1 / 7

Hot-Wall Furnace Heating

Hot-Wall Furnace Heating. Modeling of Semiconductor Process Equipment. Introduction. Furnace reactors are used in the semiconductor industry for layer growth and annealing The susceptor is heated by a RF coil to high temperatures

nyla
Télécharger la présentation

Hot-Wall Furnace Heating

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hot-Wall Furnace Heating Modeling of Semiconductor Process Equipment

  2. Introduction • Furnace reactors are used in the semiconductor industry for layer growth and annealing • The susceptor is heated by a RF coil to high temperatures • A uniform distribution of the temperature at the wafer region is crucial for controlled and reproducible process steps • This model investigates the temperature in a hot-wall furnace reactor used for silicon carbide growth

  3. Model Definition – Geometry • Symmetry can be used to cut the 3D geometry in half twice • The graphite susceptor is surrounded by a graphite felt insulation, a quartz tube, and the RF coil

  4. Model Definition • This is a multiphysics model, solving an electromagnetic part and one thermal part • The electromagnetic part solves for the magnetic vector potential, A, at a fixed frequency • The thermal part solves for temperature, T, and radiation • The radiation fully controls the thermal flux between the susceptor and the quartz tube

  5. Results • The temperature on the quartz tube has a maximum of about 900 K, which may be a bit too high

  6. Results • The heating cycle takes about one hour, and with a power of about 10 kW the temperature at the center of the wafer reaches almost 2300 K

  7. Results • A surface plot of the wafer reveals the nonuniformity in temperature at the end of the heating cycle, which is almost 150 K