) and press . • Press . • Highlight Sonde run and press .
Logging to the 650Simple Logging • You should now see the Run screen:
Logging to the 650Simple Logging • Enter “Pond” for a file name. • Press . Once you have entered all the information, highlight OK and hit enter. On the 650 side you should see a blinking ‘Sample Logged’
Logging to the 650Using a Site List • Press until you return to the Main Menu. • Under Logging Setup, Highlight ‘Use site list’ and press . • Highlight ‘Edit Site List’ and press . Remember Every file name and site name will take up space in the 650 memory.
Logging to the 650Using a Site List • For file name enter “BLUELAKE”. • For each site name and site number, set them up as in the example below: Remember Every file name and site name will take up space in the 650 memory.
Logging to the 650Using a Site List • Once your site list is set up, press until you reach the Main Menu. • Highlight Sonde run and press . • Select ‘start logging’ under the 650 menu and press .
Logging to the 650Using a Site List Remember If you choose a file/site number that already has data, the parameters must be exactly the same.
Logging to the 650Parameter mismatch • Use this chart to Troubleshoot a Parameter Mismatch:
File ManagementUploading: from Sonde to 650 • From the Main Menu, highlight Sonde menu and press . • Highlight File and press . • Select Upload or Quick Upload and press . Choose PC6000 format for the fastest download and direct readability in EcoWatch
File ManagementUploading: from Sonde to 650 • You should be able to watch the upload process on the screen:
File ManagementDownloading: from 650 to PC • You will need your PC adapter cable. • From the 650 Main menu, • File • Upload to PC • Select your file name, press .
Upgrading 650 Software • You will need your PC interface cable. • Download the YSI Code updater from www.ysi.com • Run Installer on your PC • Go to - Start, Programs, YSI Code Updater. • Set the comm port, and press ‘Start Code Update’
Additional Hints • Adjust contrast by holding down the BackLight key and pressing the Up / Down arrow keys • GPS readings can ONLY be logged to 650 memory - the system does NOT support logging to Sonde memory • GPS data is reported different in EcoWatch then what it is on the 650