1 / 16

QUAD SYM  TECHNOLOGY

QUAD SYM  TECHNOLOGY. Lens Dynamics, Inc. Wheat Ridge, CO. QUAD SYM  TECHNOLOGY. Based on Quadrant Specific Technology. Can be the entire B.C. radii in one quadrant or just in the edge. Is it the full piece of the pie or just the crust?. DEFINE QUADRANTS.

mikaia
Télécharger la présentation

QUAD SYM  TECHNOLOGY

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. QUAD SYM TECHNOLOGY Lens Dynamics, Inc. Wheat Ridge, CO

  2. QUAD SYM TECHNOLOGY • Based on Quadrant Specific Technology. • Can be the entire B.C. radii in one quadrant or just in the edge. • Is it the full piece of the pie or just the crust?

  3. DEFINE QUADRANTS • Quadrant (Quad) 1 is from 1:30 to 4:30 • Quadrant (Quad) 2 is from 10:30 to 1:30 • Quadrant (Quad) 3 is from 7:30 to 10:30 • Quadrant (Quad) 4 is from 4:30 to 7:30

  4. QUAD SYM B.C. DESIGN • Entire piece of the pie or quadrant. • Allows the lens to have up to 4 different base curves. • The lathe cuts a proper front radii to achieve correct power.

  5. QUAD SYM P.C. DESIGN • Just the edge or crust. • Allows for different edge lifts in all 4 quadrants. • Helpful with edge standoff at 6 o’clock. • Several steps flatter or steeper from Standard edge lift available.

  6. Quad Sym B.C. and Quad Sym P.C. designs can be combined when needed.

  7. HOW TO FIT • Start with a spherical large trial lens – Dyna Intra-Limbal. • Align at least one quadrant and do over refraction. • Document the fluorescein pattern in other quadrants. i.e. Are the other quadrants pooled or touching? • Provide topography. • Lab will design other quadrants based on this information

  8. LATHE LIMITATIONS • Larger diameters cannot be lathed much steeper B.C. than 5.80 mm. • 2.0 mm of spread in B.C.s is maximum. • Some lenses will need to be smaller to achieve needed B.C.s. i.e. 10.2 mm to 10.8 mm diameters

  9. FLUORESCEIN EVALUATION

  10. TOPOGRAPHY • Quad 1 and 4 are steep at 50.00 D. or 6.75 mm. • Quad 2 is moderate at 47.00 D. or 7.18 mm. • Quad 3 is Flat at 40.00 D. or 8.44 mm.

  11. HOW TO FIT • Start with 1 D. flatter than one quadrant. i.e. Quad 3 is 40.00 D. + 1 D. flatter = 39.00 D./ 8.65 mm. • Quad 1 is 49.00 D. + 1 D. flatter = 48.00 D./ 6.89 mm. • Get best alignment in a quadrant. The other quadrants will be steepened or flattened per topography by the lab. • Note the pooling or touch in the other quadrants. Regular Dyna Intra-Limbal on eye • Do over refraction.

  12. Sphere on eye Quad-Sym on eye

  13. WHAT THE ORDER LOOKS LIKE • Base Curve: Quad Sym B.C. design. Q1 & 4 = 49.00, Q2 = 46.00, Q3 = 39.00 • Power: From trial fit 39:00, Total Power = -6.00 • Diameter: 11.2 with 9.4 OZ • Edge: Standard Lift

  14. QUAD SYM P.C. DESIGN • Trial fit with large diameter lens – Dyna Intra-Limbal • Fit with standard spherical B.C. but fitter sees edge problems. • Increase or decrease edge lift in each quadrant as needed. i.e. Trial of 7.50, -3.00, 11.2/9.4 fits well except there is pinch off at 12:00 o’clock and standoff at 6:00 o’clock. • Order: 7.50, -3.00, 11.2 / 9.4, Quad Sym P.C. of Quad 1 & 3 = Standard, Quad 2 = 2 steps Flat, Quad 4 = 4 steps Steep.

  15. QUAD SYM P.C. DESIGN Rx Lens Trial Lens B.C. 7.50 Pwr: -3.00 Dia: 11.2 with 9.4 OZ Edge Lift: Standard B.C. 7.50 Pwr: -3.00 Dia. 11.2 with 9.4 OZ Edge Lift: Q1 & 3 = Standard Q2 = 2 steps Flat, Q4 = 4 steps steep

  16. Questions? Lens Dynamics, Inc.

More Related