THERMOSTAT. REFRIGERATION AND AIR CONDITIONING TECHNICAL SKILL PROGRAM SMKN 1 CIREBON Visit us on : ptu.smkn1-c i r e b on .sch.id. CONTOH GAMBAR THERMOSTAT.

norman
Télécharger la présentation

THERMOSTAT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. THERMOSTAT • REFRIGERATION AND AIR CONDITIONING TECHNICAL SKILL PROGRAM • SMKN 1 CIREBON • Visit us on : ptu.smkn1-cirebon.sch.id

  2. CONTOH GAMBAR THERMOSTAT

  3. Thermostat adalahalat yang digunakanuntukmenjagatemperatur evaporator/ruangtetapberadapadabatas yang direncanakandengantepat.

  4. BAGIAN-BAGIAN THERMOSTAT

  5. Kebanyakan thermostat menggunakan bulb sebagai sensor suhu. Ketikatemperaturnaik, thermostat akanmenutupkontaknya, sedangkanjikatemperaturturun thermostat akanmembuka • Perubahansuhutersebutdapatmenyebabkan gas, uapataucairan di dalampipadan bulb mengembangataumenyusut, sehinggadapatmenimbulkantekananpada bellow (diafragma) yang berubah-ubah.

  6. Setting Thermostat • Thermostat mempunyaibatas cut in dan cut out tertentu. • Perbedaanantarabatas cut in dan cut out tergantungdaripengaturandifferensialnya. • Besarkecilnyadifferensialtergantungpadapenggunaandanlokasialat sensor suhu (bulb). • Pengaturanthermostat ada 2 macam : • pengaturanrange dan • pengaturandiferential

  7. Pengaturan Range • Mengaturrange adalahcarapengaturan cut in dan cut out thermostat yang menghasilkandaerahpengaturan. • Biasanyapadabautpengaturan range adapetunjukarahputaranbautpengatur range yang memberikanpengaturansebagaiberikut : • Memutarbautsearahjarum jam - suhukerjanaik • Memutarbautrange melawanjarum jam - suhukerjaturun • Memutarbaut range satuputaranakanmengubahsuhukerjaantara 5o C - 8oC

  8. PengaturanDiferential • Batas temperaturmenjalankanmotor kompresorpadasaattemperatur evaporator naikpadatitiktertinggisesuaipengaturannyadisebut"Cut in" • Sedangkanbatastemperaturuntukmenghentikan motor kompresorsaattemperatur evaporator mencapaititikterendahsesuaipengaturannyadisebut"Cut out". • Jadidiferentialadalahperbedaantemperaturantaratitik cut in dantitik cut out. • Dalammengaturdiferential, tidakbolehterlalukecilataupunterlalubesar. • Jikaterlalukecildapatmenyebabkan short cycle. • Short cycle adalahselangwaktu cut inidan cut out yang sangatsingkatsehinggakerjakompresorterputus-putuskarenahalinidapatmerusakkompresor. • Namunbilaperbedaaniniterlalubesarmakatemperaturpendinginanakanmeningkatmenjaditinggisebelumterjadi cut in.

  9. Mekanismekerja thermostat a. Temperaturnaik Compressor contact on Cairan di dalam sensing bulb menjadi gas Padasaattemperatur evaporator naikmelebihibatas yang diinginkanmakatemperatur bulb juganaiksehinggacairan di dalam bulb akanberubahmenjadi gas. Akibatperubahanini, tekanan di dalam bulb juganaiksehinggamendorong bellow untukmengembang. Karenatekanan bellow lebihbesardaritekananpegasmakaakanmendorong movable contact untukterhubungdengan stationary contact sehinggaakanmenyalakan compressor. Ketikacompressor menyala, makarefrigeranakankembalibersirkulasidanmasukke evaporator kembalisehinggaakanmenurunkantemperatur evaporator.

  10. Mekanismekerja thermostat b. Temperaturturun Compressor contact off Gas di dalam sensing bulb menjadicair Ketikatemperatur evaporator turunmelebihibatas yang diinginkanmakatemperatur bulb jugaturunsehingga gas di dalam bulb akanberubahmenjadicair. Akibatperubahanini, tekanan di dalam bulb jugaturunsehinggamendorong bellow untukmengkerut. Karenatekanan bellow lebihkecildaritekananpegasmakaakanmendorong movable contact untukterpisahdengan stationary contact sehinggaakanmematikan compressor. Ketikacompressor mati, makarefrigeranberhentibersirkulasisehinggatidakadarefrigeran yang masukke evaporator sehinggaakanmenaikkantemperatur evaporator.

  11. Mekanismekerja thermostat a. Temperaturnaik

  12. Mekanismekerja thermostat b. Temperaturturun