1 / 12

DVPSCM12

DVPSCM12. Agenda. What is SCM Serial Port solution Application area Function Software. Requirement I. Q1: In my huge system, I need many Modbus serial devices, but one RS-485/422 port can only connect to 32 devices. What can I do?. PLC. PLC. PLC. PLC. PLC. PLC. …. TC. TC. VFD.

noreen
Télécharger la présentation

DVPSCM12

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DVPSCM12

  2. Agenda • What is SCM • Serial Port solution • Application area • Function • Software

  3. Requirement I Q1: In my huge system, I need many Modbus serial devices, but one RS-485/422 port can only connect to 32 devices. What can I do? PLC PLC PLC PLC PLC PLC … TC TC VFD ASDA ASDA VFD … TC ASDA VFD VFD VFD

  4. Requirement II Q2: When there are sensors, meters, UPS or PLCs, frequency inverters connected in a system but of different communication formats, what can I do? PLC PLC … 電表 讀卡機 按鈕 TC VFD ASDA

  5. Requirement III Q3: When the RS-232/RS-485 port on a PLC is connected with some device but I still need to modify or re-download the PLC program, what can I do? ? PLC RS-485 RS-232 TC ASDA VFD

  6. Requirement IV Q4: When a PLC is connected to many frequency inverters and servos, and the RS-485 signals are interfered that leads to malfunction, what can I do? ASDA ASDA VFD VFD VFD VFD

  7. DVPSCM12-SL 2011Delta Serial communication solution 2011/05

  8. DVPSCMSerial port solution Q1: In my huge system, I need many Modbus serial devices, but one RS-485/422 port can only connect to 32 devices. What can I do? Q2: When there are sensors, meters, UPS or PLCs, frequency inverters connected in a system but of different communication formats, what can I do? Max. 8*2*32=512 devices Using UD Linkto connect all RS-485device Q3: When the RS-232/RS-485 port on a PLC is connected with some device but I still need to modify or re-download the PLC program, what can I do? Q4: When a PLC is connected to many frequency inverters and servos, and the RS-485 signals are interfered that leads to malfunction, what can I do? PLCCOM3 Strong Noise Resistance

  9. DVPSCM12-SL Max. 8 DVPSCM12-SL modules are extendable from DVP-PLC … • Only one PLC is needed. Cost is saved by left-side extensions. • Every DVPSCM12-SL has 2 serial ports, every port can be RS-422 or RS-485. • Every port is connectable to 32 serial communication devices, supporting max. 460,800 bps • Every port has full isolation between communication and power supply, built-in with 120Ω termination resistor and switches. • Supports slave mode. Can be the COM3 for PLC program upload/download. • User-defined communication (UD Link) connects to special communication formats of other brands. • Applicable PLCs: DVP-SV, DVP-SX2, DVP-SA2, DVP-EH2-L

  10. DVP12SCM-SL Through RS-232 or Ethernet Standard Modbusprotocol  Modbus Advance DCISoft PLC … TC VFD Special communication format  UD-Link … Power meter Card Reader Other device

  11. Application area- BA … Power meter Sensor IBLM UPS

  12. Application area - FA • Using DVPSCM to connect RS-485 device • Central SCADA use DELTA Ethernet module to control local device Remote monitor Local control