1 / 58

Spettrometria di massa

Spettrometria di massa. Separazione di ioni in fase gassosa in funzione della loro massa molecolare Analisi di frammenti che si generano per attivazione e selezione di un singolo ione. Spettrometro di massa. Rivelatore. Sorgente. Analizzatore. m/z. Sorgenti. Ionizzazione diretta EI, CI

niran
Télécharger la présentation

Spettrometria di massa

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Spettrometria di massa • Separazione di ioni in fase gassosa in funzione della loro massa molecolare • Analisi di frammenti che si generano per attivazione e selezione di un singolo ione

  2. Spettrometro di massa Rivelatore Sorgente Analizzatore m/z

  3. Sorgenti • Ionizzazione diretta • EI, CI • Desorbimento • FAB • MALDI • Nebulizzazione • ESI

  4. Ionizzazione diretta

  5. MS & Proteomics

  6. Spettro ESI del Tripsinogeno (MW 23983) M + 15 H+ 1599.8 M + 16 H+ M + 14 H+ 1499.9 1714.1 Relative Abundance M + 13 H+ 1845.9 1411.9 1999.6 2181.6 m/z Mass-to-charge ratio

  7. 1599.8 1499.9 1714.1 1845.9 1411.9 1999.6 2181.6 Calcolo accurato della massa (MR = 23983 Da) • (M+n+3)/(n+3) = 1499.9 • (M+n+2)/(n+2) = 1599.8 • (M+n+1)/(n+1) = 1714.1 • (M+n)/n = 1845.9 n = 13 • (M+16)/16 = 1499.9  23982.4 • (M+15)/15 = 1599.8  23982.0 • (M+14)/14 = 1714.1  23983.4 • (M+13)/13 = 1845.9  23983.7

  8. Quadrupolo Uses a combination of Radio Frequency(RF) and Direct Current(DC) voltages to operate as a mass filter. • Has four parallel metal rods. • Lets one mass pass through at a time. • Can scan through all masses or sit at one fixed mass.

  9. Matrix Assisted Laser Desorption (MALDI)

  10. Matrix Assisted Laser Desorption (MALDI)

  11. Schema esemplificato del processo di ionizzazione MALDI

  12. time-of-flight (TOF) Ion Source Flight Tube 20-25 kV Detector Principle: If ions are accelerated with the same potential at a fixed point and a fixed initial time and are allowed to drift, the ions will separate according to their mass to charge ratios.

  13. time-of-flight (TOF) Ion Source Flight Tube Detector The ions enter the flight tube with the lighter ions travelling faster than the heavier ions to the detector

  14. time-of-flight (TOF) Ion Source Flight Tube Detector The lighter ions strike the detector before the heavier ions. This “time of flight” (TOF) can be converted to mass

  15. MALDI/TOF MASS SPECTROMETRY

  16. 40000 30000 20000 10000 0 Spetto MALDI/TOF di IgG MH+ Relative Abundance (M+2H)2+ (M+3H)3+ 50000 100000 150000 200000 m/z

  17. Mass Analyzers

  18. Risoluzione e sensibilità

  19. Risoluzione MALDI

  20. Peptide mass fingerprinting

  21. Limiti del peptide mass fingerprinting • La proteina non è presente nel database • La proteina è ricca di modificazioni co/post-traduzionali • Lo spot nasconde più di una proteina

  22. Mass spectrometer LC Fraction collector 0.18mm X 15cms C18 column 7:1 flow split 4µl/min La sorgente ESI può essere collegata all’uscita di un sistema di separazione 400nl/min Further MS analysis

  23. MS/MS

  24. m1 m2 m4 m3 m2 m1 m4 m3 mass scanning mode m1 m2 m2 m2 m2 m2 m4 m3 single mass transmission mode Quadrupolo

  25. Tandem MS

  26. MS/MS

  27. Frammentazione dei peptidi

  28. LC-MS-MS

  29. Isotope-coded affinity tagging

  30. ICAT

  31. ICAT

More Related