Equipment and Aseptic Technique

Equipment and Aseptic Technique. Helping our cells grow. Automatic Pipet. Pipettor or Pipet-Aid used for transferring large volumes of liquid (1-50mls) Important not to draw liquid up into the pipettor. Sterile serological pipets. Individually wrapped Multiple sizes

Télécharger la présentation

Equipment and Aseptic Technique

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Equipment and Aseptic Technique Helping our cells grow

  2. Automatic Pipet • Pipettor or Pipet-Aid • used for transferring large volumes of liquid (1-50mls) • Important not to draw liquid up into the pipettor

  3. Sterile serological pipets • Individually wrapped • Multiple sizes • Numbered along the sides • Be sure numbers face you when putting pipet into pipettor

  4. Tubes, bottles • Various sizes • Some plastic, some glass • Loosen caps before starting to work in the hood

  5. Micropipettor • For dispensing small volumes of liquid • 1-1000ml • Different pipettors dispense different ranges of liquid • Always use a disposable tip with the micropipettor

  6. What is a microliter? • In the metric system, used by all scientists • 1 gram is the weight of a cube of water that measures 1cm3—this volume is 1milliliter • 1 liter (l) =1000 milliliters (ml) • 1 milliliter (ml)=one-thousandth of a liter =0.001 l =1 x 10-3 l • 1milliliter =1000 microliters (ml) • 1 microliter (m l)=one-millionth of a liter (l) =0.000001 l =1 x 10-6 l • 1 microliter (ml)= one-thousandth of a milliliter (ml) = 0.001ml = 1 x 10-3 ml

  7. Culture Dishes (plates) and Flasks • Flasks • Capped vessels • Prevent spills • Well-plates • Multiple areas for experiments with multiple variables • Different sizes available • Dishes • Easy to manipulate cells • Easier to spill or contaminate

  8. “Invisible” life forms are everywhere! • Present on skin, fall off of hair, clothing, in saliva, tears, breath. • Present on surfaces and in water • Especially warm water

  9. Micro-organisms • Bacteria • Most are harmless to us • Cell culture media will help them grow • Bacteria will compete for nutrients in media • Fungi • Mold, yeast • Float in air and are on surfaces bacteria yeast mold

  10. More microoganisms • Viruses • Enter into cells and destroy them in their quest to replicate • Mycoplasma • A bacteria that is hard to discover and hard to get rid of. Viruses-transmission Electron microscopy Mycoplasm-scanning electron microscopy

  11. Sterile vs. Aseptic • Sterile: No life at all (bacteria, fungi, viruses) • Hard to keep an area perfectly steril • Aseptic: Reduced numbers of life forms • Most equipment and reagents provided to you comes sterile • gamma irradiation • autoclaving • High temperature and high pressure steam • filtration

  12. Controlling microorganism growth • The goal: Prevent microbial contamination • Simple, common sense guidelines • Handwashing, using 70% ethanol to clean all items being used near cells • Additives to media • Antibiotics • Antifungals

  13. Biosafety Cabinet • Laminar Flow hood • HEPA filtered air • Air blown down the back of the hood and then across the surface • Aseptic area • Must be wiped clean before and after use

  14. Aseptic Technique • work in culture hood • roll back long sleeves, no rings, watches, bracelets, etc • hair pulled back, caps off • wash hands with antibacterial soap, spray down with 70% ethanol • wash all surfaces with 70% EtOH • don’t cough, talk, sneeze, sing into hood, no eating or gum chewing • lids on bottles when not in use • sterile tips: change if they touch anything other than media. • Keep serological pipets IN hood while working with them…don’t swing them out when you turn around to ask your partner questions. • back surface of hood is cleanest

  15. CO2 incubator • maintains CO2 level (5-10%), humidity and temperature (37o C) to simulate in vivo conditions.

  16. Water bath • To warm media, TRED and PBS before placing on cells • Can harbor fungi and bacteria, • spray all items that were in the waterbath with 70% ethanol before placing in the hood.

  17. Vacuum pump • For permanent aspiration of liquids (media, PBS and TRED). • Use unplugged glass pasteur pipets, throw into sharps box when done.

  18. Inverted Phase Microscope • A phase contrast microscope with objectives below the specimen. • Creates contrast in a sample without staining it. • Staining cells will kill them.