Hg Microwave Ion Clock Technologies for Fundamental Physics in Space John Prestage JPL, Pasadena

Hg Microwave Ion Clock Technologies for Fundamental Physics in Space John Prestage JPL, Pasadena. In Lab: Sang Chung Thanh Le Robert Tjoelker Eric Burt Rob Thompson Nan Yu John Prestage. Flight Design: Armond Matevosian Saverio D’Agostino Eric Archer Larry Epp Paul MacNeal

porsche
Télécharger la présentation

Hg Microwave Ion Clock Technologies for Fundamental Physics in Space John Prestage JPL, Pasadena

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hg Microwave Ion Clock Technologies for Fundamental Physics in SpaceJohn PrestageJPL, Pasadena In Lab: Sang Chung Thanh Le Robert Tjoelker Eric Burt Rob Thompson Nan Yu John Prestage Flight Design: Armond Matevosian Saverio D’Agostino Eric Archer Larry Epp Paul MacNeal Talso Chui John Prestage Lamp Exciter Electronics: William Riley

  2. Space Clock Outline 2-3 kg atomic clock,10-16 stability for under $10M Technology Overview Compact physics package layout Reliability for in-space operation Magnetic Design, Shielding Factors Mechanical design for launch vibration

  3. AAA Battery USO Flights Topex Grace Mars Global Surveyor Cassini New Horizons (Pluto)

  4. Graphic 1E-13 GPS Cs GLONASS Cs Galileo Rb (10-13/day drift) GPS Rb ( 10-13/day drift) GP-A H-Maser 1E-14 Galileo Passive H-Maser Aces H-Maser (ISS) 1E-15 JPL Ion Clock (Prototype) ESA NASA/SAO H-Masers 1E-16 0 10 20 30 40 50 60 70 80 Mass of Atomic Clock (kg) Space-Based Clocks (LEO, MEO)** GALILEO Atomic Clocks **Only Atomic Clock to leave Earth Orbit was a pair of Rb clocks on Cassini-Huygens Probe for Doppler Winds measurement in Atmosphere of Titan

  5. Hg microwave Ion clock Physics Overview No Lasers, No Cryogenics, No Microwave cavities No Light Shift ! No gas load, not a gas ‘flow-thru‘ architecture, no consumables 106-107199Hg+ trapped ions Clock Transition: 40,507,347,996.8 Hz No wall collisions, high Q line State selection via optical pumping from 202Hg+; 1-2 photons/s scattered Plasma UV light source is radiation tolerant, PMT’s have flown many times. Ion Shuttling from Quad to Multi-pole, “Reversible, lossless atomic beam” Ions are buffer-gas (Ne) cooled to ~300K Very low tempco - 0.1C temp change only pulls frequency by ~6x10-17

  6. Breadboard Liter Clock Results • Clock stability to 10-15 in 1 liter physics package • Sealed Tube operation with no active pumps (no power required) for more than 2 years, no degradation of signal size.

  7. ~4x10-13/ Cryogenic Cavity Ultra-high vacuum leads to ultra-high Q With cryogenic local oscillator, will deliver 3x10-14/

  8. ~4x10-13/ Ultra-high vacuum leads to ultra-high Q With quartz USO, will eliminate Dick effect degradation with modified trap architecture See: Local Oscillator Induced Degradation of Medium –Term Stability in Passive Atomic Frequency Standards, Dick, Prestage, Greenhall, Maleki

  9. Physics Package Design Summary • Mass of package shown ~1 kg • w/ Ti tube, 2 layers Mu-metal, Mg baseplate, 4 FS lens,.. • Trap layout same size as lab breadboard, • Optical system collection ~ 2x improved, • Additional outer shield + electronics will add 1-2 kg.

  10. Sealed Tube uses getters to maintain Vacuum (No Consumables) Titanium- Titanium Weld VUV Sapphire to Titanium Seal 450 C Rated Titanium-Titanium Welds Trap rods Alumina Ceramic Bake-Out de-gas rate is exponential Tantalum Tubes - Molybdenum Wires Electron Emitter ~ 1 mA @ 1-2 Watts heater

  11. Getter Pumping used in prototype demo (~3 years with no degradation of ion signal) Estimated Lifetime (from typical outgassing and measurable leak rates)  100 yrs/gram of getter material Getter Reservoir 50 grams >50 years Huygens/Cassini MS used Titanium, Molybdenum getter material

  12. Time (in hours) Tube Materials for 400 C Bakeout Improve vacuum 1000-fold Ultra-clean vacuum is essential for clock stability and tube lifetime. Ion lifetime limited by residual gases, eg., Hg+ + H2O  Hg + H2O+ Gettering action not diminished by presence of weak Hg vapor.

  13. …Optical Design…

  14. G10 Thermal Standoff Al Oven Shell Hg Lamp Lamp Holder (Indium Solder) UV Light Source – 202Hg Lamp • Designed, Fabricated Ovenized Hg Lamp exciter following GPS Rb technology.

  15. Sapphire bulb material for longer lifetime • UV Sterilization/ Water purification Industry uses high power Hg UV Lamps • (~185 nm Ozone production) • Bulb Lifetime Problem Identified: Hg reacts with glass SiO2 to form HgO • Light level falls, Hg leaves the vapor, shortens bulb life • Sapphire Material will extend bulb lifetime by 2-4 • Conclusion: Build bulbs from Sapphire

  16. ….Magnetic Design…. 3 layer shields, each 0.020” thick Mount Tube through 2 shields and coil

  17. Reference Magnetic Field (Quantization Axis for Microwave polarization) • Inherently Low magnetic field sensitivity (35x less than Rb) Transverse magnetic field allows Doppler-free probe of Clock and Zeeman transitions

  18. Shielding Factor and Frequency Shift 1 gauss external pulls frequency ~ 10-15 • Measure μ for real single layer shield • (μ de-rated from 80K to 20K) • Enter shields layout in Maxwell field simulator • Apply 1G (80A/m) field along each of 3 axes • Determine SF = Hext / Hin • Single layer Shield Factor ~

  19. 5x10-16 Shielding Factor and Frequency Shift More useful calculation is the clock frequency shift when external field (1 Gauss) is applied These directions are perpendicular to reference field • Can estimate frequency shift at any position inside shields • μ adjusted from 80K to 20K • BC-field= 50 mGauss • Apply 1G (80A/m) field along each of 3 axes • Determine frequency shift vs position (Plotted at right) This leakage is parallel to reference field

  20. …Vibration Design and Test…

  21. Completed Physics Package Vibration Modal Analysis for TRL 6 vib spec • Modal analysis ~3000 mesh points to find resonant frequencies, all above 200 Hz • Loads are based generic random vibration level, 9.2 Grms • Equivalent quasi-static loads • G peak  100 G’s • Factors of safety • Yield factor of safety is 1.25 • Ultimate factor of safety is 1.40

  22. Shake Test for UV Photo-Multiplier Tubes R6354 R7154 O: Original Data R: Retest Data

  23. Summary - Ion Space Clock Teamed with flight engineers (JPL, GPS) to design small Ion clock for in-vacuum operation and vibration hardening __________________________________________________________________________________________________ Tube design based on other space vacuum tubes with 10+ years life ___________________________________________________________________________________________________ Lamp lifetime expected to exceed 10 years with VUV sapphire bulb material ___________________________________________________________________________________________________ 10-15 stability in (2-3 kg) small package feasible (1 ns at ~ 2 weeks autonomous TK)

  24. ICP, Inductively Coupled Plasma Lamp Lighting Industry uses cylindrical coil exciter • Plasma deposition and Ion thruster industries • use planar coil plasma exciter. • Creates uniform plasma region Two turn inductive exciter coil, 1 Amp at ~200 Mhz In vacuum operation, temperature rises to 170 C, higher than in-air optimum by 70 C Thermal base with indium heat conduction at ~60 C Hybrid Planar-Cylindrical Coil