1 / 14

New “Cube” Particle Detector for the Gamma ray and Neutron detection

This article presents the "Cube" scintillation detector assembly for gamma-ray and neutron detection. The assembly consists of a thick scintillator with a 20 cm thickness and a 0.25 sq. meter area, which has a 20% efficiency in registering neutral components with a detection threshold of approximately 5 MeV. Surrounding the thick scintillator are thin scintillation detectors with a 1 cm thickness and a 1 sq. meter area, which have a 3% efficiency in registering neutral components and a 98% efficiency in registering charged components, with a detection threshold of approximately 1 MeV. The light collection scheme is realized using fiber optics. The article also discusses the logic for separating the neutral components.

mtwilley
Télécharger la présentation

New “Cube” Particle Detector for the Gamma ray and Neutron detection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New “Cube” Particle Detector for the Gamma ray and Neutron detection K.Avakyan, A. Alikhanyan National Laboratory, Armenia; K.Arakelyan, A. Alikhanyan National Laboratory, Armenia; A.Daryan, A. Alikhanyan National Laboratory, Armenia; G.Hovsepyan, A. Alikhanyan National Laboratory, Armenia; D. Sargsyan, A. Alikhanyan National Laboratory, Armenia; D. Pokhsraryan,A. Alikhanyan National Laboratory, Armenia L.Kazliner, Alikhanyan National Laboratory, Armenia

  2. “CUBE” Scintillation Detector Assembly

  3. Inside located scintillation detector “THICK” 20 cm thickness scintillator 0.25 sq. meter area. 20% efficiency of neutral component registering. Detection threshold approximately 5 MeV.

  4. Surrounding scintillation detectors “THIN” 1 cm thickness scintillator, 1 sq. meter area. 3% efficiency of neutral component registering. 98% efficiency of charged component registering. Detection threshold approximately 1 MeV.

  5. Light collection scheme realized by means of fiber optics.

  6. Logic for Neutral Component Separation

More Related