1 / 8

Sixth Workshop of National Reference Laboratories for Parasites

Sixth Workshop of National Reference Laboratories for Parasites Istituto Superiore di Sanità, Rome, Italy, 23-24 May, 2011. 1 th Proficiency test on. “ Trichinella larvae identification at species level by a molecular method”. Introduction.

nelia
Télécharger la présentation

Sixth Workshop of National Reference Laboratories for Parasites

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sixth Workshop of National Reference Laboratories for Parasites Istituto Superiore di Sanità, Rome, Italy, 23-24 May, 2011 1th Proficiency test on “Trichinella larvae identification at species level by a molecular method”

  2. Introduction • The PT was organized to satisfy the request of some NRLs to be evaluated about their ability to identify Trichinella muscle larvae at species level; • 18 NRLS agreed to participate.

  3. Materials and methods Total samples 4 Total samples 20 No particular restriction regarding molecular technique was established.

  4. Results

  5. Results • 9 laboratories analyzed pool of larvae; • 4 laboratories analyzed single larvae; • 1 laboratory analyzed both pool and single larvae; • 4 laboratories did not send their results; • Different DNA purification protocols were used; • Almost all laboratories used the multiplex PCR protocol to identify samples, only 1 laboratory amplified and sequenced a portion of the 5S rDNA; • All laboratories that analyzed pool of larvae were able to obtain PCR products; • 4 laboratories that analyzed single larvae failed to obtain PCR products from a number of samples between 4 and 15 (20%-75%); • 4 laboratories failed the species identification.

  6. Single larvae analysis Reported problems (P), possible causes (C) and suggestions (S) • P: Loss of larva during its transfer from ethanol to water (or PBS) before the analysis. • C: The dried larva tends to float on water surface or to stick to the tip. • S: Transfer the larva directly to the test tube using few volume of ethanol (1-2 µl) and wait the evaporation of the ethanol before starting the DNA purification procedure. • P:Low concentration DNA templates for PCR. • C: The DNA purification method is not enough sensible to be used on single larvae (i.e. kit based on columns with a final elution volume of 200 µl). • S: Use kit based on magnetic beads (more sensible) and decrease the elution volume to 50-80 µl. • P: Non-specific PCR products. • C: The DNA is not enough purified; unbalanced primers mix; reagents quality. • S: Use commercial kit (better if based on magnetic beads) to purify DNA instead of home made method; check and accurately balance the primers set in the multiplex; use a good Taq polymerase (better if hot start).

  7. Conclusions • The mistakes in Trichinella larvae identification observed in this PT were mainly due to the use of not suitable diagnostic tools or protocols and to the lack of appropriate training (mainly concerning single larvae analysis).

  8. Thanks for your attention