1 / 38

PV Backsheets from Hanita Coatings

PV Backsheets from Hanita Coatings. Avi Amar – Hanita Coatings Energy Efficiency Division 2012. Why should you choose Hanita?. Hanita Coatings offers 30 years’ expertise developing engineered polymeric films. Established – 1982 HQ, R&D and manufacturing in Western Galilee, Israel

maude
Télécharger la présentation

PV Backsheets from Hanita Coatings

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PV Backsheetsfrom Hanita Coatings Avi Amar – Hanita CoatingsEnergy Efficiency Division 2012

  2. Why should you choose Hanita?

  3. Hanita Coatings offers 30 years’ expertise developing engineered polymeric films • Established – 1982 • HQ, R&D and manufacturing in Western Galilee, Israel • Ownership – • 75% Kibbutz Hanita • 25% Tene Investments • 180 staff, 7 overseas sales offices • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  4. Hanita’s global reach ensures short lead-times and outstanding local service • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  5. State-of-the art coating and laminating facilities provide innovative technological solutions Four coating lines 1.6-2.1m wide, 0.7m pilot production line, clean room – Class 100,000 • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  6. Technology break-throughs in the field of metallizing enable us to provide world-leading levels of barrier Two vacuum roll coaters, 2.1m, 2.3m wide, proprietary deposition of Al, Cu, and other metals, alloys and oxides • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  7. Recent CAPEX investments of $15m provide the cutting edge of technology Six slitter-rewinders with width capacity from 5mm – 2100mm, Clean room – Class 10,000 • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  8. We offer a unique range of capabilities and processes under one roof Deposition & Metallizing Technology Coating & Laminating Technology Print Primers Adhesives Barrier Coatings Abrasion Resistant Coatings Nano Coatings Ultra Violet Reduction Atmospheric Plasma Optical Density 0.2-5 Enhanced Metal Adhesion Reactive Depositions Clear Barrier Technology R&D Engineered Films Industrial & Graphics Energy Efficiency Solutions Markets • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  9. With all production in one site, we can guarantee total quality control • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  10. A fully equipped testing lab ensures all products are rigorously tested for durability & performance • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  11. All backsheets we develop are rigorously tested as complete modules by external laboratory • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  12. Our products combine the finest raw materials from leading manufactures EVA Films PET Films Fluoro-polymeric Films Fluoro-polymeric coatings Ultra-white patent pending EVA layer gives high VIS light reflectance (higher output power from the module) + good adhesion to EVA encapsulant. Selected to provide the required electrical insulation and mechanical strength. Arkema Kynar® films give outstanding protection from weathering In-house coating development cost effectively provides the weatherability levels of FP films • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  13. Hanita Coatings’ strengths ensure we can challenge the market leaders R&D - Custom Development • 12% workforce R&D dedicated • ISO 9001:2008 • Fully equipped Test lab • Advanced film converting facility • Deep specializationin durable coatings • Distribution centers worldwide Global Reach 30 years’ expertise • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  14. Why choose DuraShield backsheet products?

  15. Look what can happen if you use the wrong backsheet… Corrosion in connections caused by cracks in backsheet Delamination of BS after 3 yearsexposure in Germany • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  16. All DuraShield backsheets provide high physical protection, electrical insulation & the right appearance Physical protection Enabling a 25 year outdoor PV module lifespan Increased efficiency in some applications Electrical insulation Right appearance Moisture protection • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  17. Hanita produces four types of backsheets (BS) for the leading PV technologies DuraShield KPE Fluoropolymer laminate BS, for c-Si modules DuraShield CPE High durability FP coated laminate BS, for c-Si modules DuraShield KAPE Low weight, high barrier BS solution for Thin Film technologies DuraShield Back Contact Electrical circuit backsheet for Back Contact (EWT/MWT) technologies • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  18. DuraShield KPE’s classic FP film construction delivers enhanced long-term performance for c-Si modules DuraShield KPE K = Kynar® PVDF Fluoropolymeric film P = Polyester film E = EVA • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  19. DuraShield KPE is a proven technology targeting traditional module manufacturers Cost Effective Economical alternative to PVF constructions Enhanced Reflectivity Exceptionally white EVA layer Excellent Durability Long term weatherability retains bright whiteness and reflectivity • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  20. DuraShield KPE is TUV certified for >1000VDC and UL IEC 61730-2:2004 Maximum permissible 1053 VDC System voltage • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  21. DuraShield KPE easily withstands 2000 hours damp heat 2000 hours testing • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  22. DuraShield CPE replaces the Kynar FP film laminatewith an equally durable Fluoropolymeric coating DuraShield CPE Cost Effective C = Coating of Fluoropolymer P = Polyester film E = EVA • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  23. The DuraShield CPE solution delivers a price advantage without compromising performance Fluoropolymer Coating EVA PET Patent pending ultra-white EVA layer gives high VIS light reflectance (higher output power from the module) + good adhesion to EVA encapsulant. Provides electrical insulation and mechanical strength. Protected by Fluoropolymer layer. Gives protection from weathering, cost effectively. • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  24. DuraShield KPE gained TUV & UL approval. So did the competitors. Look what happened after 2000 hours… Competitor Backsheet DuraShield KPE ∆E = 2.0 ∆E = 4.4 Market leading competitor’s backsheet yellows drastically after aging test of 2000 hours of damp heat. DuraShield KPE is more reflective and more effective than the competitor’s leading product. • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  25. DuraShieldKPE and CPE show outstanding long term EVA encapsulant peel strength DuraShield KPE DuraShield CPE – FP coating – PET based – FP film x2 – DuraShield CPE – DuraShield KPE Damp Heat Test Damp heat: 85 OC 85% RH • Why Hanita Backsheets: KPECPE KAPE Back-Contact Custom

  26. DuraShield’s ultra-white EVA shows exceptional initial cell-side reflectance DuraShield KPE DuraShield CPE – FP coating – PET based – FP film x2 – DuraShield CPE – DuraShield KPE DuraShield KPE visible light reflectance (550nm): 84.4% DuraShield CPE visible light reflectance (550nm): 84.1% • Why Hanita Backsheets: KPECPE KAPE Back-Contact Custom

  27. UV exposure up to 3000 hours shows exceptional performance by DuraShield KPE & CPE @ cell side DuraShield CPE DuraShield KPE – FP coating – PET based – FP film x2 – DuraShield CPE – DuraShield KPE Test cycle: 20h UV-A (0.93W/sq.m,@340nm) + 75°C ; 4h dark + 50°C + condensation

  28. DuraShield KPE and CPE both demonstrate excellent color stability – ΔE vs. QUV hours @ back side DuraShield CPE DuraShield KPE – FP coating – PET based – FP film x2 – DuraShield CPE – DuraShield KPE Test cycle: 20h UV-A (0.93W/sq.m,@340nm) + 75°C ; 4h dark + 50°C + condensation According to relevant data, 1 year in Florida direct sunshine is ~956 hours in these test conditions. Backside not directly exposed to sunlight, it will typically see ~15-20% from direct light. Taking this factor into account, ~5000 hours safely simulate 25 years • Why Hanita Backsheets: KPECPE KAPE Back-Contact Custom

  29. DuraShield KPE and CPE retain their initial levels of gloss (60°) for 3000 hours virtually without change DuraShield KPE DuraShield CPE – FP coating – PET based – FP film x2 – DuraShield CPE – DuraShield KPE Test cycle: 20h UV-A (0.93W/sq.m,@340nm) + 75°C ; 4h dark + 50°C + condensation

  30. Hanita has developed backsheets for alternative & promising PV technologies DuraShield KAPE DuraShield Back Contact Low weight, high barrier BS solution for Thin Film technologies Electrical circuit BS for Back Contact/MWT technology DuraShield Back Contact Electrical circuit BS for Back Contact (EWT/MWT) technologies • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  31. DuraShield KAPE delivers the high moisture and oxygen barrier demanded by thin film modules DuraShield KAPE K = Kynar® black PVDF Fluoropolymeric film A = Aluminum P = Polyester film E = Black EVA • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  32. DuraShield KAPE is TUV certified for >1000VDC Maximum permissible 1092 VDC system voltage • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  33. Back Contact breakthrough technology improves cell module power output distribution

  34. DuraShield Back Contact foil innovation enables greater efficiency at reduced cost DuraShield Back Contact • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  35. DuraShield Back Contact foil innovation enables greater efficiency at reduced cost DuraShield Back Contact • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  36. Our specialty is customized backsheet development, providing the solution to your specific product challenge Problem: LCPV low concentrated PV modules suffer accelerated module degradation Problem:unconventional encapsulant material Goal: improve affinity to BS Goal: Improve weatherability Solution: Engineering of BS surface by primer or co-ex development, or by replacing EVA with alternative film. Solution: Engineering EVA to enhance UV resistance • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  37. So how can Hanita help you solve your product challenge? R&D - Custom Development • 12% workforce R&D dedicated • ISO 9001:2008 • Fully equipped Test lab • Advanced film converting facility • Deep specializationin durable coatings • Distribution centers worldwide Global Reach 30 years’ expertise • Why Hanita Backsheets: KPE CPE KAPE Back-Contact Custom

  38. Thank you!pv@hanitacoatings.com

More Related