بسم الله الرحمن الرحيم. يكاد زيتها يضيء و لو لم تمسسه نار نورً على نور صدق الله العظيم. THE GRID. By Ahmad Mokhtar Hamed Abodahab. No doubt that scattered radiatuon is a great problem disturbing the quality of radiographic image . THE GRID IS a great solution for this problem .

minnies
Télécharger la présentation

بسم الله الرحمن الرحيم

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. بسم الله الرحمن الرحيم يكاد زيتها يضيء و لو لم تمسسه نار نورً على نور صدق الله العظيم

  2. THE GRID By Ahmad Mokhtar Hamed Abodahab

  3. No doubt that scattered radiatuon is a great problem disturbing the quality of radiographic image . • THE GRID • IS a great solution for this problem . • SO ….. What is the grid … & how it work ?

  4. Introduction : • Scattered X ray produced from the patient by Compton effect • It is not useful , really it is a harmful factor to the process of diagnosis . • The intensity of scattered radiation is relativly rallated to : such as * Kv * Beam size * Patient thickness

  5. Steps of solutions of this problem: • As scattered radiation has lower energy than the primary beam , & radiographic film is sensitive to both  increase film sensitivity to the 1 ry beam is the solution . • Using of intensifying screens  improving of image quality , BUT not due to the previous cause .

  6. Selective filter passing 1 ry beam , was not effective • The axtremly effective device for elemenation of scattered X ray was THE GRID .

  7. Structur of the grid : • In 1913 it is invented by Dr.Gustave Bucky • It is a board like device , composed of alternating strips of : * Radiopaque material ( Grid material ) & * Radio translucent material (interspace material )

  8. This structures are encased in an Alumenium case , for : * Rigidity * Protection from moisture . • In Typical grid : • grid strips thickness 50 um , interspace strips 350 um • Up to 12.5% of all photons falling on grid absorbed .

  9. HOW A GRID WORK : • All primary beam photons are passing when falling on interspace strips . • Scattered beams may or may not pass according there angle , if a beam falling by an angle . It will strike grid strip by side  absorbed & not passing to the film .

  10. *1ry beam *Scattered

  11. If a grid is remove about 80 : 90 % of scattered radiation = it has good clean up . • The percentage of absorbed radiation = width of grid strips width of (grid+iterspace ) strips

  12. Characteristics of grid construction: • Certain characteristics are related to the construction of grid identifying its radiographic characters , these are : • 1- GRID RATIO • 2- GRID FREQUENCY • 3- GRID MATERIAL • 4- INTERSPACE MATERIAL

  13. 1- GRID RATIO : • = h or Height of grid strips . D Thickness of interspace • High ratio  less angle of deviation is allowed  more effective clean up .

  14. Increase of Grid ratio is made by : 1- Increase grid height 2- Reduce width of inter space or both • Grid ratio generally 5 : 1 to 16 : 1 • Disadvantages of high ratio : 1- Difficult to be manufactured 2- Need higher exposure to get satisfied image

  15. 2- GRID FREQUENCY : • It is number of grid strips / inch or cm . * Grids with high frequency  less distinct grid lines in film . • Most grids have frequency 60:110/inch i.e. 24: 42 / cm • Disadvantage : Increase frequency  more dose needed , this can be overcomed by decrease thickness of grid strip . ( but this will decrease its clean up )

  16. 3- GRID MATERIAL : • The grid strip should be thin & highly absorber to x ray . • Lead Is the most widely used material due to : * High atomic number * Easy to be shaped * Relatively inexpensive • Other substances : tungsten , platinum , gold & uranium . • Non of these materials is better than lead .

  17. 4- Interspace material : • Aluminum or plastic fibers , are the main substances . • Advantages of aluminum : 1- High atomic number some selective filtration of scattered rays . 2- Give less visible grid lines 3- It doesn't absorb moisture . • Disadvantages : More dose is need with it .

  18. * MEASURING GRID* PERFORMANCE • The principle function of grid is : eliminating of scattered radiation  improve contrast . • Thus to measure grid performance = measure of contrast improvement . • .: grid performance = CONTRAST IMROVEMENT FACTOR ( k )

  19. Contrast improvement factor ( k ) : it is the ratio between contrast with & with out using a grid . k = Radiographic contrast with grid Radiographic contrast without grid • Most grids has (k) 1.5 : 2.5 k= Radiographic contrast with grid Radiographic contrast without grid

  20. Factors affecting it : • High ratio  high k • Heavy grids  high k • High frequency  low k • K is generally measuring at 100 kv

  21. SELECTIVITY (LEAD CONTENT) • In an ideal grid , all 1ry beams transmitted , & all scattered absorbed . • SELECTIVITY ( ) : is the ratio of transmitted 1ry radiation to scattered radiation . • Segma ( ) = 1ry radiation transmitted scattered rad transmitted

  22. Total mass of lead is the main factor affecting selectivity . But proper arrangment is an important factor , if lead strips are adherent to each other  no image will be formed MORE LEAD  HIGHER SELETIVITY

  23. * TYPES OF GRIDS * • Linear grids • Crossed grids • Focused grids • Moving grids

  24. 1- linear grid • It is the simplest grid . • In which all lead strips are parallel . • It is the easiest to be manufactured . • Disadvantage : Grid cutoff ??

  25. 2- Crossed grid : • In which the lead strips running parallel to both axes CROSSING each others . • it is made by sandwiching 2 linear grids , with each strips perpendicular to each others .  it is not too difficult to be manufactured . • Advantages : 1- much more efficient . 2- Easy made , not very expensive . 3- .

  26. Disadvantages : ????

  27. 3-Focused grid : • STRUCTURE : lead strips are angulated in a manner as parts of radiuses of a circle * The source of X ray should be at the center of this imaginary circle , if this not occur  excess cutoff will occur ( so it called FOCUSED ) • Advantage : elemenating of grid cutoff . • Disadvantages : * Difficult manufactured . * Must be focused well . *Producing grid lines ( in each of the previous types )

  28. 4-Moving grids : • Grid lines : Are the shadow lines of the grid strips appearing in the radiograph . It occur due to absorbtion of some 1ry beams by grid strips . • The more wide grid strips more obvious lines . • More frequency  Less obvious lines .

  29. At 1920 , Dr. Hollies potter suggesting to make the grid moving during radio graphing the film, thus a moving grid invented . • By adding moving mechanism to a linear grid , it will become MOVING GRID .

  30. Types of moving grid mechanisms: • Single stroke grid . • Reciprocating grid • Oscillating grid 1- single stroke grid * In which the grid is loaded on a spring & loaded manually • Disadvantages : • Difficult to be used due to the manual cooking of the spring .

  31. 2-Reciprocating grid : It is a grid moving by a motor in each time of exposure . It is moving in to & fro manner . Its main advantages : it is not requiring resetting after each exposure . • 3-Oscillating grid : it is moving in circular manner .

  32. Disadvantages of moving grids : • It require bulky mechanism , which able to be failed . • More distance is need between Film & patient , this give false magnification in the film . • Increase of exposure time . • The movement of the grid , may vibrate the film blurred image . • Stroboscopic effect .

  33. Precautions in using of the grid : Precautions in using of the grid : • Improper positioning is the most frequent problem in using of a stationary grid . • An important 4 situations must be prevented in using of grid : • OFF-LEVEL GRID • OFF-CENTER GRID • OFF-FOCUS GRID • UPSIDE-DOWN GRID

  34. 1- OFF-LEVEL GRID • For proper function of grid , the axis of central beam must be perpendicular on the grid . • If it angulated , the primary beams will absorbed in the grid strips reduced density  OFF-LEVEL GRID {the word meaning cut OFF radiation due to improper LEVEL of grid}

  35. OFF LEVEL

  36. 2-OFF-CENTER GRID : • It occur with focused grid . • If focused grid displaced laterally , & central beam is not in the most central part of the grid  cutoff

  37. T F OFF-CENTER

  38. 3-OFF-FOCUS GRID : • This occur when focused grid used on non proper distance ( as this grid looks like a lens, when it used at improper distance --> improper image ) • With higher grid ratio , more accuracy in distance is needed , any small change in this distance --> off focus .

  39. 4- Upside dowen grid • It occur when focused grid used in an inverted manner ( i.e. It is upper surface looking down ward ) ==> sever cutoff

  40. AIR-GAP Technique • It is a technique used for reducing the scattering radiation . • The film is present at 4 : 6 inches distance from the radio graphed part  scattered beams ( which has low energy not reaching the film) • Some degree of magnification occur with this technique , which can be considered & accepted .