AVOIDING PROBLEMS
160 likes | 186 Vues
Bondbreakers. AVOIDING PROBLEMS. Definition. DEFINITION. A bondbreaker is a material used to prevent adhesion of newly placed concrete and substrate. Most Common Causes of Bondbreaker Problems. Improper Cure of Slab Improper Finish on Slab Insufficient Application of Bondbreaker
AVOIDING PROBLEMS
E N D
Presentation Transcript
Bondbreakers AVOIDING PROBLEMS
Definition DEFINITION • A bondbreaker is a material used to prevent adhesion of newly placed concrete and substrate
Most Common Causes of Bondbreaker Problems • Improper Cure of Slab • Improper Finish on Slab • Insufficient Application of Bondbreaker • Uneven Application of Bondbreaker • Rain on Bondbreaker prior to drying • Not allowing Bondbreaker to completely dry • Hot Weather practices not followed • Improper Mixing This will Cause Panels to Stick
Proper Cure of Slab THIS IS ESSENTIAL: • SLAB MUST BE CURED IMMEDIATELY AFTER FINISHING • USE AN ASTM C-309 CURING COMPOUND SUCH AS AN ACRYLIC • OR BONDBREAKER AS A CURE
Curing of Slab – Option #1 • ACRYLIC or RESIN-BASED CURING COMPOUND • MEETS ASTM C-309 • APPLICATION RATE 200 SQ FT/GALLON
Curing of Slab – Option #2 • USE BONDBREAKER AS CURE COAT • APPLY EVENLY AT 200 SQ FT/GAL
Mixing Water-Based Bondbreaker • EACH DRUM HAS A INTREGAL MIXER • EACH DRUM HAS A MIXING HANDLE PROVIDED • USE SUPPLIED MIXER ONLY • DRUM MUST BE IN STANDING POSITION • MIX FOR MINIMUM OF 3 MINUTES • MIX BEFORE EACH USE (24 HR PERIOD) • ROLLING DRUM IS NOT PROPER MIXING
Coverage Rates • ALWAYS FOLLOW RECOMMENDED APPLICATION COVERAGE RATES • CURE COAT 200 SQ.FT/gallon • 1st bond breaker coat = 400 SQ.FT/GAL • 2nd or additional bond breaker coat = 500-700 SQ.FT/GAL – Applied at right angles
Coverage Rates • POROUS OR ROUGH CONCRETE WILL REQUIRE ADDITIONAL BONDBREAKER • BONDBREAKER RAINED ON PRIOR TO DRYING WILL REQUIRE AN ADDITIONAL COAT.
Tests • PRESENCE OF BONDBREAKER CAN BE CHECKED • SOAPY FEEL TEST: VERIFIES PRESENCE OR BONDBREAKER, BUT NOT NECESSARILY SUFFICIENT COVERAGE • WATER BEAD TEST: WATER THAT READILY BEADS ON THE SURFACE USUALLY INDICATES THE SUFFICIENT PRESENCE OF BONDBREAKER
Hot Weather Practices HOT WEATHER REQUIRES SPECIAL ATTENTION: • HOT WEATHER AIR TEMP > 90o F OR SLAB TEMP > 130oF • FLOOD SLAB TO SSD PRIOR TO APPLICATION OF BONDBREAKER... REMOVE EXCESS WATER.
Weather Considerations • RAIN • RE-COAT IF NECESSARY • HOT / WINDY • INCREASE APPLICATION RATE • COMMENCE CURING IMMEDIATELY • FOG SLAB TO SSD PRIOR TO APPLICATION OF BONDBREAKER • COOL AND DAMP • MAY INCREASE DRYING TIME • MORE LIGHT COATS • ALLOW EACH COAT TO DRY THOROUGHLY
Summary • BONDBREAKERS ARE OFTEN BLAMED FOR PROBLEMS RESULTING FROM POOR PROCESS • ALWAYS FOLLOW RECOMMENDED APPLICATION INSTRUCTIONS • BE AWARE OF WEATHER CONDITIONS • ALLOW EACH COAT TO DRY THOROUGHLY • TEST FOR PRESENSE OF BONDBREAKER • MISUSE OF BONDBREAKER REQUIRES EXPENSIVE REMEDIES • PROPER USE OF BONDBREAKER IS THE MOST CRITICAL PHASE OF TILT CONSTRUCTION
Remember THE COST OF BONDBREAKER IS LOW COMPARED TO THE COST OF ONE STUCK PANEL
Bondbreakers • SPEC TILT WB • CHEMICALLY REACTIVE WATER BASED • SPEC TILT EX • QUICK DRYING, EXEMPT SOLVENT, LOW VOC, SOLVENT-BASED