An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MSU Paducah Towing Vessel Bridging Program LTJG Sam Hatch Marine Safety Unit Paducah, Towing Vessel Bridging Program

  2. District 8 Towing Vessel Statistics • 3,797 Vessels in D8 • Decals Issued in D8 – 1600 • 41% of D8 Fleet Decaled

  3. MSU Paducah Exam Numbers • 6th Largest Fleet of any D8 Unit! • 10% of all D8 Decals Issued in Paducah! • Industry Initiated Exams – 171 • Decals on Vessels in Fleet- 164 • Percent of Fleet with Decal – 55%

  4. Common Exam Discrepancies • Fuel Shut Offs (46 CFR 27.207) • Fuel Shut-Off Missing • Fuel Shut-Off not working Properly • Valve not located near the source of supply • Improper Location of Fuel Shut-Off remote • Improper Labeling of Remote Used with Permission of Ingram Barge Company

  5. Common Exam Discrepancies • Fire Pump (46 CFR 27.301) • Remote/Local Switch to energize fire pump is in wrong location or not working • Pump does not work • Inadequate water pressure Used with Permission of American Commercial Lines

  6. Common Exam Discrepancies • General Alarm (46 CFR 27.201) • General Alarm System Missing • Supplemental red light in noisy area is missing • Red light is not visible on all decks of engine room • Required sign is missing Used with Permission of American Commercial Lines

  7. Common Exam Discrepancies • Fire Detection System (46 CFR 27.203) • Professional Engineer Letter • Non-CG Approved System • System not Operational Used with Permission of American Commercial Lines

  8. Common Exam Discrepancies • Fixed Piping for Oily Mixtures (33 CFR 155.410) • No Fixed Piping System • No Stop valve at required position • No Discharge point on weather deck Used with Permission of American Commercial Lines

  9. Common Exam Discrepancies • B-V Semi-Portable Fire Extinguisher (46 CFR 27.303) • Not on board • Lack of Maintenance Used with Permission of American Commercial Lines

  10. The Way Forward • Ongoing Outreach Efforts • Encouraging Industry Initiated Exams • Awaiting NPRM Publication • Encouraging Comments on upcoming NPRM