1 / 25

Welcome to Hardie 101 Basic Training Best Practices Version 6.2 – October 2012

Welcome to Hardie 101 Basic Training Best Practices Version 6.2 – October 2012. By: Gary Griffiths Senior Installation Specialist James Hardie Installation Team. Products & Installation. Installation Best Practices 6.2. New Hardie Shingle. Please Follow Along in the Best Practices:.

nelly
Télécharger la présentation

Welcome to Hardie 101 Basic Training Best Practices Version 6.2 – October 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Welcome to Hardie 101 Basic Training Best Practices Version 6.2 – October 2012 By: Gary Griffiths Senior Installation Specialist James Hardie Installation Team

  2. Products & Installation Installation Best Practices 6.2

  3. New HardieShingle Please Follow Along in the Best Practices: Pages 94 – 105 in the US HZ5 Best Practices Guide Version 7.0 Pages 97 – 106 in the US HZ10 Best Practices Guide Version 7.0 Pages 77 – 86 in the Canada HZ5 Best Practices Version 6.2

  4. New HardieShingle New HardieShingle Product Description What is HardieShingle? HardieShingle siding is fiber-cement shingle for sidewall applications. HardieShingle siding is available as Straight-Edge Panels (48-in. long by 15.25-in. high) or Staggered-Edge Panels (48-in. long by 15 7/8”-in. high). HardieShingle panels also come as Decorative Half-Round Shingles in some markets. For smaller coverage areas, Individual Shingles are also available in 4.2”, 5.5”, 6.75”, 7.25” & 10”widths. Please see your James Hardie dealer for local availability of these products. HardieShingle siding is available as a prefinished James Hardie product with ColorPlus Technologyor in our PrimePlus Technology, Engineered for Climate. All HardieShingle product is installed with a 7”-in. reveal (exposure). See your local dealer for details and availability of products, colors and accessories.

  5. New HardieShingle New HardieShingle Product Options NEW Staggered-Edge HardieShingle Panel Half-Road HardieShingle Panel NEW Individual HardieShingle NEW Straight-Edge HardieShingle Panel

  6. New Individual HardieShingle New Individual HardieShingle Siding Did You Know? New Individual HardieShingleProduct Info – • So What’s NEWabout the New Individual HardieShingle: • Now available in Primed & ColorPlus • New Texture • Nail Line • Height, Width, & the Distribution of Widths 7” Exposure 15.25” Overall Height • Individual HardieShingle is now packaged in 2 sq. increments • Now available for purchase in 1/3 sq. increments • *See local JH Supplier for details

  7. New Individual HardieShingle New Individual HardieShingle Siding Did You Know? • 15 pieces per bundle • (Wrapped in Plastic) New Individual HardieShingle - Packaging& Pallet Layout (Plan View) • Two layers of • (plastic wrapped) bundles per pallet • 7 bundles per row • (105 pieces) • or • 1/3rd of a square (33.3 sqft) • 630 pieces or 2 squares (200sqft) per pallet

  8. New Individual HardieShingle Installation of New Individual HardieShingle Siding Did You Know? General HardieShingle Installation Info – • Like conventional cedar wood-shingle siding, HardieShingle requiresthe use of a starter strip and a starter course before installing the first full course of shingle panels or individual shingle. • The starter strip establishes the proper angle of the first course of shingle on the wall, and the starter course provides solid backing and keyway coverage for the first shingle course. ¼” Max. • Also just like conventional cedar wood-shingle siding, HardieShingle is installed with a 7 in. exposure (reveal). 7” • When Installing Individual HardieShingles be sure to space shingles no more than a 1/4” in. apart. (A Carpenters Pencil works Great) • Spaces between shingles should be offset by 1¼” (measured from outside edge of keyway to outside edge of keyway) between the courses above and below.

  9. New Individual HardieShingle Installation of New Individual HardieShingle Siding - Step by Step - Installation Procedure – 2 • Begin by Installing the Starter Strip. Make sure thebottom edge of the Starter Strip is FLUSH with the mud sill orthe bottom edge of the exterior sheathing. • The Starter Strip should be Installed over the weather-resistive barrier. • Starter Strips can be made by ripping 1 ¼” strips from full or partial HardiePlank or the top portion of the HardieShingle Panels. 3a 8 in. Measure up 8”-in. from the bottom of the starter strip, and snap a chalk line • Install the Starter Course, keeping the top edge of the Starter Course on the chalk line. • 3a. Use 8 ¼”HardiePlank Lap Siding for the Starter Course. • Optional* The Top portion of the HardieShingle Panel may be ripped down to 8 ¼”and used as a starter course. 1

  10. New Individual HardieShingle Installation of New Individual HardieShingle Siding - Step by Step - Installation Procedure Continued – • Measure up 7”-in. from the top of the Starter Course and snap your next chalk line. These chalk lines should continue up the wall in 7”-in. increments for successive courses. • Every Four (4) courses or so you should check to make sure the shingles are level, & running straight on the wall. ¼” Minimum of 1 ¼” Keyway Stagger –Measured from (Outside Edge to Outside Edge) Install in a Random configuration 1 ¼” • The First Course of Individual HardieShingle is then Installed even with the bottom edge of the Starter Course. • Make sure you keep a consistent ¼”-in. space at each keyway (no greater) & a min. of an 1 ¼” Keyway Stagger on the exposed 7”-in. HardieShingle face. • Vary the sizes of the Individual HardieShingle to achieve a random look to the installed HardieShingle. 7” 7”

  11. New Individual HardieShingle Recommended Fasteners for New Individual HardieShingleSiding Fastener Specifications – • The Recommended Fastener for Fastening New Individual HardieShingle is an (11 ga) 0.121” x .371” x 1.25”Corrosion Resistant Roofing Nail. • An .091” x 221” x 1.5”Siding Nail may also be used into a Min. 7/16” APA Rated Exterior Sheathing.

  12. NewHardieShingle Panel NewHardieShingle Staggered Edge Panel NewHardieShingle Straight Edge Panel

  13. New HardieShingle Panel New HardieShingle Panel Did You Know? HardieShingle Panel Product Info – • So What’s NEWabout the New HardieShingle Panel: • Five (5) different shingle widths instead of seven (7) • Nail Line Location vs. Text Location • Reduced Waste when combined with Individual HardieShingle 7” Exposure 15.25” Overall Height Nail Line HardieShingle Text HardieShingle Straight Edge Panel HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HardieShingle Individuals - - - - - - - - - - - - - - - - - - - - - - - • 15.25” Tall just like Individuals & 48” Wide. • Installed with a 7” Exposure • Increased Install Speed & Efficiency when both HardieShingle Panels & Individuals are used together. 48” 48” Panel Width

  14. New HardieShingle Panel New HardieShingle Panel Did You Know? New HardieShingle Panel - Packaging& Pallet Layout • So What’s NEWabout the New HardieShingle Panel Packaging: • HardieShinglePanels are packaged in 2sq (200sqft) increments • Two Panel Designs on the same pallet (“A” Panel & “B” Panel) • The ability to go up to 7 courses without the pattern repeating 200 SqFt of Wall Coverage per Pallet HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 “A” Panel - - - - - - - - - - - - - - - - - - - - Mirror Images of Each Other HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 HardieShingle HZ5 Up to 7 Courses without a repeatable pattern “B” Panel - - - - - - - - - - - - - - - - - - - -

  15. New HardieShingle Panel Installation of New HardieShingle Panel Did You Know? General New HardieShingle Panel Installation Info – • HardieShingle Panels just like our individual shingles, requiresthe use of a starter strip and a starter course before installing the first full course of shingle panels. • HardieShingle Straight Edge Panel is installed with a 7 in. exposure & Staggered Edge a 6 in. exposure (Measured from the top edge to the top edge of the HardieShingle Panel) 7” 1 ¼” Min. • Fasteners going into just a min. 7/16” APA rated Exterior Sheathing must be installed no greater than 13 ¾” in. apart. • Fasteners are secured through the HardieShingle Panel on the Embossed Nail-line located just above the keyways. (through top panel and through top edge of lower shingle panel) • Offset the HardieShingle keyways from course to course by a minimum of 1 ¼”(measured from outside edge of keyway to outside edge of keyway) between the courses above and below.

  16. NewHardieShingle Panel Installation of New HardieShingle Panel (Direct To Stud Application) - Step by Step - Installation Procedure – • Just like the Individual HardieShingle installation process, begin by Installing the Starter Strip. Thebottom edge of the Starter Strip should be FLUSH with the mud sill orthe bottom edge of the exterior sheathing. • The Starter Strip should be Installed over the weather-resistive barrier. • Starter Strips can be made by ripping 1 ¼” strips from full or partial HardiePlank or the top portion of the HardieShingle Panels. 2 3a 8 in. Measure up 8”-in. from the bottom of the starter strip, and snap a chalk line • Install the Starter Course, keeping the top edge of the Starter Course on the chalk line. • 3a. Use 8 ¼”HardiePlank Lap Siding for the Starter Course. • Optional* The Top portion of the HardieShingle Panel may be ripped down to 8 ¼”and used as a starter course. 1

  17. NewHardieShingle Panel Installation of New HardieShingle Panel (Direct To Stud Application) - Step by Step - Installation Procedure Continued – • Measure up 7”-in. from the top of the Starter Course and snap your next chalk line. These chalk lines should continue up the wall in 7”-in. increments for Straight Edge HardieShingle Panel. 4a. **Measure up 6”-in. from the top of the Starter Course if Installing Staggered Edge HardieShingle Panel. • Measure and Cut the First HardieShingle Panel to make sure the end of the panel falls Over Framing. • Keep the bottom edge of the first panel flush with the bottom edge of the corner trim. • Make sure you leave a min. 1/8” gap for the 3/8” bead of permanently flexible caulking to be applied between the HardieShingle Panels & the Trim. • Using the Chalk lines snapped in step 4 - position panels along the first course and secure with suitable fasteners & spacing for your application into the framingas noted in the ESR 1844 & 2290 Reports. TIP:A Straight Edge Panel can be used on the bottom course if desired 7 in. ¼” • Next, Measure & Cut the First Panel for the Second Course, making sure it lands on a stud, (keep all your cut edges against the trim, factory edges in the field ALWAYS). • Make sure you have a min. 1 ¼” keyway stagger from the shingles below. Minimum of 1 ¼” Keyway Stagger 1 ¼”

  18. NewHardieShingle Panel Installation of New HardieShingle Panel - Step by Step - Installation Procedure – Direct to Min. 7/16” APA Rated Exterior Sheathing Snap a Line at the Center of the Wall.Measure 16”-in. to the Left&16”-in. to the Right and snap two more vertical lines. Always work from center of wall to the outside corner trim. Just like the HardieShingle Panel Direct to Stud Application, Cut and Install the 1.25”-in. starter stripand the 8.25”-in. starter course. Snap your horizontal layout lines. 6”-in. for Staggered Edge Shingle Panel, and 7”-in. for Straight Edge Shingle Panel.(Refer to the “Direct to Stud” installation for specifics.) Install the First Shingle Panel, Left Factory Edge to the Left Vertical Snapped Line. Infill the remaining Shingle Panels on either side of the First Panel Installed. All butt joints in the field MUST be Factory Edge to Factory Edge. All Cuts go Towards the Trim. TIP:Refer to ESR-2290 for allowable wind loads TIP:Panels & Individuals may be mixed together to reduce waste and save time. Install the First Shingle Panel on the Second Row with the Left Factory Edge to the Center Line. Infill the remaining Shingle Panelson either side of the First Shingle Panel Installed. Again, Keeping Factory Edge to Factory Edge. 2 3 4 5 6 1 Continue the Same Process for the Third Row. Left Factory Edge to the far Right Vertical Line. Make sure the First Shingle Panels Keyways of each course are Staggered by at least 1.25”-in. Repeat Starting Panel on remaining rows using Left, Middle, Right layout lines. 1 ¼”

  19. NewHardieShingle Panel Installation of New HardieShingle Panel - Step by Step - Installation Procedure – Direct to APA Rated Ext. Sheathing - GABLES Step 3 Step 2 Step 1 Install 8.25” Starter Course - Snap Horiz. Chalk Line at 15.25” up from bottom of Starter Course. Snap (3) Chalk Lines – Center, 16” to the Left, & 16” to the Right. Rip & Install an 1.25” Starter Strip – Don’t Forget the 2” Roof Line Clearance. Step 4 Step 5 First Row Starts with Left Factory Panel Edge to Left Line- Infill remaining Panels – Snap Horiz. Chalk Line 7” above the First Row. (6” for Staggered Edge Shingle) Second Row Starts with Left Factory Panel Edge to Center Line – Infill remaining Panels – Snap Horiz. Lines 7” up the Gable for successive courses. (6” for Staggered Edge Shingle) TIP: Use HardieShingle Panels in the Main Body of the Gable – Use Individual HardieShingle Up the Rake to Reduce Waste & Save Time.

  20. NewHardieShingle Panel Recommended Fasteners for New HardieShingle Panel Fastener Specifications – • The Recommended Fastener for Fastening New HardieShingle Panel is a 0.083” x .187” x 1.5”Corrosion Resistant Ring Shank Nail.

  21. NewHardieShingle Panel APA Rated Exterior Sheathing Fastening Pattern Overview

  22. New HardieShingle Installation Requirements Please Reference the Installation Requirements found on: Pages 100 – 105 in the US HZ5 Best Practices Guide Version 7.0 & Pages 102 – 106 in the US HZ10 Best Practices Guide Version 7.0 & Pages 81 – 86 in the Canada HZ5 Best Practices Version 6.2

  23. Begin the HardieShingle Installation Requirements Knowledge Test Installation Best Practices 6.2

  24. KNOWLEDGE TEST RESULTS HardieShingle Installation Requirements: What material is appropriate to make a starter course from? (check all that apply) Lap Siding Vented Soffit Individual Shingles Shingle Panel When Laying out the wall to install HardieShingle Panel what is the first thing you need to do? Find the center of the wall and snap a vertical line. Start at the far left with your first shingle panel. Install a starter course. Install a starter strip. A starter strip and starter course is required when installing HardieShingle? True False A full headed nail must be used to install HardieShingle panels? True False When installing HardieShingle to APA rated sheathing, nails must be placed no greater then what spacing? 6” o.c. 8” o.c. 12” o.c. 13 ¾” o.c. When installing HardieShingle Panel it is important to always work from the center of the wall out? True False

  25. General Installation Requirements 12 Critical Details to a Quality Installation • Page 13 in your Best Practices Guide. • All 12 items are Critical to the Long Term Quality, Durability and Installation Compliance. • Most Important Page in your Best Practices Guide

More Related