Contents. The functions of an electrical switchboard. The IEC 60439-1standard. Prisma Plus : a structured switchboard based on functional units. Forms: partitioningForms : separations within an assembly. The minimum requirements to guarantee the safety of a LV switchboard. The tests of standard IEC 60439-1.

morty
Télécharger la présentation

Prisma Plus the tested switchboard, complying with standard IEC 60 439-1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Prisma Plus the tested switchboard, complying with standard IEC 60 439-1

    2. Contents

    3. The low voltage switchboard A vital link for electrical distribution

    4. The low voltage electrical switchboard Definitions

    5. The functions of an electrical switchboard To group and protect against external influences the protection and control devices and all their electrical and mechanical connections.

    6. The functions of an electrical switchboard Definitions Some of the components or specificities of the switchboard realize and/or guarantee its finalities, in functional term :

    7. The IEC 60439-1 standard The IEC 60439-1 standard gives general rules for switchboards construction to meet with safety and availability needs required by the application guarantees the minimum level of safety of people and equipment concerns the low-voltage switchgear and controlgear assemblies for the power distribution and control. states : - the service conditions (temperature...) - the construction requirements (IP, IK, forms,...) - the tests requirements

    8. Prisma Plus : a structured switchboard based on functional units This modular design brings much clearness to the switchboard : incoming unit current distribution units feeder units distribution units connection units communication units

    9. IEC 60439-1 Standard and Prisma Plus : a structured switchboard based on functional units Incoming units : incoming circuit breaker (Masterpact, Compact NS, Interpact INS...).

    10. Forms: partitioning In most installations, Prisma Plus cubicles do not require partitioning, Schneider Electric offering options and features that go well beyond the recommendations of the standard : front plates requiring a tool to be removed doors providing access to live parts are keylocked systematic installation of terminal shields on Compact NS circuit breakers and Interpact INS and INV switch-disconnectors upstream and downstream terminals on the incoming device are covered The protection of people and equipment is ensured on origin However, Prisma Plus offers different levels of partitioning to create separations inside the cubicles and thus create Form 2,3 and 4, as defined by the standard.

    11. Forms : separations within an assembly

    12. Forms : separations within an assembly Form 1 : no separation within the enclosure.

    13. The minimum requirements to guarantee the reliability of a LV switchboard First of all, it must comply with standards :

    14. The tests of standard IEC 60439-1 7 type tests : n1 - temperature rise limits n2 - dielectric properties n3 - short-circuit withstand n4 - protective circuit effectiveness n5 - clearances and creepage distances n6 - mechanical operation n7 - degree of protection

    15. 7 type tests performed by the manufacturer The aim of these tests is to confirm the switchboard characteristics.

    16. Test n1 (8-2-1) :Temperature rise limits Guarantees the safety and reliability of the switchboard, by avoiding problems such as : connection damages reduction in insulation performances risk of burn for maintenance operators electronic components damages faulty operation of the devices : inopportune release

    17. Test n1 (8-2-1) :Temperature rise limits Conditions

    18. Test n1 (8-2-1) :Temperature rise limits Results

    19. Test n2 (8-2-2) : dielectric properties Guarantees the switchboard safety and reliability , to avoid problems such as : electrical arc generation insulation performance decreasing connection damages

    20. Test n2 (8-2-2) : dielectric properties

    21. Test n2 (8-2-2) : dielectric properties Results

    22. Test n3 (8-2-3) : short-circuit withstand This test simulates an incident which could occur on site

    23. Test n3 (8-2-3) : short-circuit withstand

    24. Test n3 (8-2-3) : short-circuit withstand Results

    25. Test n4 (8-2-4) : effectiveness of the protective circuit The effectiveness of the protective circuit is verified by two tests : resistance measurement of the connection between the exposed conductive parts and the protective circuits short-circuit withstand performed between the protective conductor and the nearest phase conductor.

    26. Test n4 (8-2-4) : effectiveness of the protective circuit

    27. Test n4 (8-2-4) : effectiveness of the protective circuit Results

    28. Clearance control : shortest distance between two conductive parts. Creepage distance control : shortest distance along the surface of an insulating material between two conductive parts.

    29. Test n5 (8-2-5) : clearance and creepage distances

    30. Test n5 (8-2-5) : clearance and creepage distances Results

    31. Test n6 (8-2-6) : mechanical operation Endurance of material, guaranteeing the longevity of the various mechanisms.

    32. Test n6 (8-2-6) : mechanical operation

    33. Results Test n6 (8-2-6) : mechanical operation

    34. Test n7 (8-2-7) : degree of protection

    35. Test n7 (8-2-7) : degree of protection

    36. Test n7 (8-2-7) : degree of protection Results

    37. The IP degrees of protection : (IEC 60529/EN 60529) 1st digit: protection of persons protection against solids.

    38. Degree of protection The IEC 60529 standard (02/ 2001) gives , by the IP code, the different degrees of protection provided by an electrical enclosure.

    39. IK code : 2 digits giving the level of shock energy, in Joules : IK 01 : 0,14 IK 02 : 0,2 IK 03 : 0,35 IK 04 : 0,5 IK 05 : 0,7 IK 06 : 1 IK 07 : 2 IK 08 : 5 IK 09 : 10 IK 10 : 20. Degree of protection : IK (IEC 62262)

    40. 3 routine tests performed by the panelbuilder The 3 routine tests, easily and rapidly performed, must be carried out by the panelbuilder. : overall inspection according to the mounting instructions and technical documents (right device ratings, tightening torques) insulation checking by a dielectric test checking of protective measures and of the electrical continuity of the protective circuits.

    41. Test n8 (8-3-1) : cabling, electrical operation

    42. Test n8 (8-3-1) : cabling, electrical operation

    43. Test n8 (8-3-1) : cabling, electrical operation Results

    44. Test n9 (8-3-4) : insulation resistance / (8-3-2) : dielectric test

    45. Test n9 (8-3-4) : insulation resistance / (8-3-2) : dielectric test

    46. Test n9 (8-3-4) : insulation resistance / (8-3-2) : dielectric test Results

    47. Test n10 (8-3-3) : protective measures

    48. Test n10 (8-3-3) : protective measures

    49. Test n10 (8-3-3) : protective measures Results

    50. Panelbuilder and manufacturer, together to offer maximum safety and realibility Manufacturer : products tested in real configurations detailed instructions for fautless construction.

    51. Panelbuilder and manufacturer, together to offer maximum safety and realibility Panelbuilders (and installators workshops) : they complete a work of quality, simply they minimize the risk related to their responsibility for realization of a switchboard of which they know and ensure the level of safety they carry out very simply the conformity to the standard, therefore CE marking they develop their professionalism by making known it they are different from the other panelbuilders they profit from the transfer of Schneider Electrics experiment and tools

    52. Prisma Plus and IEC 60439-1 standard : an international influence IEC 60439-1 : the same standard for all the professionals of switchboards